Image interpolation in 4D CT using a BSpline deformable registration model

被引:81
作者
Schreibmann, E
Chen, GTY
Xing, L
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 05期
关键词
four-dimensional computed tomography; deformable registration; image-guided radiotherapy; delineation; respiratory motion;
D O I
10.1016/j.ijrobp.2005.11.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a method for deriving the phase-binned four-dimensional computed tomography (4D CT) image sets through interpolation of the images acquired at some known phases. Methods and Materials: Four-dimensional computed tomography data sets for 3 patients were acquired. For each patient, the correlation between inhale and exhale phases was studied and quantified using a BSpline deformable model. Images at an arbitrary phase were deduced by an interpolation of the deformation coefficients. The accuracy of the proposed scheme was assessed by comparing marker trajectories and by checkerboard/difference display of the interpolated and acquired images. Results: The images at intermediate phases could be derived by an interpolation of the deformation field. An analysis of marker movements indicated that 3 mm accuracy is achievable by the interpolation. The subtraction of image analysis indicated a similar level of success. The proposed technique was useful also for automatically mapping the organ contours in a known phase to other phases, and for designing patient-specific margins in the presence of respiratory motion. Finally, the technique led to a 90% reduction in the acquired data, because in the BSpline model, a lattice of only a few thousand values is sufficient to describe a CT data set of 25 million pixels. Conclusions: Organ deformation can be well modeled by using a BSpline model. The proposed technique may offer useful means for radiation dose reduction, binning artifacts removal, and disk storage improvement in 4D imaging. (c) 2006 Elsevier Inc.
引用
收藏
页码:1537 / 1550
页数:14
相关论文
共 46 条
  • [1] Evaluation of the influence of breathing on the movement and modeling of lung tumors
    Allen, AM
    Siracuse, KM
    Hayman, JA
    Balter, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04): : 1251 - 1257
  • [2] Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
    Balter, JM
    TenHaken, RK
    Lawrence, TS
    Lam, KL
    Robertson, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01): : 167 - 174
  • [3] Berlinger K, 2004, LECT NOTES COMPUT SC, V3217, P925
  • [4] Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging
    Bharatha, A
    Hirose, M
    Hata, N
    Warfield, SK
    Ferrant, M
    Zou, KH
    Suarez-Santana, E
    Ruiz-Alzola, J
    D'Amico, A
    Cormack, RA
    Kikinis, R
    Jolesz, FA
    Tempany, CMC
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2551 - 2560
  • [5] Inclusion of organ deformation in dose calculations
    Brock, KK
    McShan, DL
    Ten Haken, RK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2003, 30 (03) : 290 - 295
  • [6] The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator
    Chui, CS
    Yorke, E
    Hong, L
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1736 - 1746
  • [7] Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines
    Coselmon, MM
    Balter, JM
    McShan, DL
    Kessler, ML
    [J]. MEDICAL PHYSICS, 2004, 31 (11) : 2942 - 2948
  • [8] A comparative study of warping and rigid body registration for the prostate and pelvic MR volumes
    Fei, BW
    Kemper, C
    Wilson, DL
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (04) : 267 - 281
  • [9] Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning
    Ford, EC
    Mageras, GS
    Yorke, E
    Ling, CC
    [J]. MEDICAL PHYSICS, 2003, 30 (01) : 88 - 97
  • [10] Quantifying the effect of intrafraction motion during breast IMRT planning and dose delivery
    George, R
    Keall, PJ
    Kini, VR
    Vedam, SS
    Siebers, JV
    Wu, Q
    Lauterbach, MH
    Arthur, DW
    Mohan, R
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 552 - 562