共 31 条
Prospective Study of the Effect on Gait of a Two-Component Total Ankle Replacement
被引:19
作者:
Choi, Jae Hyuck
[1
]
Coleman, Scott C.
[2
]
Tenenbaum, Shay
[2
,3
]
Polo, Fabian E.
[2
]
Brodsky, James W.
[2
]
机构:
[1] Daegu Vet Hosp, Daegu City, South Korea
[2] Baylor Univ, Med Ctr, Dallas, TX 75246 USA
[3] Tel Aviv Univ, Sackler Fac Med, Chaim Sheba Med Ctr, Dept Orthoped Surg, IL-69978 Tel Aviv, Israel
关键词:
gait studies;
ankle arthritis;
total ankle arthroplasty;
Salto;
ankle replacement;
TERM FOLLOW-UP;
MOBILE-BEARING;
FOOT KINEMATICS;
ARTHRODESIS;
ARTHROPLASTY;
PROSTHESIS;
ARTHRITIS;
OSTEOARTHRITIS;
OUTCOMES;
WALKING;
D O I:
10.1177/1071100713494378
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Background: The purpose of this study was to evaluate the functional outcome as measured by prospective gait analysis of patients undergoing total ankle arthroplasty using a 2-component Salto Talaris total ankle prostheses with a fixed polyethylene bearing. Methods: Twenty-one patients with severe ankle arthritis who underwent unilateral total ankle arthroplasty using a 2-component Salto Talaris device with a fixed polyethylene bearing were studied prospectively. Mean age was 69 years in 16 female and 5 male patients, and mean follow-up was 37.2 (range, 24-50) months. Three-dimensional gait analysis was performed using a 12-camera digital-motion capture system preoperatively and repeated at a minimum of 2 years postoperatively. Temporospatial measurements included velocity, cadence, step length, and support times. Measured kinematic parameters included sagittal plane range of motion of the ankle, knee, and hip. Kinetic parameters included sagittal plane ankle power and ankle plantarflexion moment. Results: There was significant improvement in temporospatial parameters, including step length (P=.014) and walking velocity, which increased from 0.9 to 1 m/s (P=.01). Kinematic results showed sagittal plane range of motion of the ankle increased significantly from a mean of 15.8 degrees preoperatively to 20.6 degrees (P=.00005) postoperatively with the increase occurring primarily in dorsiflexion. Kinetic results showed ankle peak power increased from a mean of 0.7 Nm/kg to 1.1 Nm/kg (P=.004). Conclusions: A prospective study of gait in patients undergoing total ankle arthroplasty using a 2-component Salto Talaris device with a fixed polyethylene bearing showed, at midterm follow-up, significant improvements in multiple parameters of gait when compared to the patients' own preoperative function.
引用
收藏
页码:1472 / 1478
页数:7
相关论文