Compact 151W green laser with U-type resonator for prostate surgery

被引:16
作者
Bazyar, Hossein [1 ]
Aghaie, Mohammad [1 ]
Daemi, Mohammad Hossein [1 ]
Bagherzadeh, Seyed Morteza [1 ]
机构
[1] Iranian Natl Ctr Laser Sci & Technol INLC, Tehran, Iran
关键词
Nd:YAG laser; Intracavity-frequency-doubled; U-type resonator; ND-YAG LASER; BEAM GENERATION; KTP LASER; ROD LASER; VAPORIZATION;
D O I
10.1016/j.optlastec.2012.09.016
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We analyzed, designed and fabricated a U-type resonator for intra-cavity frequency doubling of a diode-side-pumped Q-switched Nd:YAG rod laser with high power and high stability for surgery of prostatic tissue. The resonator stability conditions were analyzed graphically in the various configurations for a U-type resonator. We obtained green light at 532 nm using a single KTP crystal, with average output power of 151 W at 10 kHz repetition rate, and with 113 ns pulse duration at 810W input pump power. We achieved 1064-532 nm conversion efficiency of 75.8%, and pump-to-green optical-optical efficiency of 18.6%. The green power fluctuation was +/- 1.0% and pointing stability was better than 4 wad. The green laser output was coupled to a side-firing medical fiber to transfer the laser beam to the prostatic tissue. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:237 / 241
页数:5
相关论文
共 18 条
[1]   High-power KTP laser prostatectomy: the new challenge to transurethral resection of the prostate [J].
Barber, NJ ;
Muir, GH .
CURRENT OPINION IN UROLOGY, 2004, 14 (01) :21-25
[2]   High average power Q-switched green beam generation by intracavity frequency doubling of diode-side-pumped Nd:YAG/HGTR-KTP laser [J].
Chen, Haowei ;
Chen, Xiuyan ;
Li, Xiu ;
Hou, Yao ;
Wang, Siyuan ;
Ren, Zhaoyu ;
Bai, Jintao .
OPTICS AND LASER TECHNOLOGY, 2009, 41 (01) :1-4
[3]   Technique and short-term outcome of green light laser (KTP, 80 W) vaporisatlion of the prostate [J].
Heinrich, Elmar ;
Schiefelbein, Frank ;
Schoen, Georg .
EUROPEAN UROLOGY, 2007, 52 (06) :1632-1637
[4]   Laser Fibre Deterioration and Loss of Power Output During Photo-Selective 80-W Potassium-Titanyl-Phosphate Laser Vaporisation of the Prostate [J].
Hermanns, Thomas ;
Sulser, Tullio ;
Fatzer, Markus ;
Baumgartner, Martin K. ;
Rey, Julien M. ;
Sigrist, Markus W. ;
Seifert, Hans-Helge .
EUROPEAN UROLOGY, 2009, 55 (03) :679-686
[5]  
Koechner W., 1996, SOLID STATE LASER EN
[6]   Stabilization of a high-power diode-side-pumped intracavity-frequency-doubled CW Nd:YAG laser by compensating for thermal lensing of a KTP crystal and Nd:YAG rods [J].
Kojima, T ;
Fujikawa, S ;
Yasui, K .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1999, 35 (03) :377-380
[7]   Highly efficient 68-W green-beam generation by use of an intracavity frequency-doubled diode side-pumped Q-switched Nd:YAG rod laser [J].
Konno, S ;
Fujikawa, S ;
Yasui, K .
APPLIED OPTICS, 1998, 37 (27) :6401-6404
[8]   Efficient high-power green beam generation by use of an intracavity frequency-doubled laser-diode-pumped Q-switched Nd:YAG laser [J].
Konno, S ;
Yasui, K .
APPLIED OPTICS, 1998, 37 (03) :551-554
[9]   High-brightness 138-W green laser based on an intracavity-frequency-doubled diode-side-pumped Q-switched Nd:YAG laser [J].
Konno, S ;
Kojima, T ;
Fujikawa, S ;
Yasui, K .
OPTICS LETTERS, 2000, 25 (02) :105-107
[10]   High-average-power diode-array-pumped frequency-doubled YAG laser [J].
LeGarrec, BJ ;
Raze, GJ ;
Thro, PY ;
Gilbert, M .
OPTICS LETTERS, 1996, 21 (24) :1990-1992