Structural use of fiber-reinforced self-compacting concrete with recycled aggregates: Case study of a foundation wall in Spain

被引:6
作者
Ortiz-Lozano, Jose A. [1 ,3 ]
Mena-Sebastia, Francisco [2 ]
Segura, Ignacio [2 ]
de la Fuente, Albert [2 ]
Aguado, Antonio [2 ]
机构
[1] Univ Autonoma Aguascalientes, Dept Construct & Struct, Aguascalientes, Mexico
[2] Univ Politecn Cataluna, Dept Civil & Environm Engn, UPC Tech, Barcelona, Spain
[3] Autonomous Univ Aguascalientes, Dept Civil Engn, Ciudad Univ,Av Univ 940,Module 108, Aguascalientes 20100, Mexico
关键词
Fiber-reinforced concrete; Recycled aggregates; Toughness; Self-compacting concrete; Full-scale test; MECHANICAL-PROPERTIES; WATER-ABSORPTION; COARSE; CONSTRUCTION; PERFORMANCE; ORIENTATION; PREDICTION; BARCELONA; BEHAVIOR; DESIGN;
D O I
10.1016/j.cscm.2022.e01334
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is focused on the use of mixed recycled-aggregates (RA), replacing 100% of the natural coarse aggregates, for producing steel fiber reinforced self-compacting concrete (FR-SCC-RA) oriented to the construction of foundation walls. To this end, an extensive experimental program dedicated to the mechanical characterization of FR-SCC-RA foundation walls from the material and structural level was carried out. The former was developed on both molded specimens and cores extracted from the in-situ constructed FR-SCC-RA walls in Barcelona, Spain. The results lead to confirm that the use of RA resulted satisfactorily from both the concrete manufacturing and the mechanical performance, since no affectations on the design mechanical variables (i.e., compressive and flexural tensile strengths) were detected. Likewise, the results derived from the full-scale test evidenced that the residual loads of the slabs tested were significantly higher than those calculated based on the test results of the prismatic core samples. The main outcome derived from the experimental research program is that FR-SCC-RA might be a suitable material for this structural typology and that the tested slabs presented a sufficient post-cracking residual capacity-due to the incorporation of structural fibers-for avoiding fragile failures. These con-clusions could be extended to other countries where similar restrictive regulations and standards are present, regarding the use of RA and FRC for structural applications.
引用
收藏
页数:16
相关论文
共 70 条
[1]   Strength behavior of reinforced concrete beam using re-cycle of PET wastes as synthetic fibers [J].
Adnan, Hamsa M. ;
Dawood, Abbas O. .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2020, 13
[2]   Construction of road sections using mixed recycled aggregates treated with cement in Malaga, Spain [J].
Agrela, Francisco ;
Barbudo, Auxi ;
Ramirez, Antonio ;
Ayuso, Jesus ;
Dolores Carvajal, Maria ;
Ramon Jimenez, Jose .
RESOURCES CONSERVATION AND RECYCLING, 2012, 58 :98-106
[3]   Mechanical properties and durability assessment of nylon fiber reinforced self-compacting concrete [J].
Ahmad, Jawad ;
Zaid, Osama ;
Aslam, Fahid ;
Martinez-Garcia, Rebeca ;
Elharthi, Yasir M. ;
El Ouni, Mohamed Hechmi ;
Tufail, Faisal ;
Sharaky, Ibrahim A. .
JOURNAL OF ENGINEERED FIBERS AND FABRICS, 2021, 16
[4]   Structural response of a fibre reinforced concrete pile-supported flat slab: full-scale test [J].
Aidarov, Stanislav ;
Mena, Francisco ;
de la Fuente, Albert .
ENGINEERING STRUCTURES, 2021, 239
[5]   Effect of low-modulus polypropylene fiber on physical and mechanical properties of self-compacting concrete [J].
Akhmetov, Daniyar ;
Akhazhanov, Sungat ;
Jetpisbayeva, Ainur ;
Pukharenko, Yuri ;
Root, Yelena ;
Utepov, Yelbek ;
Akhmetov, Akbulat .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 16
[6]   Mechanical and physical characterisation of steel fibre reinforced self-compacting concrete: Different aspect ratios and volume fractions of fibres [J].
Alrawashdeh, Anas ;
Eren, Ozgur .
RESULTS IN ENGINEERING, 2022, 13
[7]  
[Anonymous], 2007, PROC 4 INT STRUCT EN
[8]  
[Anonymous], 2020, 1239032020 UNEEN
[9]  
[Anonymous], 2005, THESIS
[10]  
[Anonymous], 2014, 12390132014 UNEEN