Studying the response of CR-39 to radon in non-polar liquids above water by Monte Carlo simulation and measurement

被引:6
作者
Rezaie, Mohammad Reza [1 ]
Sohrabi, Mehdi [2 ]
Negarestani, Ali [1 ]
机构
[1] Kerman Grad Univ Technol & Adv Technol, Dept Phys, Kerman, Iran
[2] Amirkabir Univ Technol, Dept Phys, Hlth Phys & Dosimetry Res Lab, Tehran, Iran
关键词
Radon; Water; Measurement; New method; Two-phase media; CR-39; Alpha tracks; Sensitivity; Monte Carlo; Simulation; Air; Cyclohexane; Hexane; Olive oil; RA-226; RN-222; SUPPLIES; DETECTOR; ENERGY; TRACKS; SYSTEM;
D O I
10.1016/j.radmeas.2012.11.024
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The application of CR-39 has been extensive for measurement of radon and progeny in air of dwellings, but limited as regards to measurements of radon in water. In this paper, a new method is introduced for efficient measurement of radon in water by registering alpha particle tracks in a CR-39 detector placed in a non-polar medium such as cyclohexane, hexane and olive oil when each mixed with water, then separated and fixed above water, as a two-phase media. The method introduced here is however different from the widely used liquid - liquid extraction technique by liquid scintillation spectrometry since it is a passive detection method (CR-39) in a non-polar liquid with enhanced absorption of radon in the liquid, it has a capability for long sample counting to decrease the minimum detection limit (MDL), it does not require sophisticated low light counting systems, and it has the potential for simultaneous measurements of large number of samples for large-scale applications. It also has a low cost and is readily available. A new Monte Carlo calculation of energy-distance travelled by alphas from radon and progeny in a medium was also investigated. The sensitivity of CR-39 detector to radon and progeny in water was determined under two conditions; in a single-phase and two-phase media. In a single-phase medium, CR-39 is directly placed either in air, water, cyclohexane, hexane or olive oil. When CR-39 is placed directly in water, its sensitivity is (2.4 +/- 0.1) x 10(-4) (track/cm(2))/(Bq.d/m(3)). In the two-phase media, CR-39 is placed either in cyclohexane, hexane or olive oil when each is fixed above water. The sensitivities in the two-phase media are significantly enhanced and are respectively (1.98 +/- 0.10) x 10(-2), (2.8 +/- 0.15) x 10(-2) and (2.86 +/- 0.15) x 10(-2) (track/cm(2))/(Bq.d/m(3)). The sensitivies are about 76, 82 and 110 times more than that of when CR-39 is directly placed in water. The new method is a novel alternative for radon measurements in water with a lower MDL than that of for example liquid scintillation method with a number of advantages. The results are presented and discussed. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 29 条
[1]   Automation system for optical counting of nuclear tracks [J].
Boulyga, SF ;
Boulyga, EG ;
Lomonosova, EM ;
Zhuk, IV .
RADIATION MEASUREMENTS, 1999, 31 (1-6) :237-240
[2]  
Cigna A.A., 2005, Int. J. Speleol, V34, P1, DOI DOI 10.5038/1827-806X.34.1.1
[3]   Measurement of 222Rn and 226Ra in water by absorption of radon in polycarbonates and etching alpha-tracks [J].
Dimitrova, I. ;
Mitev, K. ;
Pressyanov, D. ;
Georgiev, S. ;
Boshkova, T. .
RADIATION MEASUREMENTS, 2011, 46 (01) :119-126
[4]   Automating radon solid state track detector measurements [J].
Fairchild, Robert ;
Tjong, Lydiawati ;
Wright, Tracy .
RADIATION MEASUREMENTS, 2011, 46 (12) :1773-1777
[5]  
FROMM M, 1988, NUCL TRACKS RAD MEAS, V15, P115
[6]   Digital imaging system for track measurements [J].
Gammage, RB ;
Espinosa, G .
RADIATION MEASUREMENTS, 1997, 28 (1-6) :835-838
[7]   Solubility and distribution of radon in organic solvents [J].
Kal'muk, S. D. ;
Makitra, R. G. ;
Pal'chikova, E. Ya. .
RUSSIAN JOURNAL OF GENERAL CHEMISTRY, 2007, 77 (04) :503-508
[8]   Monte Carlo computation of the calibration factor for Rn-222 measurements with electrochemically etched polycarbonate nuclear track detectors [J].
Kappel, RJA ;
Keller, G ;
Nickels, RM ;
Leiner, U .
RADIATION PROTECTION DOSIMETRY, 1997, 71 (04) :261-268
[9]   Studying the response of CR-39 detectors using the Monte Carlo technique [J].
Khan, RFH ;
Ahmad, N ;
Aslam ;
Matiullah .
RADIATION MEASUREMENTS, 2001, 33 (01) :129-137
[10]  
Law Y.L., 2008, RADIAT MEAS, V43, P128