Tear Film Images and Breakup Analyzed Using Fluorescent Quenching

被引:40
作者
King-Smith, P. Ewen [1 ]
Ramamoorthy, Padmapriya [1 ]
Braun, Richard J. [2 ]
Nichols, Jason J. [3 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
[2] Univ Delaware, Dept Math Sci, Newark, DE 19716 USA
[3] Univ Houston, Coll Optometry, Houston, TX USA
基金
美国国家科学基金会;
关键词
breakup; fluorescence; quenching; evaporation; tangential flow; LIPID LAYER; REPEATABILITY; EVAPORATION; PRECORNEAL; CORNEAL; INSTABILITY; VALUES; TIME;
D O I
10.1167/iovs.13-12628
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Tear evaporation should increase fluorescein concentration, causing fluorescence dimming from self-quenching for high but not low fluorescein concentration. This prediction was tested and compared to the predicted effect of "tangential flow'' that fluorescence dimming should be similar for high and low concentrations. METHODS. A custom optical system was used for video recording of tear film fluorescence in 30 subjects. The subjects were asked to blink at the start of the recording and try to keep their eyes open for the rest of the 60-second recording. An initial recording was made after instillation of 1 mu L 0.1% fluorescein followed by further recordings at 5-minute intervals using 0.5% and 5% fluorescein. RESULTS. Decay of fluorescence was considerably greater for the high (5%) concentration condition than for the low (0.1%) concentration. This is shown by "ratio images'' (ratio of the intensity of a fluorescence image at a later time divided by that of an earlier image), fluorescence decay curves, fluorescence decay rates, and histograms of estimated tear thickness decrease. For example, for the high concentration condition, decay rates were higher than for the low concentration for all 30 subjects (P < 0.0001, binomial test). Additionally, breakup time was significantly reduced for the high compared to the low concentration condition. CONCLUSIONS. The greater fluorescence decay and more rapid breakup for the high concentration condition are the results expected if thinning and breakup are mainly due to evaporation, hence causing self-quenching. Fluorescence decay rate for the low concentration condition was not significantly greater than zero.
引用
收藏
页码:6003 / 6011
页数:9
相关论文
共 33 条
  • [1] Abelson MB, 2002, ADV EXP MED BIOL, V506, P1121
  • [2] Quantitative Analysis of Tear Film Fluorescence and Discomfort During Tear Film Instability and Thinning
    Begley, Carolyn
    Simpson, Trefford
    Liu, Haixia
    Salvo, Eliza
    Wu, Ziwei
    Bradley, Arthur
    Situ, Ping
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) : 2645 - 2653
  • [3] Tear breakup dynamics: A technique for quantifying tear film instability
    Begley, CG
    Himebaugh, N
    Renner, D
    Liu, HX
    Chalmers, R
    Simpson, T
    Varikooty, J
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (01) : 15 - 21
  • [4] SURFACE-TENSION GRADIENT MECHANISM FOR DRIVING PRECORNEAL TEAR FILM AFTER A BLINK
    BERGER, RE
    CORRSIN, S
    [J]. JOURNAL OF BIOMECHANICS, 1974, 7 (03) : 225 - &
  • [5] Grading of corneal and conjunctival staining in the context of other dry eye tests
    Bron, AJ
    Evans, VE
    Smith, JA
    [J]. CORNEA, 2003, 22 (07) : 640 - 650
  • [6] Bron AJ, 2007, OCUL SURF, V5, P108
  • [7] Importance of the lipid layer in human tear film stability and evaporation
    Craig, JP
    Tomlinson, A
    [J]. OPTOMETRY AND VISION SCIENCE, 1997, 74 (01) : 8 - 13
  • [8] Finnemore VM, 1998, ADV EXP MED BIOL, V438, P875
  • [9] Blinking and Tear Break-Up During Four Visual Tasks
    Himebaugh, Nikole L.
    Begley, Carolyn G.
    Bradley, Arthur
    Wilkinson, Jenni A.
    [J]. OPTOMETRY AND VISION SCIENCE, 2009, 86 (02) : 106 - 114
  • [10] The effect of instilled fluorescein solution volume on the values and repeatability of TBUT measurements
    Johnson, ME
    Murphy, PJ
    [J]. CORNEA, 2005, 24 (07) : 811 - 817