Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography

被引:0
|
作者
Cho, Pyong-Kon [1 ]
机构
[1] Catholic Univ Daegu, Dept Radiol Sci, Gyongsan, South Korea
关键词
LOW-TUBE VOLTAGE; CT;
D O I
10.1093/rpd/ncs153
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The primary goal of this study was to ascertain the reduction in radiation dose when conducting low-kilovoltage liver computed tomography (CT) examinations using multidetector row CT (MDCT). Fifty patients under follow-up who were diagnosed with liver cancer were examined using a 16-slice MDCT scanner and volume CT dose index (CTDIvol) measured according to the methods of examination, which were based on a three-phase CT scan conducted in the previous year and a four-phase CT scan was done a year later. Scanning parameters were 120 kV(p)140 mA s, 120 kV(p)120 mA s and 80 kV(p)280 mA s. The CTDIvol was decreased to 47 at 80 kV(p) 280 mA s. The results indicate that low-kilovoltage liver CT is a useful means of reducing radiation doses.
引用
收藏
页码:76 / 80
页数:5
相关论文
共 50 条
  • [1] Multidetector Computed Tomography Chest Examinations With Low-Kilovoltage Protocols in Adults: Effect on Image Quality and Radiation Dose
    Kim, Mi Jung
    Park, Chul Hi
    Choi, Soo Jin
    Hwang, Kyung Hoon
    Kim, Hyung Sik
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 416 - 421
  • [2] Errors in multidetector row computed tomography
    Mazzei, M. A.
    Volterrani, L.
    RADIOLOGIA MEDICA, 2015, 120 (09): : 785 - 794
  • [3] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [4] Radiation Dose Reduction in Cervical Spine Computed Tomography in Cervical Spine Trauma: Comparison of Low-dose with Standard-dose Multidetector Computed Tomography
    Man, K. Y.
    Mo, K. M.
    Sung, H. T.
    Cho, K. Y.
    Tam, C. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (03): : 180 - 187
  • [5] Automated Low-Kilovoltage Selection in Pediatric Computed Tomography Angiography Phantom Study Evaluating Effects on Radiation Dose and Image Quality
    Siegel, Marilyn Joy
    Ramirez-Giraldo, Juan Carlos
    Hildebolt, Charles
    Bradley, David
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 584 - 589
  • [6] Patient dose and image quality from the low kilovoltage dynamic liver computed tomography examinations
    Cho, Pyong-Kon
    Lee, Sung-Hyun
    Lee, Mi-Hwa
    Cho, Young-Kwon
    Chon, Kwon-Soo
    Kim, Yong-Min
    ASIAN BIOMEDICINE, 2013, 7 (01) : 119 - 124
  • [7] Multidetector computed tomography (MDCT) and dose reduction in pediatric radiology
    Heyer, C. M.
    MONATSSCHRIFT KINDERHEILKUNDE, 2011, 159 (04) : 343 - 349
  • [8] Multidetector-row computed tomography of thoracic trauma
    Kaewlai, R.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2011, 65 : 3 - 16
  • [9] Low radiation dose in computed tomography: the role of iodine
    Aschoff, Andrik J.
    Catalano, Carlo
    Kirchin, Miles A.
    Krix, Martin
    Albrecht, Thomas
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076):
  • [10] Helical Multidetector Row Quantitative Computed Tomography (QCT) Precision
    Bligh, Michael
    Bidaut, Luc
    White, R. Allen
    Murphy, William A., Jr.
    Stevens, Donna M.
    Cody, Dianna D.
    ACADEMIC RADIOLOGY, 2009, 16 (02) : 150 - 159