Reliability and Validity of the Velotron Racermate Cycle Ergometer to Measure Anaerobic Power

被引:26
|
作者
Astorino, T. A. [1 ]
Cottrell, T. [1 ]
机构
[1] Calif State Univ San Marcos, San Marcos, CA 92096 USA
关键词
Wingate test; PCr; fatigue index; supramaximal exercise; WINGATE; PERFORMANCE; SPORT;
D O I
10.1055/s-0031-1291219
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study assessed the reliability and validity of the Velotron Racermate (TM) cycle ergometer to assess anaerobic power. Men (9 cyclists and 13 recreationally-active) and women (17 recreationally-active and 1 cyclist) (age=24.7 +/- 4.2 yr) performed 2 Wingate tests on the Velotron or 3 Wingate tests (2 on the Velotron and 1 on the Monark Peak Bike) over a 7-14 day period. Peak power, mean power, minimum power, fatigue index, heart rate, and peak and minimum cadence were assessed. Results revealed significant test-retest reliability for mean power (r=0.90, p<0.01), minimum power (r=0.79, p<0.05) and peak power (r=0.70, p<0.05) with repeated bouts on the Velotron. Peak power was significantly higher (p<0.05) on the Velotron (9.95 +/- 1.39 W/kg) vs. the Monark (9.13 +/- 1.26 W/kg); however, mean power was higher (p<0.05) on the Monark (6.95 +/- 0.89 W/kg) vs. the Velotron (6.11 +/- 0.52 W/kg and 6.25 +/- 0.59 W/kg). Data reveal significant reliability for mean and peak power from the Velotron Racermate, yet multiple variables differ between the Velotron and the Monark mechanically-braked cycle ergometer.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [21] Interrater reliability of a customized submaximal cycle ergometer test
    M. A. Kantor
    S. Fretti
    C. Gubler
    M. Kramer
    R. W. Pettitt
    European Journal of Applied Physiology, 2023, 123 : 43 - 48
  • [22] Interrater reliability of a customized submaximal cycle ergometer test
    Kantor, M. A.
    Fretti, S.
    Gubler, C.
    Kramer, M.
    Pettitt, R. W.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2023, 123 (01) : 43 - 48
  • [23] INFLUENCE OF CYCLE ERGOMETER CHARACTERISTICS ON THE ADOLESCENTS ANAEROBIC ABILITIES TESTING
    DELGADO, A
    PERES, G
    ALLEMANDOU, A
    MONOD, H
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1993, 101 (02): : 145 - 148
  • [24] Power output reliability between Garmin® Vector meter and Lode Excalibur Sport® cycle ergometer
    Lanferdini F.J.
    Sperb C.H.
    da Rocha E.S.
    Baptista R.R.
    Vaz M.A.
    Lanferdini, Fábio Juner (fabiolanferdini@gmail.com), 1600, Springer (36): : 333 - 340
  • [25] A CYCLE ERGOMETER TEST OF MAXIMAL AEROBIC POWER
    MYLES, WS
    TOFT, RJ
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1982, 49 (01) : 121 - 129
  • [26] MEASUREMENT AND EXPLOITATION OF THE POWER DONE ON A CYCLE ERGOMETER
    FOUQUET, R
    BELLI, A
    JAY, J
    DUMAS, JC
    DENIS, C
    LOUIS, P
    BONNEFOY, R
    ROUGNY, R
    INNOVATION ET TECHNOLOGIE EN BIOLOGIE ET MEDECINE, 1993, 14 (06): : 709 - 717
  • [27] Validity of the revised Ekblom Bak cycle ergometer test in adults
    Bjorkman, Frida
    Ekblom-Bak, Elin
    Ekblom, Orjan
    Ekblom, Bjorn
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (09) : 1627 - 1638
  • [28] Validity of the revised Ekblom Bak cycle ergometer test in adults
    Frida Björkman
    Elin Ekblom-Bak
    Örjan Ekblom
    Björn Ekblom
    European Journal of Applied Physiology, 2016, 116 : 1627 - 1638
  • [29] The validity of cycling power recorded by the elite axiom ergometer
    Nesi, X
    Bosquet, L
    Carter, H
    Dekerle, J
    Pelayo, P
    JOURNAL OF HUMAN MOVEMENT STUDIES, 2006, 50 (02): : 91 - 101
  • [30] Reliability and Validity of a Novel Futsal Special Performance Test Designed to Measure Skills and Anaerobic Performance
    Farhani, Farid
    Rajabi, Hamid
    Negaresh, Raoof
    Ali, Ajmol
    Shalamzari, Sadegh Amani
    Baker, Julien S.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2019, 14 (08) : 1096 - 1102