Spectral Intensity Bioaerosol Sensor (SIBS): an instrument for spectrally resolved fluorescence detection of single particles in real time

被引:35
|
作者
Koenemann, Tobias [1 ]
Savage, Nicole [2 ,3 ]
Klimach, Thomas [1 ]
Walter, David [1 ]
Froehlich-Nowoisky, Janine [1 ]
Su, Hang [1 ]
Poeschl, Ulrich [1 ]
Huffman, J. Alex [2 ]
Poehlker, Christopher [1 ]
机构
[1] Max Planck Inst Chem, Multiphase Chem Dept, POB 3060, D-55020 Mainz, Germany
[2] Univ Denver, Dept Chem & Biochem, 2190 E Iliff Ave, Denver, CO 80208 USA
[3] Aerosol Devices Inc, 430 North Coll Ave 430, Ft Collins, CO 80524 USA
关键词
BIOLOGICAL AEROSOL-PARTICLES; AMAZON RAIN-FOREST; BACTERIOCHLOROPHYLL FLUORESCENCE; ATMOSPHERIC BIOAEROSOLS; AIRBORNE OBSERVATIONS; SIZE DISTRIBUTIONS; CLUSTER-ANALYSIS; UV-APS; CLASSIFICATION; SPECTROSCOPY;
D O I
10.5194/amt-12-1337-2019
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Primary biological aerosol particles (PBAPs) in the atmosphere are highly relevant for the Earth system, climate, and public health. The analysis of PBAPs, however, remains challenging due to their high diversity and large spatiotemporal variability. For real-time PBAP analysis, light-induced fluorescence (LIF) instruments have been developed and widely used in laboratory and ambient studies. The interpretation of fluorescence data from these instruments, however, is often limited by a lack of spectroscopic information. This study introduces an instrument - the Spectral Intensity Bioaerosol Sensor (SIBS; Droplet Measurement Technologies (DMT), Longmont, CO, USA) - that resolves fluorescence spectra for single particles and thus promises to expand the scope of fluorescent PBAP quantification and classification. The SIBS shares key design components with the latest versions of the Wideband Integrated Bioaerosol Sensor (WIBS) and the findings presented here are also relevant for the widely deployed WIBS-4A and WIBS-NEO as well as other LIF instruments. The key features of the SIBS and the findings of this study can be summarized as follows. Particle sizing yields reproducible linear responses for particles in the range of 300 nm to 20 mu m. The lower sizing limit is significantly smaller than for earlier commercial LIF instruments (e.g., WIBS-4A and the Ultraviolet Aerodynamic Particle Sizer; UV-APS), expanding the analytical scope into the accumulation-mode size range. Fluorescence spectra are recorded for two excitation wavelengths (lambda(ex) = 285 and 370 nm) and a wide range of emission wavelengths (lambda(mean) = 302-721 nm) with a resolution of 16 detection channels, which is higher than for most other commercially available LIF bioaerosol sensors. Fluorescence spectra obtained for 16 reference compounds confirm that the SIBS provides sufficient spectral resolution to distinguish major modes of molecular fluorescence. For example, the SIBS resolves the spectral difference between bacteriochlorophyll and chlorophyll a and b. A spectral correction of the instrument-specific detector response is essential to use the full fluorescence emission range. Asymmetry factor (AF) data were assessed and were found to provide only limited analytical information. In test measurements with ambient air, the SIBS worked reliably and yielded characteristically different spectra for single particles in the coarse mode with an overall fluorescent particle fraction of similar to 4% (3 sigma threshold), which is consistent with earlier studies in comparable environments.
引用
收藏
页码:1337 / 1363
页数:27
相关论文
共 50 条
  • [21] Time-resolved spectral method of magnetic-induction flaw detection of pipes in real time
    Akhmetshin, AM
    Gvozdak, AP
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2000, 36 (02) : 109 - 116
  • [22] Detection of intensity change points in time-resolved single-molecule measurements
    Watkins, LP
    Yang, H
    JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (01): : 617 - 628
  • [23] Single-Photon Avalanche Diode CMOS Sensor for Time-Resolved Fluorescence Measurements
    Stoppa, David
    Mosconi, Daniel
    Pancheri, Lucio
    Gonzo, Lorenzo
    IEEE SENSORS JOURNAL, 2009, 9 (09) : 1084 - 1090
  • [24] A 0.18-μm CMOS Array Sensor for Integrated Time-Resolved Fluorescence Detection
    Huang, Ta-chien D.
    Sorgenfrei, Sebastian
    Gong, Ping
    Levicky, Rastislav
    Shepard, Kenneth L.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (05) : 1644 - 1654
  • [25] A CMOS array sensor for sub-800-ps time-resolved fluorescence detection
    Huang, T.
    Sorgenfrei, S.
    Shepard, K. L.
    Gong, P.
    Levicky, R.
    PROCEEDINGS OF THE IEEE 2007 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2007, : 829 - +
  • [26] Homogeneous spectrally- and time-resolved fluorescence emission from single-tryptophan mutants of IIAGlc protein.
    Toptygin, D
    Savtchenko, RS
    Meadow, ND
    Brand, L
    BIOPHYSICAL JOURNAL, 2001, 80 (01) : 361A - 361A
  • [27] Spectrally resolved time-correlated single photon counting: a novel approach for characterization of endogenous fluorescence in isolated cardiac myocytes
    D. Chorvat
    A. Chorvatova
    European Biophysics Journal, 2006, 36 : 73 - 83
  • [28] Spectrally resolved time-correlated single photon counting: a novel approach for characterization of endogenous fluorescence in isolated cardiac myocytes
    Chorvat, D., Jr.
    Chorvatova, A.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2006, 36 (01): : 73 - 83
  • [29] Real-time measurement of fluorescence spectra from single airborne biological particles
    Hill, SC
    Pinnick, RG
    Niles, S
    Pan, YL
    Holler, S
    Chang, RK
    Bottiger, J
    Chen, BT
    Orr, CS
    Feather, G
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 1999, 3 (4-5): : 221 - 239
  • [30] A Reliable Fiber-Optic Temperature Sensor Based on Fluorescence Intensity Ratio Technique for Real-Time Human Thermal Detection
    Liu, Wei
    Tong, Xin
    Yin, Zhiyuan
    Zhang, Xuenan
    Yan, Xin
    Suzuki, Takenobu
    Ohishi, Yasutake
    Cheng, Tonglei
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2024, 42 (08) : 3045 - 3051