A New Option for Intramedullary Fixation of Jones Fractures: The Charlotte™ Carolina™ Jones Fracture System

被引:28
|
作者
Nunley, James A., II [1 ]
Glisson, Richard R. [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
关键词
Metatarsal; Fracture; Screw; Jones Fracture;
D O I
10.3113/FAI.2008.1216
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A number of different screws are used for Jones fracture fixation in cases in which hastened healing is desirable or nonoperative treatment has failed. None of them were designed for this application, and consequently there is a lack of continuity in screw configuration and sizing that can force the use of a screw that is not optimally size-matched to the metatarsal. This can be particularly problematic in high-demand patients such as athletes, in whom screw fixation failure is more likely to occur. Application-specific screws available in graduated sizes are now an option. This study was designed to compare the bending fatigue resistance of the new screws with that of clinically-proven contemporary Jones fracture fixation screws. The results may provide a basis for,judging the probability of successful screw performance relative to the other established screw options. Materials and Methods: Bending fatigue resistance of the smallest-diameter Wright Medical Technologies Charlotte (TM) Carolina (TM) screw was compared to that of three commonly used contemporary screws. Cyclic three-point bending was applied to the screw shafts for 2,()110,000 cycles or until 5 mm of deflection occurred. Four to six samples of each screw were tested. Results: The number of load cycles withstood by the new screws greatly exceeded the number of cycles tolerated by Acutrak 4/5 screws, Synthes 4.5-mm malleolar screws, and Synthes 4.5 mm cannulated screws. Conclusion: The fatigue resistance of the smallest-diameter Charlotte (TM) Carolina (TM) screw exceeds that of other contemporary screws known to possess sufficient strength for Jones fracture fixation. Clinical Relevance: It is likely that this system of graduated-size screws may be implemented for treatment of acute Jones fractures without concern for device failure. Patients may benefit from more accurate matching of the screw size to the fractured metatarsal.
引用
收藏
页码:1216 / 1221
页数:6
相关论文
共 42 条
  • [31] Range limitation in hip internal rotation and fifth metatarsal stress fractures (Jones fracture) in professional football players
    Saita, Yoshitomo
    Nagao, Masashi
    Kawasaki, Takayuki
    Kobayashi, Yohei
    Kobayashi, Keiji
    Nakajima, Hiroki
    Takazawa, Yuji
    Kaneko, Kazuo
    Ikeda, Hiroshi
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (07) : 1943 - 1949
  • [32] Return to Play and Fracture Union After the Surgical Management of Jones Fractures in Athletes A Systematic Review and Meta-analysis
    Attia, Ahmed Khalil
    Taha, Tarek
    Kong, Geraldine
    Alhammoud, Abduljabbar
    Mahmoud, Karim
    Myerson, Mark
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (12) : 3422 - 3436
  • [33] Clinical results of trochanteric fractures treated with the TARGON® proximal femur intramedullary nailing fixation system
    Kawatani, Yosuke
    Nishida, Kimiaki
    Anraku, Yoshihisa
    Kunitake, Katsuhiko
    Tsutsumi, Yasujiro
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 : S22 - S27
  • [34] Biomechanical Comparison of Cannulated Screw Osteosynthesis With Tension-Band Wiring for Proximal Fractures of the Fifth Metatarsal (Jones Fracture)
    Unthan, Mark
    Graul, Isabel
    Hallbauer, Jakob
    Lindner, Robert
    Hofmann, Gunther O.
    Kohler, Felix C.
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (02) : 300 - 303
  • [35] Biomechanical Analysis of Conventional Partially Threaded Screws Versus Headless Compression Screws in Proximal Fifth Metatarsal (Jones) Fracture Fixation
    Lam, Kenrick
    Bui, Roger
    Morris, Randal
    Panchbhavi, Vinod
    FOOT & ANKLE SPECIALIST, 2021, 14 (06) : 509 - 514
  • [36] Internal fixation of dorsally comminuted fractures of the distal part of the radius: a biomechanical analysis of volar plate and intramedullary nail fracture stability
    Konstantinidis, Lukas
    Helwig, Peter
    Seifert, Judith
    Hirschmueller, Anja
    Liodakis, Emmanouil
    Suedkamp, Norbert Paul
    Oberst, Michael
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1529 - 1537
  • [37] Fifth metatarsal Jones fracture fixation with a 4.5-mm cannulated stainless steel screw in the competitive and recreational athlete - A clinical and radiographic evaluation
    Porter, DA
    Duncan, M
    Meyer, SJF
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (05) : 726 - 733
  • [38] Safe intramedullary fixation of displaced midshaft clavicle fractures with 2.5 mm Kirschner wires - technique description and a two-part versus multifragmentary fracture fixation outcome comparison
    Bakota, Bore
    Chan, Gareth
    Staresinic, Mario
    Rajput, Vishal
    Phadnis, Joideep
    Korac, Zelimir
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S27 - S33
  • [39] Retrograde fixation of distal femoral fractures: Results using a new nail system
    Seifert, J
    Stengel, D
    Matthes, G
    Hinz, P
    Ekkernkamp, A
    Ostermann, PAW
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (07) : 488 - 495
  • [40] RETRACTED: Analysis of compression forces between varying sizes of cannulated screws versus rail external fixation for treatment of Jones type fifth metatarsal fracture (Retracted Article)
    Freschi, Scot A.
    Vardaxis, Vassilios
    Dodson, Nic
    JOURNAL OF FOOT & ANKLE SURGERY, 2008, 47 (04) : 295 - 298