Evaluation of the stiffness characteristics of square pore CoCrMo cellular structures manufactured using laser melting technology for potential orthopaedic applications

被引:92
作者
Hazlehurst, Kevin [1 ]
Wang, Chang Jiang [1 ]
Stanford, Mark [1 ]
机构
[1] Wolverhampton Univ, Dept Engn, Telford TF2 9NT, Shrops, England
来源
MATERIALS & DESIGN | 2013年 / 51卷
关键词
Cellular structures; Laser melting; Effective elastic modulus; Orthopaedic implants; BIOMEDICAL APPLICATIONS; MESH ARRAYS; TI-6AL-4V; TITANIUM; BONE; IMPLANTS; BEHAVIOR; DESIGN; STEM;
D O I
10.1016/j.matdes.2013.05.009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to improve the stress shielding characteristics of orthopaedic devices implants that mimic the mechanical behaviour of bone need to be considered. Additive layer manufacturing processes provide a capability to produce orthopaedic implants with tailored mechanical properties. In this work cobalt chrome molybdenum cellular structures have been designed and manufactured using selective laser melting, with volume based porosity ranging between 25% and 95%. The effective mechanical properties have been determined through uniaxial compression testing and compared to numerical and analytical predictions where differences were observed. Cellular structures have been presented that exhibit similar stiffness and strength characteristics when compared to cortical and cancellous bone in the human femur. An expression has been proposed to predict the effective elastic modulus of cobalt chrome molybdenum cellular structures with volumetric porosity of 65% and above. A finite element modelling technique has been used to demonstrate that structural variation and heterogeneities that are associated with the manufacture of cellular structures can significantly decrease the effective stiffness. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:949 / 955
页数:7
相关论文
共 24 条
[1]  
[Anonymous], 2012, 133142011 BS ISO
[2]   Medical design: Direct metal laser sintering of Ti-6Al-4V [J].
Bertol, Liciane Sabadin ;
Kindlein Junior, Wilson ;
da Silva, Fabio Pinto ;
Aumund-Kopp, Claus .
MATERIALS & DESIGN, 2010, 31 (08) :3982-3988
[3]  
Electro Optical Systems, 2006, MAT DAT SHEET EOS CO
[4]   Laser Additive Manufacturing of Modified Implant Surfaces with Osseointegrative Characteristics [J].
Emmelmann, C. ;
Scheinemann, P. ;
Munsch, M. ;
Seyda, V. .
LASERS IN MANUFACTURING 2011: PROCEEDINGS OF THE SIXTH INTERNATIONAL WLT CONFERENCE ON LASERS IN MANUFACTURING, VOL 12, PT A, 2011, 12 :375-384
[5]   Mechanical and microstructural properties of polycaprolactone scaffolds with one-dimensional, two-dimensional, and three-dimensional orthogonally oriented porous architectures produced by selective laser sintering [J].
Eshraghi, Shaun ;
Das, Suman .
ACTA BIOMATERIALIA, 2010, 6 (07) :2467-2476
[6]  
Gibson L. J., 1997, CELLULAR SOLIDS STRU, V2nd ed
[7]   Effects of Materials of Cementless Femoral Stem on the Functional Adaptation of Bone [J].
Gong, He ;
Wu, Wei ;
Fang, Juan ;
Dong, Xin ;
Zhao, Meisheng ;
Guo, Tongtong .
JOURNAL OF BIONIC ENGINEERING, 2012, 9 (01) :66-74
[8]   Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology [J].
Harrysson, Ola L. A. ;
CansiZoglu, Omer ;
Marcellin-Little, Denis J. ;
Cormier, Denis R. ;
West, Harvey A., II .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (03) :366-373
[9]   Mathematical optimization of elastic properties: Application to cementless hip stem design [J].
Kuiper, JH ;
Huiskes, R .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :166-174
[10]   Compression fatigue behavior of Ti-6Al-4V mesh arrays fabricated by electron beam melting [J].
Li, S. J. ;
Murr, L. E. ;
Cheng, X. Y. ;
Zhang, Z. B. ;
Hao, Y. L. ;
Yang, R. ;
Medina, F. ;
Wicker, R. B. .
ACTA MATERIALIA, 2012, 60 (03) :793-802