摘要
The new constructing railway Haerbin-Dalian Dedicate Line runs through the typical seasonal frozen region. For the purpose of estimating the quality of subgrade construction, a field test was played. Placed the monitoring instrument and measure the soil temperature, settlement and soil pressure etc.. The monitoring data shows that the change of soil temperature is less than the environment temperature. The maximum frost depth is 1.66m. In this depth, the fine-grained soil with high frost-heave characteristic should not be as the subgrade. The effective measure to prevent the rain percolated through the subgrade is important. And the filling of subgrade should be constructed strictly according to the maximal degree of compaction and keep the best water content. The settlement of subgrade is less than 15mm, the water content is also less than the prime frost-heave water content and the frost-heave force is very small. Thus, the construction technique subgrade is feasible.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 4 条
[1]  
[刘永智 Liu Yongzhi], 2002, [冰川冻土, Journal of Glaciology and Geocryology], V24, P10
[2]  
Meng F., 2001, J GLACIOL GEOCRYOL, V23, P307, DOI [10.3969/j.issn.1000-0240.2001.03.016, DOI 10.3969/J.ISSN.1000-0240.2001.03.016]
[3]  
Zhang Jianming, 2004, J GLACIOLOGY GEOCR S, V24, P155
[4]  
Zhong Wei, 2007, SUBGRADE ENG, P59