Evaluation of intracranial aneurysms with high-resolution MR angiography using single-artery highlighting technique: correlation with digital subtraction angiography

被引:0
作者
Li, Hui [1 ]
Yan, Lei [1 ]
Li, Ming-Hua [1 ]
Li, Yong-Dong [1 ]
Tan, Hua-Qiao [1 ]
Gu, Bin-Xian [1 ]
Wang, Wu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Inst Diagnost & Intervent Radiol, Shanghai 200030, Peoples R China
来源
RADIOLOGIA MEDICA | 2013年 / 118卷 / 08期
关键词
Magnetic resonance angiography; Intracranial aneurysm; Digital subtraction angiography; Rotational digital subtraction angiography; Volume rendering; MAGNETIC-RESONANCE ANGIOGRAPHY; MAXIMUM-INTENSITY-PROJECTION; CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; CONTRAST; DSA;
D O I
10.1007/s11547-012-0871-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. The authors investigated the effectiveness of high-resolution magnetic resonance angiography (MRA) using a single-artery highlighting technique for the accurate diagnosis of intracranial aneurysms at 3.0 T in a large cohort of patients with suspected intracranial aneurysms against the current gold standard, i.e. cerebral angiography. Methods. A total of 307 patients with suspected aneurysms were referred for three-dimensional time-of-flight MRA (3D-TOF-MRA) prior to digital subtraction angiography (DSA). We summarised patient-based, aneurysm-based and vessel-based diagnostic performance parameters, namely, accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detecting intracranial aneurysms with 3D-TOF-MRA. Interobserver agreement was calculated with the kappa (kappa) statistic. Results. Patient-based accuracy was 98.1%, sensitivity 99.5%, specificity 95.3%, PPV 97.6% and NPV 99% according to observer A; and 97.7%, 99.5%, 94.3%, 97.1% and 99%, respectively, according to observer B. Aneurysm-based accuracy was 98.3%, sensitivity 99.6%, specificity 95.2%, PPV 98.1% and NPV 99% according to observer A, and 98.0%, 99.6%, 94.3%, 97.7% and 99%, respectively, according to observer B. Vessel-based accuracy was 99.0%, sensitivity 99.6%, specificity 98.7%, PPV 97.8%, and NPV 99.7% according to observer A, and 98.9%, 99.6%, 98.5%, 97.3%, and 99.7%, respectively, according to observer B. Interobserver reading differences were not significant. The interobserver agreement was good, with a kappa (kappa) value of 0.931 for patient-based evaluation, 0.934 for aneurysm-based evaluation and 0.953 for vessel-based evaluation. Conclusions. Our results demonstrate the effectiveness of high-resolution MRA using a single-artery-highlighting technique for accurate diagnosis of intracranial aneurysms in a large cohort of patients with suspected aneurysms.
引用
收藏
页码:1379 / 1387
页数:9
相关论文
共 21 条
[1]   Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries [J].
Al-Kwifi, O ;
Emery, DJ ;
Wilman, AH .
MAGNETIC RESONANCE IMAGING, 2002, 20 (02) :181-187
[2]   Intracranial aneurysms: Detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study [J].
Atlas, SW ;
Sheppard, L ;
Goldberg, HI ;
Hurst, RW ;
Listerud, J ;
Flamm, E .
RADIOLOGY, 1997, 203 (03) :807-814
[3]   Medical progress: Cerebral aneurysms [J].
Brisman, Jonathan L. ;
Song, Joon K. ;
Newell, David W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (09) :928-939
[4]  
Grandin CB, 1998, AM J NEURORADIOL, V19, P245
[5]   Intracranial aneurysms: Diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images [J].
Korogi, Y ;
Takahashi, M ;
Mabuchi, N ;
Nakagawa, T ;
Fujiwara, S ;
Horikawa, Y ;
Miki, H ;
OUchi, T ;
Shiga, H ;
Shiokawa, Y ;
Watabe, T ;
Furuse, M .
RADIOLOGY, 1996, 199 (01) :199-207
[6]   INTRACRANIAL ANEURYSMS - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
KOROGI, Y ;
TAKAHASHI, M ;
MABUCHI, N ;
MIKI, H ;
FUJIWARA, S ;
HORIKAWA, Y ;
NAKAGAWA, T ;
OUCHI, T ;
WATABE, T ;
SHIGA, H ;
FURUSE, M .
RADIOLOGY, 1994, 193 (01) :181-186
[7]   Contrast-free MRA at 3.0 T for the detection of intracranial aneurysms [J].
Li, M. -H. ;
Li, Y. -D. ;
Tan, H. -Q. ;
Gu, B. -X. ;
Chen, Y. -C. ;
Wang, W. ;
Chen, S. -W. ;
Hu, D. -J. .
NEUROLOGY, 2011, 77 (07) :667-676
[8]   Large-Cohort Comparison Between Three-Dimensional Time-of-Flight Magnetic Resonance and Rotational Digital Subtraction Angiographies in Intracranial Aneurysm Detection [J].
Li, Ming-Hua ;
Cheng, Ying-Sheng ;
Li, Yong-Dong ;
Fang, Chun ;
Chen, Shi-Wen ;
Wang, Wu ;
Hu, Ding-Jun ;
Xu, Hao-Wen .
STROKE, 2009, 40 (09) :3127-3129
[9]   Evaluation of 64-Section CT Angiography for Detection and Treatment Planning of Intracranial Aneurysms by Using DSA and Surgical Findings [J].
Li, Qi ;
Lv, Fajin ;
Li, Yongmei ;
Luo, Tianyou ;
Li, Kewei ;
Xie, Peng .
RADIOLOGY, 2009, 252 (03) :808-815
[10]   Investigation of cerebrovascular disease with MR angiography: comparison of volume rendering and maximum intensity projection algorithms - initial assessment [J].
Mallouhi, A ;
Chemelli, A ;
Judmaier, W ;
Giacomuzzi, S ;
Jaschke, WR ;
Waldenberger, P .
NEURORADIOLOGY, 2002, 44 (12) :961-967