Diagnostic value of cadmium-zinc-telluride myocardial perfusion imaging versus coronary angiography in coronary artery disease A PRISMA-compliant meta-analysis

被引:11
作者
Zhang, Yi-Qing [1 ]
Jiang, Yu-Feng [1 ]
Hong, Lu [1 ]
Chen, Min [1 ]
Zhang, Nan-Nan [1 ]
Yang, Hua-Jia [1 ]
Zhou, Ya-Feng [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Dept Cardiol, 188 Shizi Rd, Suzhou 215006, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
angiography; CZT-MPI; meta-analysis; EMISSION COMPUTED-TOMOGRAPHY; EFFICIENCY SPECT MPI; GAMMA-CAMERA; AUTOMATED QUANTIFICATION; SYSTEMATIC REVIEWS; COMBINED SUPINE; ACCURACY; ACQUISITION; COLLIMATION; TECHNOLOGY;
D O I
10.1097/MD.0000000000014716
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Rapid progress has been made in research of cadmium-zinc-telluride (CZT) technology in the last few years, which might serve as a new method to diagnose coronary artery disease. However, compared with coronary angiography, the diagnostic value of CZT is still controversial. We aimed to evaluate diagnosis value of coronary angiography versus CZT in coronary artery disease. Methods: We searched the database for eligible researches associated with CZT- myocardial perfusion imaging (MPI) and invasive coronary angiography, extracted the relevant data, and rigorously screened it according to the inclusion and exclusion criteria. The accuracy indicators included sensitivity, specificity, accuracy, positive and negative likelihood ratios. Results: According to the inclusion and exclusion criteria, we finally found 20 studies containing 2350 patients in this search. Pooled results showed that sensitivity of CZT-MPI was 0.84% and 95% confidence interval (95% CI): 0.78 to 0.89, specificity was 0.72, 95% CI (0.62-0.76), the specificity was lower apparently. The positive likelihood ratio was 3.0, 95% CI (2.4-3.8), the negative likelihood ratio was 0.22, 95% CI (0.16-0.31), diagnostic odds ratio was 14, 95% CI (7.84-17.42). Conclusion: This meta-analysis showed that CZT-MPI had satisfactory sensitivity and specificity for diagnosing coronary artery disease. Larger studies are required for further evaluation.
引用
收藏
页数:10
相关论文
共 37 条
  • [1] First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study
    Agostini, Denis
    Roule, Vincent
    Nganoa, Catherine
    Roth, Nathaniel
    Baavour, Raphael
    Parienti, Jean-Jacques
    Beygui, Farzin
    Manrique, Alain
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (07) : 1079 - 1090
  • [2] [Anonymous], 2010, INT J SURG, DOI [DOI 10.1016/j.ijsu.2010.02.007, 10.1371/journal.pmed.1000097, DOI 10.1371/JOURNAL.PMED.1000097]
  • [3] Barone-Rochette G, 2018, J NUCL CARDIOL
  • [4] Clinical value of supine and upright myocardial perfusion imaging in obese patients using the D-SPECT camera
    Ben-Haim, Simona
    Almukhailed, Omar
    Neill, Johanne
    Slomka, Piotr
    Allie, Rayjanah
    Shiti, Dalia
    Berman, Daniel S.
    Bomanji, Jamshed
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) : 478 - 485
  • [5] Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera
    Ben-Haim, Simona
    Kacperski, Krzysztof
    Hain, Sharon
    Van Gramberg, Dean
    Hutton, Brian F.
    Erlandsson, Kjell
    Sharir, Tali
    Roth, Nathaniel
    Waddington, Wendy A.
    Berman, Daniel S.
    Ell, Peter J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) : 1710 - 1721
  • [6] Stress Thallium-201/Rest Technetium-99m Sequential Dual Isotope High-Speed Myocardial Perfusion Imaging
    Berman, Daniel S.
    Kang, Xingping
    Tamarappoo, Balaji
    Wolak, Arik
    Hayes, Sean W.
    Nakazato, Ryo
    Thomson, Louise E. J.
    Kite, Faith
    Cohen, Ishac
    Slomka, Piotr J.
    Einstein, Andrew J.
    Friedman, John D.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2009, 2 (03) : 273 - 282
  • [7] Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies
    Borges-Neto, Salvador
    Pagnanelli, Robert A.
    Shaw, Linda K.
    Honeycutt, Emily
    Shwartz, Shuli C.
    Adams, George L.
    Coleman, Ralph Edward
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) : 555 - 565
  • [8] Rapid-acquisition myocardial perfusion scintigraphy (MPS) on a novel gamma camera using multipinhole collimation and miniaturized cadmiumzinctelluride (CZT) detectors: prognostic value and diagnostic accuracy in a real-world nuclear cardiology service
    Chowdhury, F. U.
    Vaidyanathan, S.
    Bould, M.
    Marsh, J.
    Trickett, C.
    Dodds, K.
    Clark, T. P. R.
    Sapsford, R. J.
    Dickinson, C. J.
    Patel, C. N.
    Thorley, P. J.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (03) : 275 - 283
  • [9] The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    Deeks, JJ
    Macaskill, P
    Irwig, L
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) : 882 - 893
  • [10] Conducting systematic reviews of diagnostic studies: Didactic guidelines
    Devillé W.L.
    Buntinx F.
    Bouter L.M.
    Montori V.M.
    De Vet H.C.W.
    Van Der Windt D.A.W.M.
    Bezemer P.D.
    [J]. BMC Medical Research Methodology, 2 (1) : 1 - 13