Accuracy of automated patient positioning in CT using a 3D camera for body contour detection

被引:41
|
作者
Booij, Ronald [1 ]
Budde, Ricardo P. J. [1 ]
Dijkshoorn, Marcel L. [1 ]
van Straten, Marcel [1 ]
机构
[1] Erasmus MC, Dept Radiol & Nucl Med, POB 2240, NL-3000 CA Rotterdam, Netherlands
关键词
Tomography; x-ray computed; Health physics; Radiation dosage; Diagnostic imaging; IMAGE NOISE; COMPUTED-TOMOGRAPHY; IMPACT; MDCT;
D O I
10.1007/s00330-018-5745-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo assess the accuracy of a 3D camera for body contour detection and patient positioning in CT compared to routine manual positioning by radiographers.Methods and materialsFour hundred twenty-three patients that underwent CT of the head, thorax, and/or abdomen on a scanner with manual table height selection and 254 patients on a scanner with table height suggestion by a 3D camera were retrospectively included. Within the camera group, table height suggestion was based on infrared body contour detection and fitting of a scalable patient model to the 3D data. Proper positioning was defined as the ideal table height at which the scanner isocenter coincides with the patient's isocenter. Patient isocenter was computed by automatic skin contour extraction in each axial image and averaged over all images. Table heights suggested by the camera and selected by the radiographer were compared with the ideal height.ResultsMedian (interquartile range) absolute table height deviation in millimeter was 12.0 (21.6) for abdomen, 12.2 (12.0) for head, 13.4 (17.6) for thorax-abdomen, and 14.7 (17.3) for thorax CT scans positioned by radiographers. The deviation was significantly less (p<0.01) for the 3D camera at 6.3 (6.9) for abdomen, 9.5 (6.8) for head, 6.0 (6.1) for thorax-abdomen, and 5.4 (6.4)mm for thorax.ConclusionA 3D camera for body contour detection allows for accurate patient positioning, thereby outperforming manual positioning done by radiographers, resulting in significantly smaller deviations from the ideal table height. However, radiographers remain indispensable when the system fails or in challenging cases.Key Points center dot A 3D camera for body contour detection allows for accurate patient positioning.center dot A 3D camera outperformed radiographers in patient positioning in CT.center dot Deviation from ideal table height was more extreme for patients positioned by radiographers for all body parts.
引用
收藏
页码:2079 / 2088
页数:10
相关论文
共 50 条
  • [21] Anatomic Positioning System: Accuracy of Localization of Mock Blast Fragments on CT in 3D
    Shogan, P.
    Fischer, T.
    Long, J.
    Frew, M.
    Bunger, R.
    Folio, L.
    Provenzale, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [22] Onmidirectional camera calibration and 3D reconstruction by contour matching
    Hwang, Yongho
    Lee, Jaeman
    Hong, Hyunki
    ADVANCES IN VISUAL COMPUTING, PT 1, 2006, 4291 : 881 - +
  • [23] A robust 3D morphological algorithm for automatic skin contour detection on CT images
    Kim, JK
    Yin, F
    Zhao, Y
    Kim, JH
    MEDICAL PHYSICS, 2003, 30 (06) : 1459 - 1459
  • [24] Accuracy of 3D Camera Based Virtual Keyboard
    Hagara, Miroslav
    Pucik, Jozef
    2014 24TH INTERNATIONAL CONFERENCE RADIOELEKTRONIKA (RADIOELEKTRONIKA 2014), 2014,
  • [25] Monitoring of Patient Blanket Coverage using 3D Camera Data
    Vaughn, Julie
    Milosevic, Mladen
    Parvaneh, Saman
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 864 - 867
  • [26] PRECISE 3D POSITIONING OF A ROBOTIC ARM USING A SINGLE CAMERA AND A FLAT MIRROR
    Kulpate, Chaiyapol
    Paranjape, Raman
    Mehrandezh, Mehran
    INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2008, 2 (03) : 205 - 232
  • [27] REAL-TIME OBJECT DETECTION, TRACKING, AND 3D POSITIONING IN A MULTIPLE CAMERA SETUP
    Lee, Y. J.
    Yilmaz, A.
    ISA13 - THE ISPRS WORKSHOP ON IMAGE SEQUENCE ANALYSIS 2013, 2013, II-3/W2 : 31 - 35
  • [28] Navidget for 3D interaction: Camera positioning and further uses
    Hachet, Martin
    Decle, Fabrice
    Knoedel, Sebastian
    Guitton, Pascal
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER STUDIES, 2009, 67 (03) : 225 - 236
  • [29] Application of a precision-enhancing measure in 3D rigid-body positioning using camera-space manipulation
    GonzalezGalvan, EJ
    Skaar, SB
    Korde, UA
    Chen, WZ
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1997, 16 (02): : 240 - 257
  • [30] Application of a precision-enhancing measure in 3D rigid-body positioning using camera-space manipulation
    Univ of Notre Dame, Notre Dame, United States
    Int J Rob Res, 2 (240-257):