Comparison of dobutamine-stress magnetic resonance imaging and dipyridamole-Tl-201-SPECT as alternative strategies for the detection of coronary artery disease in patients not suitable for stress-echocardiography

被引:0
|
作者
Schmidt, M
Jochims, M
Theissen, P
Baer, FM
Crnac, J
Voth, E
Schneider, CA
Erdmann, E
Schicha, H
机构
[1] Univ Cologne, Nukl Med Klin & Poliklin, D-50924 Cologne, Germany
[2] Univ Cologne, Innere Med Klin 3, Cologne, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2001年 / 40卷 / 06期
关键词
coronary artery disease; stress-echocardiography; magnetic resonance imaging; myocardial scintigraphy; Tl-201-SPECT; pharmacological stress testing;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: During the past decade stress-echocardiography has gained increasing popularity for detection of myocardial ischemia in patients with coronary artery disease. However, about 10% to 15% of the patients submitted for stress-echocardiography do not have an adequate acoustic window. The purpose of this study was to compare high-dose dobutamine-stress magnetic resonance imaging (dobutamine-MRI) with dipyridamole-TI-201-SPECT (dipyridamole-SPECT) as alternative strategies for detection of myocardial ischemia in patients with inadequate image quality by stress-echocardiography. Patients and Methods: Of 296 patients which were consecutively submitted to stress-echocardiography 45 patients (15%) had two or more segments that could not be evaluated according to the 16-segment-model of the American Society of Echocardiography. They underwent dobutamine-MRI and dipyridamole-SPELT studies, which were evaluated using a 28-segment modell. Myocardial segments were attributed to perfusion territories of the coronary arteries. The results of ischemia detection were compared to the results of coronary angiography (stenosis greater than or equal to 50%) Results: In comparison to coronary angiography dobutamine-MRI yielded a sensitivity of 87%, a specificity of 86%, a positive predictive value of 93%, a negative predictive value of 75% and a diagnostic accuracy of 86%. For dipyridamole-SPELT results were 90%, 86%, 93%, 80% and 89%, respectively. These values were not significantly different. Conclusions: In patients not suitable for stress-echocardiography, both dobutamine-MRI and dipyridamole-SPELT are reliable strategies for detection of myocardial ischemia. Selection is dependent on the patient criteria, technical considerations, local logistics and experience of the observer.
引用
收藏
页码:198 / 206
页数:13
相关论文
共 50 条
  • [1] Simultaneous dobutamine stress echocardiography and thallium-201 perfusion imaging for the detection of coronary artery disease
    Huang, PJ
    Ho, YL
    Wu, CC
    Chao, CL
    Chen, MF
    Cheng, PU
    Lee, YT
    CARDIOLOGY, 1997, 88 (06) : 556 - 562
  • [2] Adenosine magnetic resonance imaging versus dobutamine stress echocardiography in patients with low probability for coronary artery disease
    Stamatios Lerakis
    Athanasios V Anadiotis
    Elisa Zaragoza-Macias
    Emir Veledar
    John Oshinski
    Chris Vaccari
    Akbar H Khan
    Puneet Sharma
    Irfan Shukrullah
    Paolo Raggi
    Arthur E Stillman
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [3] COMPARISON BETWEEN DOBUTAMINE STRESS ECHOCARDIOGRAPHY AND MYOCARDIAL PERFUSIONM IMAGING IN DETECTION OF CORONARY ARTERY DISEASE
    Khan, Sher Bahadar
    Zailb, Sultan
    Adil, Muhammad
    Shah, Syed Tahir
    Iqbal, Muhammad Asif
    Shahzeb
    Hafizullah, Mohammad
    PAKISTAN HEART JOURNAL, 2012, 45 (03): : 185 - 190
  • [4] Stress Perfusion Cardiac Magnetic Resonance vs SPECT Imaging for Detection of Coronary Artery Disease
    Arai, Andrew E.
    Schulz-Menger, Jeanette
    Shah, Dipan J.
    Han, Yuchi
    Bandettini, W. Patricia
    Abraham, Arun
    Woodard, Pamela K.
    Selvanayagam, Joseph B.
    Hamilton-Craig, Christian
    Tan, Ru-San
    Carr, James
    Teo, Lynette
    Kramer, Christopher M.
    Wintersperger, Bernd J.
    Harisinghani, Mukesh G.
    Flamm, Scott D.
    Friedrich, Matthias G.
    Klem, Igor
    Raman, Subha, V
    Haverstock, Daniel
    Liu, Zheyu
    Brueggenwerth, Guenther
    Santiuste, Marta
    Berman, Daniel S.
    Pennell, Dudley J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (19) : 1828 - 1838
  • [5] Parallel imaging and dobutamine stress magnetic resonance imaging in patients with atypical chest pain or equivocal ECG not suitable for stress echocardiography
    Di Cesare, E.
    Battisti, S.
    Riva, A.
    Corbacelli, C.
    De Bernardinis, G.
    Cicogna, S.
    Masciocchi, C.
    RADIOLOGIA MEDICA, 2009, 114 (02): : 216 - 228
  • [6] Comparison of thallium-201 exercise SPECT and dobutamine stress echocardiography for diagnosis of coronary artery disease in patients with left bundle branch block
    Tandogan, I
    Yetkin, E
    Yanik, A
    Ulusoy, FV
    Temizhan, A
    Cehreli, S
    Sasmaz, A
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (05): : 339 - 345
  • [7] Comparison of thallium-201 exercise SPECT and dobutamine stress echocardiography for diagnosis of coronary artery disease in patients with left bundle branch block
    Izzet Tandoğan
    Ertan Yetkin
    Ahmet Yanik
    F. Vasfi Ulusoy
    Ahmet Temizhan
    Sengül Cehreli
    Ali Sasmaz
    The International Journal of Cardiovascular Imaging, 2001, 17 : 339 - 345
  • [8] RATIO OF LUNG TO HEART TL-201 UPTAKE ON EXERCISE AND DIPYRIDAMOLE STRESS IMAGING IN CORONARY-ARTERY DISEASE - IMPLICATION OF SPECT
    TAKEISHI, Y
    CHIBA, J
    ABE, S
    TOMOIKE, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1993, 57 (05): : 379 - 387
  • [9] The Role of Dobutamine Stress Magnetic Resonance Imaging in the Clinical Management of Patients with Coronary Artery Disease
    Gebker, Rolf
    Jahnke, Cosima
    Kelle, Sebastian
    Klein, Christoph
    Manka, Robert
    Hucko, Thomas
    Schnackenburg, Bernhard
    Fleck, Eckart
    Paetsch, Ingo
    CIRCULATION, 2010, 122 (21)
  • [10] DOBUTAMINE STRESS ECHOCARDIOGRAPHY COMPARED WITH DIPYRIDAMOLE TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN DETECTING CORONARY-ARTERY DISEASE
    HO, FM
    HUANG, PJ
    LIAU, CS
    LEE, FK
    CHIENG, PU
    SU, CT
    LEE, YT
    EUROPEAN HEART JOURNAL, 1995, 16 (04) : 570 - 575