The effectiveness of robotic hip and knee arthroplasty on patient-reported outcomes: A systematic review and meta-analysis

被引:64
作者
Karunaratne, Sascha [1 ]
Duan, Michael [2 ]
Pappas, Evangelos [3 ]
Fritsch, Brett [4 ]
Boyle, Richard [4 ]
Gupta, Sanjeev [4 ]
Stalley, Paul [4 ]
Horsley, Mark [4 ]
Steffens, Daniel [1 ,2 ]
机构
[1] RPAH, Surg Outcomes Res Ctr SOuRCe, POB M157, Sydney, NSW 2050, Australia
[2] Univ Sydney, Fac Med & Hlth, Sydney, NSW, Australia
[3] Univ Sydney, Fac Hlth Sci, Sydney, NSW, Australia
[4] RPAH, Dept Orthopaed Surg, Sydney, NSW, Australia
关键词
Robotic surgery; Hip; Knee; Arthroplasty; Patient-reported outcomes; MANUAL IMPLANTATION; REPLACEMENT; QUALITY; STEM;
D O I
10.1007/s00264-018-4140-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe purpose of the study is to determine the effectiveness of semi-active and active robotic hip and knee arthroplasty on post-operative patient-reported outcomes of function, pain, quality of life and satisfaction with surgery.MethodsPubMed, Medline, Embase and CENTRAL were searched. Included were comparative studies investigating the effectiveness of semi-active or active robotic hip or knee arthroplasty compared to any other surgical intervention on function, pain, quality of life and satisfaction with surgery. Risk of bias and the strength of the evidence were assessed using the Downs and Black tool and the GRADE system, respectively. Relative risks, mean differences and 95% CI were calculated using random-effects models.ResultsFourteen studies involving 1342 patients were included. All studies compared robotic to conventional surgery, with active robotic surgery evaluated in total hip or knee arthroplasty and semi-active robotic surgery in total hip or unicompartmental knee arthroplasty. Most studies presented some risk of bias, and the strength of evidence was rated as low to very low quality. Random-effects meta-analyses showed that post-operative functional outcomes were comparable between active robotic and conventional total hip and knee arthroplasty at the short-, medium- and long-term follow-up. No significant difference in pain, quality of life and satisfaction with surgery were reported in individual studies.ConclusionsThis systematic and meta-analyses indicates that functional outcomes for patients undergoing active robotic total hip and knee arthroplasty were comparable to conventional surgery. Whether semi-active or active robotic hip or knee arthroplasty is effective in improving post-operative pain, quality of life and satisfaction with surgery is unclear.PROSPERO Registration Number: CRD42017059932.
引用
收藏
页码:1283 / 1295
页数:13
相关论文
共 43 条
[1]  
[Anonymous], 2016, AJRRS PAT REP OUTC M
[2]  
[Anonymous], IMPACTS ADV MEDICAL
[3]  
[Anonymous], COMPUTER ROBOTIC ASS
[4]  
[Anonymous], INT J MED ROBOT
[5]  
[Anonymous], PAT REP OUTC MEAS PR
[6]  
[Anonymous], 2017, ICHOM HIP KNEE OST D
[7]  
[Anonymous], PAPER PRESENTED AMER
[8]   Systems for grading the quality of evidence and the strength of recommendations -: I:: Critical appraisal of existing approaches The GRADE Working Group -: art. no. 38 [J].
Atkins, D ;
Eccles, M ;
Flottorp, S ;
Guyatt, GH ;
Henry, D ;
Hill, S ;
Liberati, A ;
O'Connell, D ;
Oxman, AD ;
Phillips, B ;
Schünemann, H ;
Edejer, TTT ;
Vist, GE ;
Williams, JW .
BMC HEALTH SERVICES RESEARCH, 2004, 4 (1)
[9]  
Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), 2017, HIP KNEE SHOULD ARTH
[10]  
Bargar WL, 1998, CLIN ORTHOP RELAT R, P82