Quantitative assessment of late lumen loss after biodegradable polymer and permanent polymer sirolimus-eluting stents implantation

被引:2
作者
Kan Jing [1 ,2 ]
Chen Feng [2 ]
Liu Li-ya [2 ]
Xu Hai-mei [1 ]
Lin Ling [1 ]
Liu Yan [1 ]
Zhao Ying-ying [1 ]
Cheng Jiu-pei [3 ]
Chen Shao-liang [1 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Cardiol, Nanjing 210006, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Sch Publ Hlth, Nanjing 210006, Jiangsu, Peoples R China
[3] Xuancheng Municipal Peoples Hosp, Dept Cardiol, Xuancheng 420005, Anhui, Peoples R China
关键词
coronary artery disease; percutaneous coronary intervention; drug-eluting stent; late lumen loss; CORONARY-ARTERY; INTRAVASCULAR ULTRASOUND; E-SIRIUS; OUTCOMES; TRIAL; RESTENOSIS; THROMBOSIS; STENOSIS; LESIONS;
D O I
10.3760/cma.j.issn.0366-6999.20123385
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Sirolimus-eluting stents (SES) are reported to be associated with reduced late lumen loss (LLL), resulting in less frequent restenosis when compared to bare-metal stent. The current study aimed to assess the difference in LLL between SES with biodegradable and with permanent polymer. Methods From March 2010 to June 2011, 300 consecutive patients having only biodegradable polymers or permanent polymer SES for all diseased vessels were included. Serial quantitative coronary analysis was performed on both the "in-stent" and "segment" area, including the stented segment, as well as both five mm margins proximal and distal to the stent. The primary endpoint was the LLL defined as the minimal lumen diameter (MLD) post-stenting minus the MLD at nine-month after the indexed procedure. Results LLL was comparable between the two stents. Importantly, LLL for the distal segment (median 0.05 mm, interquartile 0 to 0.09 mm) was less severe compared with in-stent (median 0.13 mm, interquartile 0.08 to 0.18 mm) and proximal segment LLL (median 0.12 mm, interquartile 0.06 to 0.14 mm, all P<0.001). In general, the LLL was associated with the post-procedure MLD (b=0.28, P=0.002), hyperlipidemia (b=0.14, P=0.021), and calcified lesions (b=0.58, P=0.001). The R-2 and R-adj of the multiple regression model were 0.651 and 0.625, respectively. Conclusions SES with either biodegradable or permanent polymer had lower value of LLL. The small amount of LLL at the distal segment possibly contributed to the less distal edge stenosis.
引用
收藏
页码:1081 / 1085
页数:5
相关论文
共 24 条
[1]   An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study [J].
Barlis, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. ;
Dimopoulos, Konstantinos ;
van der Giessen, Willem J. ;
van Geuns, Robert-Jan M. ;
Ferrante, Giuseppe ;
Wandel, Simon ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Eerdmans, Pedro ;
Jueni, Peter ;
di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2010, 31 (02) :165-176
[2]   Distribution of angiographic measures of restenosis after drug-eluting stent implantation [J].
Byrne, R. A. ;
Eberle, S. ;
Kastrati, A. ;
Dibra, A. ;
Ndrepepa, G. ;
Iijima, R. ;
Mehilli, J. ;
Schoemig, A. .
HEART, 2009, 95 (19) :1572-1578
[3]   Angioscopy study from a large patient population comparing sirolimus-eluting stent with biodegradable versus durable polymer [J].
Chen, Shao-Liang ;
Xu, Tian ;
Zhang, Jun-Jie ;
Ye, Fei ;
Hu, Zuo-Ying ;
Tian, Nai-Liang ;
Zhang, Yao-Jun ;
Kotani, Junichi ;
Zhang, Jun-Xia .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (03) :420-428
[4]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[5]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[6]   Long-term clinical, angiographic, and intravascular ultrasound outcomes of biodegradable polymer-coated sirolimus-eluting stents [J].
Han, Yaling ;
Jing, Quanmin ;
Chen, Xuezhi ;
Wang, Shouli ;
Ma, Yingyan ;
Liu, Haiwei ;
Luan, Bo ;
Wang, Geng ;
Li, Yi ;
Wang, Zulu ;
Wang, Dongmei ;
Xu, Bo ;
Gao, Runlin .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (02) :177-183
[7]   Safety and Efficacy of Biodegradable Polymer-Coated Sirolimus-Eluting Stents in "Real-World" Practice 18-Month Clinical and 9-Month Angiographic Outcomes [J].
Han, Yaling ;
Jing, Quanmin ;
Xu, Bo ;
Yang, Lixia ;
Liu, Huiliang ;
Shang, Xiaoming ;
Jiang, Tieming ;
Li, Zhanquan ;
Zhang, Hua ;
Li, Hui ;
Qiu, Jian ;
Liu, Yingfeng ;
Li, Yi ;
Chen, Xuezhi ;
Gao, Runlin .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) :303-309
[8]   Vascular response to Sirolimus-Eluting Stents delivered with a NonAggressive implantation technique: Comparison of intravascular ultrasound results from the multicenter, Randomized E-SIRIUS, and SIRIUS trials [J].
Hoffmann, R ;
Guagliumi, G ;
Musumeci, G ;
Reimers, B ;
Petronio, AS ;
Disco, C ;
Amoroso, G ;
Moses, JW ;
Fitzgerald, PJ ;
Schofer, J ;
Leon, MB ;
Breithardt, G .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) :499-506
[9]  
Li Y, 2011, CHINESE MED J-PEKING, V124, P817, DOI 10.3760/cma.j.issn.0366-6999.2011.06.004
[10]   Long-term effects of biodegradable versus durable polymer-coated sirolimus-eluting stents on coronary arterial wall morphology assessed by virtual histology intravascular ultrasound [J].
Liu Hui-liang ;
Jin Zhi-geng ;
Luo Jian-ping ;
Ma Dong-xing ;
Yang Sheng-li ;
Liu Ying ;
Han Wei ;
Jing Li-min ;
Meng Rong-ying ;
Zhang Jiao .
CHINESE MEDICAL JOURNAL, 2011, 124 (06) :836-844