THE PROTOTYPE OF MICROWAVE-INDUCED THERMO-ACOUSTIC TOMOGRAPHY IMAGING BY TIME REVERSAL MIRROR

被引:22
|
作者
Chen, G. P. [1 ]
Yu, W. B. [1 ]
Zhao, Z. Q. [1 ]
Nie, Z. P. [1 ]
Liu, Q. H. [1 ,2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Elect Engn, Chengdu 610054, Peoples R China
[2] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27708 USA
关键词
D O I
10.1163/156939308786390021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Microwave-Induced Thermo-Acoustic Tomography (MITAT) is a promising technique in biologic tissue imaging. It has predominant advantages in both contrast and resolution compared with conventional microwave or ultrasound imaging system for malignant tumors. In this paper, an integrated prototype MITAT system is briefly introduced. And Time Reversal Mirror (TRM) imaging technique based on Pseudo-Spectrum Time Domain (PSTD) is also first time applied to MITAT system. Two tissue strips of porcine muscle are used as targets in the MITAT experiment to demonstrate the imaging potential of the system. TRM and Filtered Back-Projection (FBP) imaging results are both presented to compare the performance of the TRM and other imaging techniques in contrast and resolution for MITAT.
引用
收藏
页码:1565 / 1574
页数:10
相关论文
共 50 条
  • [1] Application of time reversal mirror technique in microwave-induced thermo-acoustic tomography system
    CHEN GuoPing1
    2 Department of Electrical and Computer Engineering
    Science in China(Series E:Technological Sciences), 2009, (07) : 2087 - 2095
  • [2] Application of time reversal mirror technique in microwave-induced thermo-acoustic tomography system
    Chen GuoPing
    Zhao ZhiQin
    Zheng WenJun
    Nie ZaiPing
    Liu QingHuo
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2009, 52 (07): : 2087 - 2095
  • [3] Application of time reversal mirror technique in microwave-induced thermo-acoustic tomography system
    GuoPing Chen
    ZhiQin Zhao
    WenJun Zheng
    ZaiPing Nie
    QingHuo Liu
    Science in China Series E: Technological Sciences, 2009, 52 : 2087 - 2095
  • [4] COMPUTATIONAL STUDY OF TIME REVERSAL MIRROR TECHNIQUE FOR MICROWAVE-INDUCED THERMO-ACOUSTIC TOMOGRAPHY
    Chen, G.
    Zhao, Z.
    Nie, Z.
    Liu, Q. H.
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2008, 22 (16) : 2191 - 2204
  • [5] Development of microwave-induced thermo-acoustic tomography prototype system
    CHEN GuoPing1
    2 Department of Electrical and Computer Engineering
    Science Bulletin, 2009, (23) : 4446 - 4450
  • [6] Development of microwave-induced thermo-acoustic tomography prototype system
    Chen GuoPing
    Zhao ZhiQin
    Gong Wei
    Nie ZaiPing
    Liu QingHuo
    CHINESE SCIENCE BULLETIN, 2009, 54 (23): : 4446 - 4450
  • [7] The application of time reversal mirror based on pseudo-spectrum time domain for microwave-induced thermo-acoustic tomography
    Chen, Guoping
    Yu, Wanbao
    Zhao, Zhiqin
    Nie, Zaiping
    Liu, Qing-H
    2008 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-9, 2008, : 3082 - 3085
  • [8] The Computational Study of Microwave-induced Thermo-Acoustic Tomography for Biologic Tissue Imaging Based on Pseudo-Spectrum Time Domain and Time Reversal Mirror technique
    Chen, Guoping
    Zhao, Zhiqin
    Liu, Qing H.
    MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2012, 195-196 : 353 - +
  • [9] S-band microwave-induced thermo-acoustic tomography system
    Du Jin-Song
    Yang, Gao
    Xin, Bi
    Qi Wei-Zhi
    Lin, Huang
    Jian, Rong
    ACTA PHYSICA SINICA, 2015, 64 (03)
  • [10] Thermo-Acoustic Imaging for Different Breast Tissues in Microwave Induced Thermo-Acoustic Tomography System
    Song, Jian
    Zhao, Zhiqin
    Wu, Jiangniu
    Zhu, Xiaozhang
    Nie, Zaiping
    Liu, Qing-Huo
    2013 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2013, : 2032 - +