Accurate and reproducible ion mobility measurements for chemical standard evaluation

被引:39
作者
Crawford, C. L. [1 ]
Hauck, B. C. [1 ]
Tufariello, J. A. [1 ]
Harden, C. S. [2 ]
McHugh, V. [2 ]
Siems, W. F. [1 ]
Hill, H. H., Jr. [1 ]
机构
[1] Washington State Univ, Dept Chem, Pullman, WA 99164 USA
[2] USA, Edgewood Chem & Biol Ctr, Aberdeen Proving Ground, MD 21010 USA
关键词
IMS; MS; Chemical standards; DtBP; TNT; Error estimation; ATMOSPHERIC-PRESSURE; ORGANOPHOSPHORUS COMPOUNDS; ELECTROSPRAY-IONIZATION; DEGRADATION-PRODUCTS; SPECTROMETRY; MASS; TEMPERATURE; RESOLUTION; DEPENDENCE;
D O I
10.1016/j.talanta.2012.09.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Chemical standards are used to calibrate ion mobility spectrometers (IMS) for accurate and precise identification of target compounds. Research over the past 30 years has identified several positive and negative mode compounds that have been used as IMS standards. However, the IMS research community has not come to a consensus on any chemical compound(s) for use as a reference standard. Also, the reported K-0 values for the same compound analyzed on several IMS systems can be inconsistent. In many cases, mobility has not been correlated with a mass identification of an ion. The primary goal of this work was to provide mass-identified mobility (K-0) values for standards. The results of this work were mass-identified K-0 values for positive and negative mode IMS chemical standards. The negative mode results of this study showed that TNT is a viable negative mode reference standard. New temperature-dependent K-0 values were found by characterizing drift gas temperature and water content; several examples were found of temperature-dependent changes for the ion species of several standards. The overall recommendation of this study is that proposed IMS standards should have temperature-dependent K-0 values quoted in the literature instead of using a single K-0 value for a compound. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:161 / 170
页数:10
相关论文
共 46 条
[1]  
AnonGE Sensing, 2005, MOIST IM SER 1 SPEC
[2]   A self-calibrating programable mobility spectrometer for atmospheric ion measurements [J].
Aplin, KL ;
Harrison, RG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08) :3467-3469
[3]   Separation and identification of some chemical warfare degradation products using electrospray high resolution ion mobility spectrometry with mass selected detection [J].
Asbury, GR ;
Wu, C ;
Siems, WF ;
Hill, HH .
ANALYTICA CHIMICA ACTA, 2000, 404 (02) :273-283
[4]   Electrospray ionization nigh-resolution ion mobility spectrometry for the detection of organic compounds, 1. Amino acids [J].
Beegle, LW ;
Kanik, I ;
Matz, L ;
Hill, HH .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3028-3034
[5]  
Bocos-Bintintan V., 2002, CHEMIA, V47, P149
[6]   Analysis of Black Powder by Ion Mobility-Time-of-Flight Mass Spectrometry [J].
Crawford, Christina L. ;
Boudries, Hacene ;
Reda, Ralph J. ;
Roscioli, Kristyn M. ;
Kaplan, Kimberly A. ;
Siems, William F. ;
Hill, Herbert H., Jr. .
ANALYTICAL CHEMISTRY, 2010, 82 (01) :387-393
[7]   The role of oxygen in the formation of TNT product ions in ion mobility spectrometry [J].
Daum, KA ;
Atkinson, DA ;
Ewing, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 214 (02) :257-267
[8]  
Davies D.K., 1994, AUTOMATIC COMPENSATI
[9]  
Eiceman G.A., 1998, Int. J. Ion Mobil. Spec, V1, P28
[10]  
EICEMAN GA, 1989, ANAL INSTRUM, V18, P227