Rodent functional and anatomical imaging of pain

被引:60
|
作者
Thompson, Scott J. [1 ,4 ]
Bushnell, M. Catherine [1 ,2 ,3 ,4 ]
机构
[1] McGill Univ, Alan Edwards Ctr Res Pain, Montreal, PQ H3A 2T5, Canada
[2] McGill Univ, Fac Dent, Montreal, PQ H3A 2T5, Canada
[3] McGill Univ, Dept Anesthesiol, Montreal, PQ H3A 2T5, Canada
[4] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ H3A 2T5, Canada
关键词
Pain; Imaging; MRI; PET; Preclinical; Rodent; MAGNETIC-RESONANCE SPECTROSCOPY; SPINAL-CORD-INJURY; CHRONIC BACK-PAIN; FOREPAW STIMULATION; ANESTHETIZED RAT; JOINT MOBILIZATION; BRAIN ACTIVATION; ALPHA-CHLORALOSE; NEUROPATHIC PAIN; BOLD-FMRI;
D O I
10.1016/j.neulet.2012.03.015
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Human brain imaging has provided much information about pain processing and pain modulation, but brain imaging in rodents can provide information not attainable in human studies. First, the short lifespan of rats and mice, as well as the ability to have homogenous genetics and environments, allows for longitudinal studies of the effects of chronic pain on the brain. Second, brain imaging in animals allows for the testing of central actions of novel pharmacological and nonpharmacological analgesics before they can be tested in humans. The two most commonly used brain imaging methods in rodents are magnetic resonance imaging (MRI) and positron emission tomography (PET). MRI provides better spatial and temporal resolution than PET, but PET allows for the imaging of neurotransmitters and non-neuronal cells, such as astrocytes, in addition to functional imaging. One problem with rodent brain imaging involves methods for keeping the subject still in the scanner. Both anesthetic agents and restraint techniques have potential confounds. Some PET methods allow for tracer uptake before the animal is anesthetized, but imaging a moving animal also has potential confounds. Despite the challenges associated with the various techniques, the 31 studies using either functional MRI or PET to image pain processing in rodents have yielded surprisingly consistent results, with brain regions commonly activated in human pain imaging studies (somatosensory cortex, cingulate cortex, thalamus) also being activated in the majority of these studies. Pharmacological imaging in rodents shows overlapping activation patterns with pain and opiate analgesics, similar to what is found in humans. Despite the many structural imaging studies in human chronic pain patients, only one study has been performed in rodents, but that study confirmed human findings of decreased cortical thickness associated with chronic pain. Future directions in rodent pain imaging include miniaturized PET for the freely moving animal, as well as new MRI techniques that enable ongoing chronic pain imaging. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 50 条
  • [41] Imaging of orofacial pain
    Whyte, Andy
    Matias, Marie Anne Teresa J.
    JOURNAL OF ORAL PATHOLOGY & MEDICINE, 2020, 49 (06) : 490 - 498
  • [42] Imaging as a Pain Biomarker
    Kashanian, Alon
    Tsolaki, Evangelia
    Caruso, James
    Bari, Ausaf
    Pouratian, Nader
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2022, 33 (03) : 345 - 350
  • [43] Imaging of Neuropathic Pain
    Bedewi, Mohamed A.
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2022, 12 (01) : 19 - 23
  • [44] Editorial: Morphological and functional imaging: a combined approach
    Albano, Domenico
    Besutti, Giulia
    FRONTIERS IN MEDICINE, 2023, 10
  • [45] Completing the Pain Circuit: Recent Advances in Imaging Pain and Inflammation beyond the Central Nervous System
    Linnman, Clas
    Borsook, David
    RAMBAM MAIMONIDES MEDICAL JOURNAL, 2013, 4 (04):
  • [46] Introduction to rodent cardiac imaging
    Johnson, Kennita
    ILAR JOURNAL, 2008, 49 (01) : 27 - 34
  • [47] Feasibility of Small Animal Anatomical and Functional Imaging with Neutrons: A Monte Carlo Simulation Study
    Medich, David C.
    Currier, Blake H.
    Karellas, Andrew
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2480 - 2488
  • [48] Simultaneous positron emission tomography and ultrafast ultrasound for hybrid molecular, anatomical and functional imaging
    Provost, Jean
    Garofalakis, Anikitos
    Sourdon, Joevin
    Bouda, Damien
    Berthon, Beatrice
    Viel, Thomas
    Perez-Liva, Mailyn
    Lussey-Lepoutre, Charlotte
    Favier, Judith
    Correia, Mafalda
    Pernot, Mathieu
    Chiche, Johanna
    Pouyssegur, Jacques
    Tanter, Mickael
    Tavitian, Bertrand
    NATURE BIOMEDICAL ENGINEERING, 2018, 2 (02): : 85 - 94
  • [49] Systematic Review: Anesthetic Protocols and Management as Confounders in Rodent Blood Oxygen Level Dependent Functional Magnetic Resonance Imaging (BOLD fMRI)-Part B: Effects of Anesthetic Agents, Doses and Timing
    Steiner, Aline R.
    Rousseau-Blass, Frederik
    Schroeter, Aileen
    Hartnack, Sonja
    Bettschart-Wolfensberger, Regula
    ANIMALS, 2021, 11 (01): : 1 - 34
  • [50] Structural imaging studies of patients with chronic pain: an anatomical likelihood estimate meta-analysis
    Henn, Alina T.
    Larsen, Bart
    Frahm, Lennart
    Xu, Anna
    Adebimpe, Azeez
    Scott, J. Cobb
    Linguiti, Sophia
    Sharma, Vaishnavi
    Basbaum, Allan, I
    Corder, Gregory
    Dworkin, Robert H.
    Edwards, Robert R.
    Woolf, Clifford J.
    Habel, Ute
    Eickhoff, Simon B.
    Eickhoff, Claudia R.
    Wagels, Lisa
    Satterthwaite, Theodore D.
    PAIN, 2023, 164 (01) : E10 - E24