In vitro and in vivo evaluation of a dextran-graft-polybutylmethacrylate copolymer coated on CoCr metallic stent

被引:4
作者
Delattre, Cecilia [1 ]
Velazquez, Diego [1 ]
Roques, Caroline [1 ,2 ]
Pavon-Djavid, Graciela [1 ,2 ]
Veronique, Ollvier [1 ,2 ]
Lokajczyk, Anna [3 ,4 ]
Avramoglou, Thierry [1 ,2 ]
Gueguen, Virginie [1 ,2 ]
Louedec, Liliane [1 ,2 ]
Caligiuri, Giuseppina [1 ,2 ]
Jandrot-Perrus, Martine [1 ,2 ]
Boisson-Vidal, Catherine [3 ,4 ]
Letourneur, Didier [1 ,2 ]
Meddahi-Pelle, Anne [1 ,2 ]
机构
[1] Hop Bichat Claude Bernard, UMR S1148, INSERM, Lab Vasc Translat Sci, Paris, France
[2] Univ Paris 13, Sorbonne Paris Cite, Paris, France
[3] INSERM, UMR S1140, Paris, France
[4] Univ Paris 05, Sorbonne Paris Cite, Paris, France
关键词
Animal model; Biocompatibility; Dextran; Haemocompatibility; In vitro; Stent; DRUG-ELUTING STENTS; STAPHYLOCOCCUS-AUREUS ADHESION; ENDOTHELIAL PROGENITOR CELLS; CORONARY STENTS; RE-ENDOTHELIALIZATION; RELEASE KINETICS; BARE METAL; RESTENOSIS; IMPLANTATION; THROMBOSIS;
D O I
10.15171/bi.2019.04
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: The major complications of stent implantation are restenosis and late stent thrombosis. PBMA polymers are used for stent coating because of their mechanical properties. We previously synthesized and characterized Dextrangraft-polybutylmethacrylate copolymer (Dex-PBMA) as a potential stent coating. In this study, we evaluated the haemocompatibility and biocompatibility properties of Dex-PBMA in vitro and in vivo. Methods: Here, we investigated: (1) the effectiveness of polymer coating under physiological conditions and its ability to release Tacrolimus (R), (2) the capacity of Dex-PBMA to inhibit Staphylococcus aureus adhesion, (3) the thrombin generation and the human platelet adhesion in static and dynamic conditions, (4) the biocompatibility properties in vitro on human endothelial colony forming cells (ECFC) and on mesenchymal stem cells (MSC) and in vivo in rat models, and (5) we implanted Dex-PBMA and Dex-PBMA(TAC) coated stents in neointimal hyperplasia restenosis rabbit model. Results: Dex-PBMA coating efficiently prevented bacterial adhesion and release Tacrolimus (R). Dex-PBMA exhibit haemocompatibility properties under flow and ECFC and MSC compatibility. In vivo, no pathological foreign body reaction was observed neither after intramuscular nor intravascular aortic implantation. After Dex-PBMA and Dex-PBMA(TAC) coated stents 30 days implantation in a restenosis rabbit model, an endothelial cell coverage was observed and the lumen patency was preserved. Conclusion: Based on our findings, Dex-PBMA exhibited vascular compatibility and can potentially be used as a coating for metallic coronary stents.
引用
收藏
页码:25 / 36
页数:12
相关论文
共 60 条
  • [1] New Drug-Eluting Stents An Overview on Biodegradable and Polymer-Free Next-Generation Stent Systems
    Abizaid, Alexandre
    Costa, J. Ribamar, Jr.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 384 - 393
  • [2] Osteoblast functions on functionalized PMMA-based polymers exhibiting Staphylococcus aureus adhesion inhibition
    Anagnostou, F
    Debet, A
    Pavon-Djavid, G
    Goudaby, Z
    Hélary, G
    Migonney, V
    [J]. BIOMATERIALS, 2006, 27 (21) : 3912 - 3919
  • [3] Foreign body reaction to biomaterials
    Anderson, James M.
    Rodriguez, Analiz
    Chang, David T.
    [J]. SEMINARS IN IMMUNOLOGY, 2008, 20 (02) : 86 - 100
  • [4] Clinical and angiographic outcomes following elective implantation of the Carbostent in patients at high risk of restenosis and target vessel failure
    Antoniucci, D
    Valenti, R
    Migliorini, A
    Moschi, G
    Trapani, M
    Bolognese, L
    Santoro, GM
    Cerisano, G
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (04) : 420 - 426
  • [5] Baier R E, 1969, J Biomed Mater Res, V3, P191, DOI 10.1002/jbm.820030115
  • [6] Bartorelli Antonio L, 2003, J Interv Cardiol, V16, P499, DOI 10.1046/j.1540-8183.2003.01050.x
  • [7] Scanning electron microscopic assessment of coating irregularities and their precursors in unexpanded durable polymer-based drug-eluting stents
    Basalus, Mounir W. Z.
    Tandjung, Kenneth
    van Westen, Thea
    Sen, Hanim
    van der Jagt, Pasquelle K. N.
    Grijpma, Dirk W.
    van Apeldoorn, Aart A.
    von Birgelen, Clemens
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (04) : 644 - 653
  • [8] Infections of Intravascular Bare Metal Stents: A Case Report and Review of Literature
    Bosman, W. M. P. F.
    van der Burg, B. L. S. Borger
    Schuttevaer, H. M.
    Thoma, S.
    Joosten, P. Ph. Hedeman
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 47 (01) : 87 - 99
  • [9] Absorb bioresorbable vascular scaffold: What have we learned after 5 years of clinical experience?
    Caiazzo, Gianluca
    Kilic, Ismail Dogu
    Fabris, Enrico
    Serdoz, Roberta
    Mattesini, Alessio
    Foin, Nicolas
    De Rosa, Salvatore
    Indolfi, Ciro
    Di Mario, Carlo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 : 129 - 136
  • [10] Polyethylene and metal wear particles: characteristics and biological effects
    Catelas, Isabelle
    Wimmer, Markus A.
    Utzschneider, Sandra
    [J]. SEMINARS IN IMMUNOPATHOLOGY, 2011, 33 (03) : 257 - 271