Performance Evaluation of Hybrid Radiant Cooling System Integrated with Decentralized Ventilation System in Hot and Humid Climates

被引:11
作者
Cui, Shixin [1 ]
Kim, Moon Keun [2 ]
Papadikis, Konstantinos [1 ]
机构
[1] Xian Jiaotong Liverpool Univ, Dept Civil Engn, Suzhou 215123, Peoples R China
[2] Xian Jiaotong Liverpool Univ, Dept Architecture, Suzhou 215123, Peoples R China
来源
10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017 | 2017年 / 205卷
关键词
Energy performance; Hybrid radiant cooling; Decentralized ventilation; Airbox convector; AIRBOX CONVECTOR; PANEL; DEHUMIDIFICATION; ENVIRONMENT; BUILDINGS; CAPACITY; IMPACT;
D O I
10.1016/j.proeng.2017.10.367
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-cooling systems become a must especially in office buildings to keep the indoor environment comfort. In this study, a normal cooling systems become a must especially in office buildings to keep the indoor environment comfort. In this study, a normal office room is designed to evaluate a novel cooling system based on a hot and humid climate. This novel cooling system is considered to serve such climate, which integrates radiant cooling panel, decentralized ventilation, and an Airbox convector. The Airbox convector is designed to deal with condensation risk and provide additional cooling output. In order to evaluate this novel system, it is compared with conventional all-air system and normal radiant system with decentralized ventilation regarding to the system capacity, energy consumption and thermal comfort. Results show that this novel system is adaptable to such climates and capable to reduce the condensation risk and overall cooling energy consumption. (c) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1245 / 1252
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 2013, ASHRAE HDB FUND
[2]  
Baldini L., 2009, ADV BUILDING VENTILA
[3]   Decentralized cooling and dehumidification with a 3 stage LowEx heat exchanger for free reheating [J].
Baldini, Luca ;
Kim, Moon Keun ;
Leibundgut, Hansjuerg .
ENERGY AND BUILDINGS, 2014, 76 :270-277
[4]   Building energy-consumption status worldwide and the state-of-the-art technologies for zero-energy buildings during the past decade [J].
Cao, Xiaodong ;
Dai, Xilei ;
Liu, Junjie .
ENERGY AND BUILDINGS, 2016, 128 :198-213
[5]   Simplified cooling capacity estimation model for top insulated metal ceiling radiant cooling panels [J].
Jeong, JW ;
Mumma, SA .
APPLIED THERMAL ENGINEERING, 2004, 24 (14-15) :2055-2072
[6]   Impact of mixed convection on ceiling radiant cooling panel capacity [J].
Jeong, JW ;
Mumma, SA .
HVAC&R RESEARCH, 2003, 9 (03) :251-257
[7]   Performance evaluation of radiant cooling system integrated with air system under different operational strategies [J].
Khan, Yasin ;
Khare, Vaibhav Rai ;
Mathur, Jyotirmay ;
Bhandari, Mahabir .
ENERGY AND BUILDINGS, 2015, 97 :118-128
[8]  
Kim M.K., 2015, P 1 INT C SUST BUILD, P29
[9]   Energy analysis of a decentralized ventilation system compared with centralized ventilation systems in European climates: Based on review of analyses [J].
Kim, Moon Keun ;
Baldini, Luca .
ENERGY AND BUILDINGS, 2016, 111 :424-433
[10]   Advanced Airbox cooling and dehumidification system connected with a chilled ceiling panel in series adapted to hot and humid climates [J].
Kim, Moon Keun ;
Leibundgut, Hansjuerg .
ENERGY AND BUILDINGS, 2014, 85 :72-78