Assessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer

被引:345
作者
Choi, Leena [1 ]
Ward, Suzanne Capen [2 ]
Schnelle, John F. [3 ,4 ]
Buchowski, Maciej S. [2 ]
机构
[1] Vanderbilt Univ, Sch Med, Dept Biostat, Med Ctr N, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Sch Med, Energy Balance Lab, Div Gastroenterol Hepatol & Nutr, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Sch Med, Div Gen Internal Med & Publ Hlth, Ctr Qual Aging, Nashville, TN 37232 USA
[4] VA Med Ctr, Geriatr Res Educ & Clin Ctr, Nashville, TN USA
基金
美国国家卫生研究院;
关键词
NONWEAR CATEGORIZATION; PHYSICAL ACTIVITY ASSESSMENT; ACCELEROMETRY; SEDENTARY BEHAVIOR; PHYSICAL-ACTIVITY; UNITED-STATES; OLDER-ADULTS; WEARABLE MONITORS; SEDENTARY TIME; MORTALITY; CALIBRATION; OUTCOMES; FIELD;
D O I
10.1249/MSS.0b013e318258cb36
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
CHOI, L., S. C. WARD, J. F. SCHNELLE, and M. S. BUCHOWSKI. Assessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer. Med. Sci. Sports Exerc., Vol. 44, No. 10, pp. 2009-2016, 2012. Purpose: The objective of this study is to assess the performance of existing wear/nonwear time classification algorithms for accelerometry data collected in the free-living environment using a wrist-worn triaxial accelerometer and a waist-worn uniaxial accelerometer in older adults. Methods: Twenty-nine adults age 76 to 96 yr wore wrist accelerometers for approximately 24 h per day and waist accelerometers during waking for approximately 7 d of free living. Wear and nonwear times were classified by existing algorithms (Alg([ActiLife]), Alg([Troiano]), and Alg([Choi])) and compared with wear and nonwear times identified by data plots and diary records. With the use of bias and probability of correct classification, the performance of the algorithms, two time windows (60 and 90 min), and vector magnitude (VM) versus vertical axis (V) counts from a triaxial accelerometer were compared. Results: Automated algorithms (Alg([Choi]) and Alg([Troiano])) classified wear/nonwear time intervals more accurately from VM than V counts. The use of the 90-min time window improved wear/nonwear classification accuracy when compared with the 60-min window. The Alg([Choi]) and Alg([Troiano]) performed better than the manufacturer-provided algorithm (Alg([ActiLife])), and the Alg([Choi]) performed better than the Alg([Troiano]) for wear/nonwear time classification using the data collected by both accelerometers. Conclusions: Triaxial wrist-worn accelerometer can be used for an accurate wear/nonwear time classification in free-living older adults. The use of the 90-min window and the VM counts improves the performance of commonly used algorithms for wear/nonwear classification for both uniaxial and triaxial accelerometers.
引用
收藏
页码:2009 / 2016
页数:8
相关论文
共 21 条
[1]   Calibration and Validation of Wearable Monitors [J].
Bassett, David R., Jr. ;
Rowlands, Alex ;
Trost, Stewart G. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 :S32-S38
[2]   Patterns of physical activity in free-living adults in the Southern United States [J].
Buchowski, MS ;
Acra, S ;
Majchrzak, KM ;
Sun, M ;
Chen, KY .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2004, 58 (05) :828-837
[3]  
Choi L., 2011, PHYS ACTIVITY PROCES
[4]   Validation of Accelerometer Wear and Nonwear Time Classification Algorithm [J].
Choi, Leena ;
Liu, Zhouwen ;
Matthews, Charles E. ;
Buchowski, Maciej S. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (02) :357-364
[5]   Assessment of Physical Activity Using Wearable Monitors: Recommendations for Monitor Calibration and Use in the Field [J].
Freedson, Patty ;
Bowles, Heather R. ;
Troiano, Richard ;
Haskell, William .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 :S1-S4
[6]   Physical activity and inactivity in an adult population assessed by accelerometry [J].
Hagstromer, Maria ;
Oja, Pekka ;
Sjostrom, Michael .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (09) :1502-1508
[7]   Measurement of Adults' Sedentary Time in Population-Based Studies [J].
Healy, Genevieve N. ;
Clark, Bronwyn K. ;
Winkler, Elisabeth A. H. ;
Gardiner, Paul A. ;
Brown, Wendy J. ;
Matthews, Charles E. .
AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2011, 41 (02) :216-227
[8]   Measuring fatigue in patients with Parkinson's disease - the Fatigue Severity Scale [J].
Herlofson, K ;
Larsen, JP .
EUROPEAN JOURNAL OF NEUROLOGY, 2002, 9 (06) :595-600
[9]   Daily activity energy expenditure and mortality among older adults [J].
Manini, Todd M. ;
Everhart, James E. ;
Patel, Kushang V. ;
Schoeller, Dale A. ;
Colbert, Lisa H. ;
Visser, Marjolein ;
Tylavsky, Frances ;
Bauer, Douglas C. ;
Goodpaster, Bret H. ;
Harris, Tamara B. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (02) :171-179
[10]   Amount of time spent in sedentary behaviors in the united states, 2003-2004 [J].
Matthews, Charles E. ;
Chen, Kong Y. ;
Freedson, Patty S. ;
Buchowski, Maciej S. ;
Beech, Bettina M. ;
Pate, Russell R. ;
Troiano, Richard P. .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 167 (07) :875-881