Polishing Methods' Influence on Color Stability and Roughness of 2 Provisional Prosthodontic Materials

被引:27
作者
Soares, Irenaldo Andre [1 ]
Batista da Silva Leite, Priscilla Kelly [1 ]
Farias, Ohana Rodrigues [1 ]
Lemos, George Azevedo [2 ]
Dantas Batista, Andre Ulisses [3 ]
Montenegro, Robinsom Viegas [3 ]
机构
[1] Fed Univ Paraiba UFPB, Joao Pessoa, Paraiba, Brazil
[2] UNIFACISA, Campina Grande, Brazil
[3] Fed Univ Paraiba UFPB, Restorat Dent Dept, Joao Pessoa, Paraiba, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2019年 / 28卷 / 05期
关键词
Acrylic resins; dental polishing; food coloring agents; provisional dental restoration; SURFACE-ROUGHNESS; STAINABILITY; COMPOSITE; CROWN;
D O I
10.1111/jopr.13062
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the roughness and color change of a conventional acrylic resin and a bis-acryl resin, submitted to different types of polishing and exposed to a staining solution. Materials and Methods One hundred specimens were manufactured from an autopolymerizing conventional acrylic resin (Duralay, shade 66) (n = 50) and a bis-acryl resin (Protemp 4, shade A3) (n = 50) according to the manufacturers' instructions. Specimens were subdivided into 10 groups (n = 10), according to the type of resin and polishing method, including no-polishing (control groups for acrylic resin [tungsten bur finishing] and bis-acryl resin [cotton and alcohol]), Enhance System, Edenta kit, Labordental kit, and sandpaper. The specimens were immersed in a staining solution (coffee at 60 degrees C) for 7 days. Surface roughness was evaluated before the first immersion (baseline - Ra1) and after 7 days (Ra2). The color change ( increment E) was determined after 24 hours ( increment E1) and 7 days ( increment E2), by CIE L* a* b* scale. Data were statistically analyzed with 3-way ANOVA for repeated measures test and Tukey test (alpha = 0.05). Results According to 3-way ANOVA test, material, polishing techniques, and polishing*material factors exhibited statistically significant influence (p < 0.0001) on the roughness, and, for color change, material, polishing techniques, time, polishing*material, and material*time factors were statistically significant (p < 0.0001). The polishing techniques successfully reduced the surface roughness of acrylic resin groups, when compared to control (p < 0.001), but for bis-acryl resin, results were not different from the control group (Enhance: p = 0.954, Edenta: p = 0.866, sandpaper: p = 0.366, Labordental: p = 0.945). Surface roughness was not affected by the immersion in staining solution for 7 days. Color change of acrylic resin groups after 24 hours and 7 days of immersion exhibited a clinically acceptable value (Delta E < 3.7) with the exception of the Enhance group, and all bis-acryl resin groups exhibited a clinically unacceptable color change value (Delta E > 3.7) independent of polishing technique and time interval ( increment E1 and increment E2). Conclusions Roughness of both materials was similar when the polishing techniques studied were performed, although Ra values were superior to the clinically acceptable values (0.20 mu m), and were not affected by the immersion protocol studied; however, when esthetics are critical, the selection of material type is more important than the surface treatment technique used, and bis-acryl resin was more susceptible to clinically unacceptable color change after immersion in a staining solution.
引用
收藏
页码:564 / 571
页数:8
相关论文
共 31 条
[11]  
Haselton Debra R, 2004, J Prosthodont, V13, P227
[12]   Color stability of provisional crown and fixed partial denture resins [J].
Haselton, DR ;
Diaz-Arnold, AM ;
Dawson, DV .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01) :70-75
[13]  
Hemming Michael, 2015, J Contemp Dent Pract, V16, P933
[14]  
Jefferies Steven R, 2007, Dent Clin North Am, V51, P379, DOI 10.1016/j.cden.2006.12.002
[15]   Effects of chairside polishing and brushing on surface roughness of acrylic denture base resins [J].
Kim, Seung-Kyun ;
Park, Ju-Mi ;
Lee, Min-Ho ;
Jung, Jae-Youn ;
Li, Shipu ;
Wang, Xinyu .
JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2009, 24 (01) :100-105
[16]  
Köroglu A, 2016, J PROSTHET DENT, V115, P447, DOI 10.1016/j.prosdent.2015.10.005
[17]   Variation in surface texture measurements [J].
Macdonald, W ;
Campbell, P ;
Fisher, J ;
Wennerberg, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 70B (02) :262-269
[18]   Effect of different polishing methods on surface roughness of provisional prosthetic materials [J].
Maia Tupinamba, Ivian Verena ;
Correa Giampa, Priscila Couy ;
Rios Rocha, Isadora Almeida ;
Castor Xisto Lima, Emilena Maria .
JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02) :96-101
[19]  
Mickeviciute Egle, 2016, Stomatologija, V18, P66
[20]   Management of Provisional Restorations' Deficiencies: A Literature Review [J].
Patras, Michael ;
Naka, Olga ;
Doukoudakis, Spyridon ;
Pissiotis, Argiris .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2012, 24 (01) :26-38