Parapapillary atrophy and optic disc region assessment (PANDORA): retinal imaging tool for assessment of the optic disc and parapapillary atrophy

被引:10
|
作者
Lu, Cheng-Kai [2 ]
Tang, Tong Boon [1 ]
Laude, Augustinus [3 ]
Dhillon, Baljean
Murray, Alan F. [2 ]
机构
[1] Univ Teknol PETRONAS, Ctr Intelligent Signal & Imaging Res, Tronoh 31750, Perak, Malaysia
[2] Univ Edinburgh, Sch Engn, Edinburgh EH8 9YL, Midlothian, Scotland
[3] Tan Tock Seng Hosp, Natl Healthcare Grp Eye Inst, Singapore, Singapore
关键词
parapapillary atrophy; optic disc; retinal image analysis; FUNDUS IMAGES; VESSEL SEGMENTATION; FEATURE-EXTRACTION; DIAGNOSIS; MODEL;
D O I
10.1117/1.JBO.17.10.106010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a computer-aided measuring tool, named parapapillary atrophy and optic disc region assessment (PANDORA), for automated detection and quantification of both the parapapillary atrophy (PPA) and the optic disc (OD) regions in two-dimensional color retinal fundus images. The OD region is segmented using a combination of edge detection and ellipse fitting methods. The PPA region is identified by the presence of bright pixels in the temporal zone of the OD, and it is segmented using a sequence of techniques, including a modified Chan-Vese approach, thresholding, scanning filter, and multiseed region growing. PANDORA has been tested with 133 color retinal images (82 with PPA; 51 without PPA) drawn randomly from the Lothian Birth Cohort (LBC) database, together with a "ground truth" estimate from an ophthalmologist. The PPA detection rate is 89.47% with a sensitivity of 0.83 and a specificity of 1. The mean accuracy in defining the OD region is 81.31% (SD = 10.45) when PPA is present and 95.32% (SD = 4.36) when PPA is absent. The mean accuracy in defining the PPA region is 73.57% (SD = 11.62). PANDORA demonstrates for the first time how to quantify the OD and PPA regions using two-dimensional fundus images, enabling ophthalmologists to study ocular diseases related to PPA using a standard fundus camera. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.10.106010]
引用
收藏
页数:8
相关论文
共 44 条
  • [31] Assessment of stereoscopic optic disc images using an autostereoscopic screen – experimental study
    Maged S Habib
    James A Lowell
    Nick S Holliman
    Andrew Hunter
    Daniella Vaideanu
    Anthony Hildreth
    David HW Steel
    BMC Ophthalmology, 8
  • [32] Assessment of the Optic Nerve Disc and Excavation Parameters of Interactive and Automated Parameterization Methods
    Buteikiene, Dovile
    Paunksnis, Alvydas
    Barzdziukas, Valerijus
    Bernataviciene, Jolita
    Marcinkevicius, Virginijus
    Treigys, Povilas
    INFORMATICA, 2012, 23 (03) : 335 - 355
  • [33] Beta-peripapillary atrophy of the optic disc and its determinants in Japanese eyes: a population-based study
    Mataki, Naomi
    Tomidokoro, Atsuo
    Araie, Makoto
    Iwase, Aiko
    ACTA OPHTHALMOLOGICA, 2018, 96 (06) : E701 - E706
  • [34] An Efficient Automatic Method of Optic Disc Segmentation using Region Growing Technique in Retinal Images
    Singh, Anushikha
    Dutta, Malay Kishore
    Parthasarathi, M.
    Burget, Radim
    Riha, Kamil
    2014 INTERNATIONAL CONFERENCE ON CONTEMPORARY COMPUTING AND INFORMATICS (IC3I), 2014, : 480 - 484
  • [35] A Neural Network-based Retinal Imaging Interface for Optic Disc Localization in Ophthalmic Analyses
    Carnimeo, Leonarda
    Benedetto, Anna Cinzia
    Nitti, Rosamaria
    2015 6TH IEEE INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES (IWASI), 2015, : 204 - 209
  • [36] The sensitivity and specificity of direct ophthalmoscopic optic disc assessment in screening for glaucoma: a multivariate analysis
    R. Harper
    Barnaby Reeves
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 949 - 955
  • [37] Assessment of the effects of vitreopapillary adhesion on optic disc and macular parameters, and peripapillary choroidal vasculature
    Ayhan, Ziya
    Kahraman, Hazan Gul
    Kiyat, Pelin
    Karti, Omer
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [38] COMPARISON OF ACCURACY IN ARTIFICIAL BEE COLONY ALGORITHM AND BAT ALGORITHM FOR THE DETECTION OF OPTIC DISC IN RETINAL FUNDUS IMAGING
    Arun, S.
    Priya, M. Vishnu
    INTERNATIONAL JOURNAL OF EARLY CHILDHOOD SPECIAL EDUCATION, 2022, 14 (03) : 5676 - 5687
  • [39] Correlation of central corneal thickness and axial length to the optic disc and peripapillary atrophy among healthy individuals, glaucoma and ocular hypertension patients
    Tomais, George
    Georgopoulos, Gerasimos
    Koutsandrea, Chryssanthi
    Moschos, Michalis
    CLINICAL OPHTHALMOLOGY, 2008, 2 (04): : 981 - 988
  • [40] Agreement between ophthalmologists and optometrists in optic disc assessment: training implications for glaucoma co-management
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 342 - 350