Gas chromatography-mass spectrometry of the trimethylsilyl (oxime) ether/ester derivatives of cholic acids: Their presence in the aquatic environment

被引:14
|
作者
Sebok, A. [1 ,2 ]
Sezerc, K. [3 ]
Vasanits-Zsigrai, A. [1 ,2 ]
Helenkar, A. [1 ,2 ]
Zaray, Gy. [1 ]
Molnar-Perl, I. [1 ]
机构
[1] Eotvos Lorand Univ, Inst Chem, Dept Analyt Chem, H-1117 Budapest, Hungary
[2] Cooperat Res Ctr Environm Sci, H-1518 Budapest, Hungary
[3] Trakya Univ, Dept Chem, TR-22030 Edirne, Turkey
关键词
Cholic acids; Gas chromatography-mass spectrometry; Oximation; Trimethylsilylation; Fragmentation patterns; Aquatic environmental pollutant;
D O I
10.1016/j.chroma.2008.09.079
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a derivatization, mass fragmentation study relating to the most common six cholic acids, such as cholic, lithocholic, chenodeoxycholic, Ursodeoxycholic, 3-hydroxy,7-ketocholanic and dehydrocholic acids, identified and quantified as pollutants in the aquatic environment at the first time. Derivatizations have been performed with the two-step process (1: oximation, 2: silylation) varying the time and temperature of both reactions. Optimum responses have been obtained after 30 min oximation with hydroxylamine HCl and 90 min silylation with hexamethyldisilazane and trifluoroacetic acid at 70 degrees C. Fragmentation patterns of the trimethylsilyl (oxime) ether/ester derivatives Of all six cholic acids provided the theoretically expected, fully derivatized compounds. Reproclucibility/linearity of derivatives calculated oil the basis of the corresponding selective fragment ions, characterized by the relative standard deviation percentages of measurements, proved to be <= 4.9(RSD%). The practical utility of the method was shown by the identification and quantification of cholic acids as pollutants in the aquatic environment. Subsequently to a solid phase extraction study varying the pH of extractions (pH 2, pH 4 and pH 7), applying the OASIS cartridges, it has been confirmed that the recoveries for all six cholic acids are acceptable, varying between 77% and 104%, and are independent on the pH. The total cholic acid content of a Hungarian wastewater plants' influent wastewater varied between 184 mu g/L and 356 mu g/L, while the Danube rivers' cholic acid content was 4.1 mu g/L, only. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 50 条
  • [41] Identification of Water-Soluble Sulfonic Acids Isolated from Acid Tars by Gas Chromatography-Mass Spectrometry
    Zhebryakov, E., V
    Zorin, A. D.
    Zanozina, V. F.
    Gushchina, E. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (01) : 90 - 94
  • [42] Quantification of Free Short-Chain Fatty Acids in Raw Cow Milk by Gas Chromatography-Mass Spectrometry
    Wu, Xufang
    Wang, Fengen
    Chen, Meiqing
    Wang, Jiaqi
    Zhang, Yangdong
    FOODS, 2023, 12 (07)
  • [43] Neurochemical study of amino acids in rodent brain structures using an improved gas chromatography-mass spectrometry method
    Xavier Pinto, Mauro Cunha
    Nunes de Paiva, Maria Jose
    Oliveira-Lima, Onesia Cristina
    Menezes, Helvecio Costa
    Cardeal, Zenilda de Lourdes
    Gomez, Marcus Vinicius
    Resende, Rodrigo Ribeiro
    Gomez, Renato Santiago
    JOURNAL OF CHEMICAL NEUROANATOMY, 2014, 55 : 24 - 37
  • [44] Static headspace-gas chromatography-mass spectrometry for the simultaneous determination of trihalomethanes and haloacetic acids in canned vegetables
    Jose Cardador, Maria
    Gallego, Mercedes
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1454 : 9 - 14
  • [45] The use of trimethylsilyl cyanide derivatization for robust and broad-spectrum high-throughput gas chromatography-mass spectrometry based metabolomics
    Khakimov, Bekzod
    Motawia, Mohammed Saddik
    Bak, Soren
    Engelsen, Soren Balling
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (28) : 9193 - 9205
  • [46] Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine
    Cha, Eunju
    Jeong, Eun Sook
    Cha, Sangwon
    Lee, Jaeick
    ANALYTICA CHIMICA ACTA, 2017, 964 : 123 - 133
  • [47] Identification and quantification of ibuprofen, naproxen, ketoprofen and diclofenac present in waste-waters, as their trimethylsilyl derivatives, by gas chromatography mass spectrometry
    Sebok, A.
    Vasanits-Zsigrai, A.
    Palko, Gy.
    Zaray, Gy.
    Molnar-Perl, I.
    TALANTA, 2008, 76 (03) : 642 - 650
  • [48] Application of solid-phase extraction membrane disks in the determination of haloacetic acids in water by gas chromatography-mass spectrometry
    D. Martínez
    F. Borrull
    M. Calull
    J. Ruana
    A. Colom
    Chromatographia, 1998, 48 : 811 - 816
  • [49] Semiautomated solid-phase extraction followed by derivatisation and gas chromatography-mass spectrometry for determination of perfluoroalkyl acids in water
    Jurado-Sanchez, Beatriz
    Ballesteros, Evaristo
    Gallego, Mercedes
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1318 : 65 - 71
  • [50] Metabolic Profiling of Aliphatic, hydroxy, and Methyl-Branched Fatty Acids in Human Plasma by Gas Chromatography-Mass Spectrometry
    Seo, Chan
    Kim, Youngbae
    Lee, Hyeon-Seong
    Kim, Sook Za
    Paik, Man-Jeong
    ANALYTICAL LETTERS, 2018, 51 (06) : 793 - 806