Reliability and Validity of the Velotron Racermate Cycle Ergometer to Measure Anaerobic Power

被引:26
|
作者
Astorino, T. A. [1 ]
Cottrell, T. [1 ]
机构
[1] Calif State Univ San Marcos, San Marcos, CA 92096 USA
关键词
Wingate test; PCr; fatigue index; supramaximal exercise; WINGATE; PERFORMANCE; SPORT;
D O I
10.1055/s-0031-1291219
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study assessed the reliability and validity of the Velotron Racermate (TM) cycle ergometer to assess anaerobic power. Men (9 cyclists and 13 recreationally-active) and women (17 recreationally-active and 1 cyclist) (age=24.7 +/- 4.2 yr) performed 2 Wingate tests on the Velotron or 3 Wingate tests (2 on the Velotron and 1 on the Monark Peak Bike) over a 7-14 day period. Peak power, mean power, minimum power, fatigue index, heart rate, and peak and minimum cadence were assessed. Results revealed significant test-retest reliability for mean power (r=0.90, p<0.01), minimum power (r=0.79, p<0.05) and peak power (r=0.70, p<0.05) with repeated bouts on the Velotron. Peak power was significantly higher (p<0.05) on the Velotron (9.95 +/- 1.39 W/kg) vs. the Monark (9.13 +/- 1.26 W/kg); however, mean power was higher (p<0.05) on the Monark (6.95 +/- 0.89 W/kg) vs. the Velotron (6.11 +/- 0.52 W/kg and 6.25 +/- 0.59 W/kg). Data reveal significant reliability for mean and peak power from the Velotron Racermate, yet multiple variables differ between the Velotron and the Monark mechanically-braked cycle ergometer.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [31] Reliability and Validity of a New Portable Tethered Sprint Running Test as a Measure of Maximal Anaerobic Performance
    Limmer, Mirjam
    Berkholz, Alina
    de Marees, Markus
    Platen, Petra
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2020, 34 (08) : 2197 - 2204
  • [32] Significance of Cycle Ergometer as a Measure of Peak Aerobic Capacity in the Disabled
    Yoon, Ho Min
    Han, Eun Young
    Joo, Seung-Jae
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (02):
  • [33] Reliability and Validity of the Sit-to-Stand as a Muscular Power Measure in Older Adults
    Sherwood, Jennifer J.
    Inouye, Cathy
    Webb, Shannon L.
    Jenny, O.
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2020, 28 (03) : 455 - 466
  • [34] A new instrument to measure patient satisfaction with mammography - Validity, reliability, and discriminatory power
    Loeken, K
    Steine, S
    Sandvik, L
    Laerum, E
    MEDICAL CARE, 1997, 35 (07) : 731 - 741
  • [35] DETERMINATION OF MAXIMAL AEROBIC AND ANAEROBIC POWER ON CYCLE ERGOMETER - MARK OF GENERAL PHYSICAL VALUE AND DIFFERENTIAL FITNESS RATIO
    BRUE, F
    MONTMAYEUR, A
    MELIN, B
    LAMANDE, JP
    BAGOT, L
    MEDECINE ET ARMEES, 1988, 16 (08): : 599 - 604
  • [36] Anaerobic Threshold Determination in Cycle Ergometer From Rating of Perceived Exertion
    dos Santos, Geovani Alves
    Numata-Filho, Eduardo Seiji
    Rosa, Thiago dos Santos
    Passos Neves, Rodrigo Vanerson
    Simoes, Herbert Gustavo
    Moreira, Sergio Rodrigues
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (05) : 1277 - 1281
  • [37] RELIABILITY AND VALIDITY OF THE LANGUAGE PROFICIENCY MEASURE
    POWERS, S
    JOHNSON, DM
    SLAUGHTER, HB
    CROWDER, C
    JONES, PB
    EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1985, 45 (04) : 959 - 963
  • [38] Reliability Of A Newly Developed Cycle Ergometer For Estimating Cardiorespiratory Fitness
    Sawada, Susumu S.
    Dimitroff, Serena A.
    Sano, Fumi
    Nakazawa, Yuki
    Zhai, Xiangyu
    Koriyama, Sakura
    Kurosawa, Sayaka
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 710 - 710
  • [39] Cycle Ergometer Tests in Children With Cystic Fibrosis: Reliability and Feasibility
    Kent, Lisa
    O'Neill, Brenda
    Davison, Gareth
    Nevill, Alan
    Murray, Joyce
    Reid, Alastair
    Elborn, J. Stuart
    Bradley, Judy M.
    PEDIATRIC PULMONOLOGY, 2012, 47 (12) : 1226 - 1234
  • [40] RELIABILITY, REPRODUCIBILITY AND VALIDITY OF THE INDIVIDUAL ANAEROBIC THRESHOLD
    MCLELLAN, TM
    JACOBS, I
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 67 (02): : 125 - 131