Image-based 3D dosimetric studies with high dose rate intracavitary brachytherapy of cervical cancer

被引:0
作者
Chakravarty, N. [1 ]
Semwal, M. K. [1 ]
Trivedi, G. [1 ]
Suhag, V [1 ]
Jain, M. [1 ]
Sharma, N. [1 ]
Vashisth, R. S. [1 ]
机构
[1] Army Hosp R&R, Radiat Oncol Ctr, New Delhi 110010, India
关键词
bladder and rectum dose; cervical cancer; high dose rate; intracavitary brachytherapy; BLADDER; RECTUM; VOLUME; RADIOTHERAPY; RADIOGRAPHY;
D O I
10.1017/S1460396919000712
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To study 2D and 3D dosimetric values for bladder and rectum, and the influence of bladder volume on bladder dose in high dose rate (HDR) intracavitary brachytherapy (ICBT). The large patient data incorporated in this study would better represent the inherent variations in many parameters affecting dosimetry in HDR-ICBT. Material and Methods: We prospectively collected data for 103 consecutive cervical cancer patients (over 310 HDR fractions) undergoing CT-based HDR-ICBT at our centre. Correlation among bladder and rectum maximum volume doses and corresponding International Commission on Radiation Units and Measurement (ICRU) point doses were estimated and analysed. Impact of bladder volume on bladder maximum dose was assessed. Results: The ICRU point doses to bladder and rectum varied from the volumetric doses to these organs. Further, bladder volume poorly correlated with bladder maximum dose for volume variations encountered in the clinical practice at our centre. Findings: ICRU point doses to bladder and rectum are less likely to correlate with long-term toxicities to these organs. Further, in clinical practice where inter-fraction bladder volume does not vary widely there is no correlation between bladder volume and bladder dose.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [41] The adverse effect of treatment prolongation in cervical cancer by high-dose-rate intracavitary brachytherapy
    Chen, SW
    Liang, JA
    Yang, SN
    Ko, HL
    Lin, FJ
    RADIOTHERAPY AND ONCOLOGY, 2003, 67 (01) : 69 - 76
  • [42] Concurrent chemoradiotherapy using high-dose-rate intracavitary brachytherapy for uterine cervical cancer
    Toita, T
    Moromizato, H
    Ogawa, K
    Kakinohana, Y
    Maehama, T
    Kanazawa, K
    Murayama, S
    GYNECOLOGIC ONCOLOGY, 2005, 96 (03) : 665 - 670
  • [43] CT based three dimensional dose-volume evaluations for high-dose rate intracavitary brachytherapy for cervical cancer
    Naoya Murakami
    Takahiro Kasamatsu
    Akihisa Wakita
    Satoshi Nakamura
    Hiroyoki Okamoto
    Koji Inaba
    Madoka Morota
    Yoshinori Ito
    Minako Sumi
    Jun Itami
    BMC Cancer, 14
  • [44] Deep learning-based segmentation for high-dose-rate brachytherapy in cervical cancer using 3D Prompt-ResUNet
    Xue, Xian
    Sun, Lining
    Liang, Dazhu
    Zhu, Jingyang
    Liu, Lele
    Sun, Quanfu
    Liu, Hefeng
    Gao, Jianwei
    Fu, Xiaosha
    Ding, Jingjing
    Dai, Xiangkun
    Tao, Laiyuan
    Cheng, Jinsheng
    Li, Tengxiang
    Zhou, Fugen
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (19)
  • [45] High versus low-dose rate brachytherapy for cervical cancer
    Patankar, Sonali S.
    Tergas, Ana I.
    Deutsch, Israel
    Burke, William M.
    Hou, June Y.
    Ananth, Cande V.
    Huang, Yongmei
    Neugut, Alfred I.
    Hershman, Dawn L.
    Wright, Jason D.
    GYNECOLOGIC ONCOLOGY, 2015, 136 (03) : 534 - 541
  • [46] Three-dimensional image-guided combined intracavitary and interstitial high-dose-rate brachytherapy in cervical cancer: A systematic review
    Li, Fei
    Lu, Shuangchen
    Zhao, Hongfu
    Mu, Xin
    Mao, Zhuang
    BRACHYTHERAPY, 2021, 20 (01) : 85 - 94
  • [47] The use of trans-applicator intracavitary ultrasonography in brachytherapy for cervical cancer: phantom study of a novel approach to 3D image-guided brachytherapy
    Tamaki, Tomoaki
    Miyaura, Kazunori
    Murakami, Toshihiro
    Kumazaki, Yu
    Suzuki, Yoshiyuki
    Nakano, Takashi
    Kato, Shingo
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (02) : 151 - 157
  • [48] Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high-dose-rate brachytherapy for breast cancer
    Kim, Yongbok
    Trombetta, Mark G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 76 - 89
  • [49] A dosimetric comparison of Volumetric Modulated Arc Therapy (VMAT) and High Dose Rate (HDR) brachytherapy in localized cervical cancer radiotherapy
    Wali, Lila
    Helal, Azza
    Darwesh, Reem
    Attar, Mohammed
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (03) : 473 - 483
  • [50] Preliminary analysis of early and late radiation responses in 3D image-guided brachytherapy for cervical cancer
    Andreyeva, Olga B.
    Adylkhanov, Tasbolat A.
    Kaidarova, Dilyara R.
    Isayev, Isa G.
    Kurmangaliyev, Tolegen S.
    Khismetova, Zaituna A.
    Glushkova, Natalya E.
    RUSSIAN OPEN MEDICAL JOURNAL, 2022, 11 (02)