A New Option for Intramedullary Fixation of Jones Fractures: The Charlotte™ Carolina™ Jones Fracture System

被引:28
|
作者
Nunley, James A., II [1 ]
Glisson, Richard R. [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
关键词
Metatarsal; Fracture; Screw; Jones Fracture;
D O I
10.3113/FAI.2008.1216
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A number of different screws are used for Jones fracture fixation in cases in which hastened healing is desirable or nonoperative treatment has failed. None of them were designed for this application, and consequently there is a lack of continuity in screw configuration and sizing that can force the use of a screw that is not optimally size-matched to the metatarsal. This can be particularly problematic in high-demand patients such as athletes, in whom screw fixation failure is more likely to occur. Application-specific screws available in graduated sizes are now an option. This study was designed to compare the bending fatigue resistance of the new screws with that of clinically-proven contemporary Jones fracture fixation screws. The results may provide a basis for,judging the probability of successful screw performance relative to the other established screw options. Materials and Methods: Bending fatigue resistance of the smallest-diameter Wright Medical Technologies Charlotte (TM) Carolina (TM) screw was compared to that of three commonly used contemporary screws. Cyclic three-point bending was applied to the screw shafts for 2,()110,000 cycles or until 5 mm of deflection occurred. Four to six samples of each screw were tested. Results: The number of load cycles withstood by the new screws greatly exceeded the number of cycles tolerated by Acutrak 4/5 screws, Synthes 4.5-mm malleolar screws, and Synthes 4.5 mm cannulated screws. Conclusion: The fatigue resistance of the smallest-diameter Charlotte (TM) Carolina (TM) screw exceeds that of other contemporary screws known to possess sufficient strength for Jones fracture fixation. Clinical Relevance: It is likely that this system of graduated-size screws may be implemented for treatment of acute Jones fractures without concern for device failure. Patients may benefit from more accurate matching of the screw size to the fractured metatarsal.
引用
收藏
页码:1216 / 1221
页数:6
相关论文
共 42 条
  • [1] Treatment of Jones Fracture Nonunion with Isolated Intramedullary Screw Fixation
    Thomas, James L.
    Davis, Barry C.
    JOURNAL OF FOOT & ANKLE SURGERY, 2011, 50 (05) : 566 - 568
  • [2] Return to Weightbearing and High-Impact Activities Following Jones Fracture Intramedullary Screw Fixation
    Bucknam, Ryan B.
    Scanaliato, John P.
    Kusnezov, Nicholas A.
    Heida, Kenneth A., Jr.
    Dunn, John C.
    Orr, Justin D.
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (04) : 379 - 386
  • [3] Biomechanical comparisons of FERI techniques with different type of intramedullary screws fixation for Jones fractures
    Su, Kuo-Chih
    Yen, Yu-Chun
    Wang, Chun-Hsiang
    Wang, Yi-Lun
    Wang, Shun-Ping
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [4] Closed Intramedullary Screw Fixation for Nonunion of Fifth Metatarsal Jones Fracture
    Habbu, Rohan A.
    Marsh, Robert S.
    Anderson, John G.
    Bohay, Donald R.
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (06) : 603 - 608
  • [5] Four Cases with Rare Complications of Intramedullary Screw Fixation for Jones Fracture
    Morimoto, Yusuke
    Komatsu, Taichi
    Tokuhashi, Yasuaki
    ACTA MEDICA OKAYAMA, 2020, 74 (06) : 537 - 544
  • [6] Radiographic Study of the Fifth Metatarsal for Optimal Intramedullary Screw Fixation of Jones Fracture
    Ochenjele, George
    Ho, Bryant
    Switaj, Paul J.
    Fuchs, Daniel
    Goyal, Nitin
    Kadakia, Anish R.
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (03) : 293 - 301
  • [7] Rate of Delayed Union With Early Weightbearing Following Intramedullary Screw Fixation of Jones Fractures
    Looney, Austin M.
    Renehan, John R.
    Dean, Daniel M.
    Murthy, Anu
    Sanders, Thomas H.
    Neufeld, Steven K.
    Cuttica, Daniel J.
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (11) : 1325 - 1334
  • [8] Intramedullary Screw Fixation for Chronic Proximal Fourth Metatarsal Stress Fractures: A New Technique for the Fourth Metatarsal "Jones''
    Porter, David A.
    Foulk, David M.
    Rund, Angela M.
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2010, 9 (03): : 147 - 153
  • [9] Evaluation of Two Types of Intramedullary Jones Fracture Fixation in a Cyclic and Ultimate Load Model
    Willegger, Madeleine
    Benca, Emir
    Hirtler, Lena
    Kasparek, Maximilian F.
    Bauer, Gregor
    Zandieh, Shahin
    Windhager, Reinhard
    Schuh, Reinhard
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (04) : 911 - 917
  • [10] Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture
    Huh, Jeannie
    Glisson, Richard R.
    Matsumoto, Takumi
    Easley, Mark E.
    FOOT & ANKLE INTERNATIONAL, 2016, 37 (04) : 411 - 418