Sizing for Mitral Annuloplasty: Where Does Science Stop and Voodoo Begin?

被引:65
作者
Bothe, Wolfgang
Miller, D. Craig
Doenst, Torsten [1 ]
机构
[1] Univ Jena, Dept Cardiothorac Surg, Jena Univ Hosp, D-07747 Jena, Germany
关键词
OUTFLOW TRACT OBSTRUCTION; VALVE REPAIR; PAPILLARY-MUSCLE; LEAFLET PROLAPSE; REGURGITATION; RING; SURGERY; EXPERIENCE; DURABILITY; RELOCATION;
D O I
10.1016/j.athoracsur.2012.10.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implantation of an improperly sized annuloplasty ring may result in an incompetent valve after surgical mitral valve repair. Consequently, the procedure of ring size selection is considered critical. Although a plethora of sizing strategies are described, the opinions on how to select the appropriate ring size differ widely and often appear arbitrary (ie, without scientific justification). These inconsistencies raise the question where, with respect to ring sizing, science stops and voodoo begins. (Ann Thorac Surg 2013;95:1475-83) (c) 2013 by The Society of Thoracic Surgeons
引用
收藏
页码:1475 / 1483
页数:9
相关论文
共 63 条
  • [1] Acar C, 2004, J HEART VALVE DIS, V13, P741
  • [2] Large annuloplasty rings facilitate mitral valve repair in Barlow's disease
    Adams, David H.
    Anyanwu, Ani C.
    Rahmanian, Parwis B.
    Abascal, Vivian
    Salzberg, Sacha P.
    Filsoufi, Farzan
    [J]. ANNALS OF THORACIC SURGERY, 2006, 82 (06) : 2096 - 2101
  • [3] The double-orifice technique in mitral valve repair: A simple solution for complex problems
    Alfieri, O
    Maisano, F
    De Bonis, M
    Stefano, PL
    Torracca, L
    Oppizzi, M
    La Canna, G
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (04) : 674 - 681
  • [4] Modified technique for mitral repair without ring annuloplasty
    Barlow, CW
    Ali, ZA
    Lim, E
    Barlow, JB
    Wells, FC
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (01) : 298 - 300
  • [5] Chronic ischemic mitral regurgitation: Repair, replace or rethink?
    Borger, MA
    Alam, A
    Murphy, PM
    Doenst, T
    David, TE
    [J]. ANNALS OF THORACIC SURGERY, 2006, 81 (03) : 1153 - 1161
  • [6] Biological versus prosthetic ring in mitral-valve repair: enhancement of mitral annulus dynamics and left-ventricular function with pericardial annuloplasty at long term
    Borghetti, V
    Campana, M
    Scotti, C
    Domenighini, D
    Totaro, P
    Coletti, G
    Pagani, M
    Lorusso, R
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (04) : 431 - 438
  • [7] Effects of different annuloplasty rings on anterior mitral leaflet dimensions
    Bothe, Wolfgang
    Kvitting, John-Peder Escobar
    Swanson, Julia C.
    Hartnett, Sigurd
    Ingels, Neil B., Jr.
    Miller, D. Craig
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) : 1114 - 1122
  • [8] Preoperative left ventricular dimensions predict reverse remodeling following restrictive mitral annuloplasty in ischemic mitral regurgitation
    Braun, J
    Bax, JJ
    Versteegh, MIM
    Voigt, PG
    Holman, ER
    Klautz, RJM
    Boersma, E
    Dion, RAE
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (05) : 847 - 853
  • [9] Restrictive mitral annuloplasty cures ischemic mitral regurgitation and heart failur
    Braun, Jerry
    van de Veire, Nico R.
    Klautz, Robert J. M.
    Versteegh, Michel I. M.
    Holman, Eduard R.
    Westenberg, Jos J. M.
    Boersma, Eric
    van der Wall, Ernst E.
    Bax, Jeroen J.
    Dion, Robert A. E.
    [J]. ANNALS OF THORACIC SURGERY, 2008, 85 (02) : 430 - 437
  • [10] BURR LH, 1977, J THORAC CARDIOV SUR, V73, P589