摘要
Modification of physical properties of polymer gels due to radiation induced polymerization and cross-linking processes in polymer structures is related to the absorbed doses. It is possible to obtain 3D-dose distributions in the irradiated objects however dose calibration should be performed prior to dose evaluation. Dose calibration of low dose gamma irradiated normoxic PAG gels is discussed in the present paper. Optical properties of home made polymer gels irradiated in medical Co-60 unit have been investigated and absorption coefficients were evaluated. These coefficients have been used for the construction of dose calibration curves. It was found that the irradiated polymer gels are sensitive enough to record low doses. Since proposed calibration method is although real time sensitive, the limitations of the method are discussed.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 50 条
  • [1] Application of normoxic polymer gels in 3D-dosimetry for radiosurgery
    Scheib, Stefan
    Crescenti, Remo
    Vogelsanger, Walter
    Schenkel, Yvonne
    Gianolini, Stefano
    Lazaridis, Emmanuil
    Mack, Andreas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (03): : 180 - 187
  • [2] Application of NMR microscopy to polymer gels and polymer blends
    Kuroki, S
    Koizumi, S
    Yamane, Y
    Ando, I
    KOBUNSHI RONBUNSHU, 2005, 62 (10) : 458 - 466
  • [3] Application of polymer dose gels for millimeter scale target/tumor pre-treatment immitation using gamma knife facility
    Jaselske, Evelina
    Adliene, Diana
    Rudzianskas, Viktoras
    Korobeinikova, Erika
    Radziunas, Andrius
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 470 (470): : 56 - 60
  • [4] Assessment and characterization of the total geometric uncertainty in Gamma Knife radiosurgery using polymer gels
    Moutsatsos, A.
    Karaiskos, P.
    Petrokokkinos, L.
    Sakelliou, L.
    Pantelis, E.
    Georgiou, E.
    Torrens, M.
    Seimenis, I.
    MEDICAL PHYSICS, 2013, 40 (03)
  • [5] A New Fluorometric Dosimetry for Low-medium Gamma Radiation Doses
    Ece Ergun
    Journal of Fluorescence, 2021, 31 : 941 - 950
  • [6] A New Fluorometric Dosimetry for Low-medium Gamma Radiation Doses
    Ergun, Ece
    JOURNAL OF FLUORESCENCE, 2021, 31 (04) : 941 - 950
  • [7] Application of Dose Gels in HDR Brachytherapy
    Adliene, D.
    Jakstas, K.
    Vaiciunaite, N.
    Laurikaitiene, J.
    Cerapaite-Trusinskiene, R.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 724 - 727
  • [8] Friction of polymer gels and the potential application as artificial cartilage
    Gong, JP
    Iwasaki, Y
    Kagata, G
    Osada, Y
    SMART STRUCTURES AND MATERIALS 1999: ELECTROACTIVE POLYMER ACTUATORS AND DEVICES, 1999, 3669 : 218 - 225
  • [9] Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air
    Khailov, A. M.
    Ivannikov, A. I.
    Skvortsov, V. G.
    Stepanenko, V. F.
    Orlenko, S. P.
    Flood, A. B.
    Williams, B. B.
    Swartz, H. M.
    RADIATION MEASUREMENTS, 2015, 82 : 1 - 7
  • [10] Characterization of aqueous rose bengal dye solution for the measurement of low doses of gamma radiation
    Hasan Mahmood Khan
    Ashfaq A. Khan
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 284 : 37 - 42