A new plan quality index for nasopharyngeal cancer SIB IMRT

被引:11
作者
Jin, X. [1 ]
Yi, J. [1 ]
Zhou, Y. [1 ]
Yan, H. [1 ]
Han, C. [1 ]
Xie, C. [1 ]
机构
[1] Wenzhou Med Coll, Affiliated Hosp 1, Radiotherapy & Chemotherapy Dept, Wenzhou 325000, Peoples R China
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2014年 / 30卷 / 01期
关键词
Nasopharyngeal cancer; SIB-IMRT; Plan quality index; Radiobiological index; INTENSITY-MODULATED RADIOTHERAPY; DOSE-VOLUME HISTOGRAMS; RADIATION-THERAPY; NORMAL TISSUE; CARCINOMA; TOLERANCE; TOOL;
D O I
10.1016/j.ejmp.2013.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new plan quality index integrating dosimetric and radiobiological indices was proposed to facilitate the evaluation and comparison of simultaneous integrated boost (SIB) intensity modulated radiotherapy (IMRT) plans for nasopharyngeal cancer (NPC) patients. Ten NPC patients treated by SIB-IMRT were enrolled in the study. Custom software was developed to read dose volume histogram (DVH) curves from the treatment planning system (TPS). A plan filtering matrix was introduced to filter plans that fail to satisfy treatment protocol. Target plan quality indices and organ at risk (OAR) plan quality indices were calculated for qualified plans. A unique composite plan quality index (CPQI) was proposed based on the relative weight of these indices to evaluate and compare competing plans. Plan ranking results were compared with detailed statistical analysis, radiation oncology quality system (ROQS) scoring results and physician's evaluation results to verify the accuracy of this new plan quality index. The average CPQI values for plans with OAR priority of low, normal, high, and PTV only were 0.22 +/- 0.08, 0.49 +/- 0.077, 0.71 +/- 0.062, and -0.21 +/- 0.16, respectively. There were significant differences among these plan quality indices (One-way ANOVA test, p < 0.01). This was consistent with statistical analysis, ROQS results and physician's ranking results in which 90% OAR high plans were selected. Plan filtering matrix was able to speed up the plan evaluation process. The new matrix plan quality index CPQI showed good consistence with physician ranking results. It is a promising index for NPC SIB-IMRT plan evaluation. (C) 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 23 条
[1]   DOSE VOLUME HISTOGRAM ANALYSIS OF LIVER RADIATION TOLERANCE [J].
AUSTINSEYMOUR, MM ;
CHEN, GTY ;
CASTRO, JR ;
SAUNDERS, WM ;
PITLUCK, S ;
WOODRUFF, KH ;
KESSLER, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (01) :31-35
[2]   FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION [J].
BURMAN, C ;
KUTCHER, GJ ;
EMAMI, B ;
GOITEIN, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :123-135
[3]   Treatment plan evaluation using dose-volume histogram (DVH) and spatial dose-volume histogram (zDVH) [J].
Cheng, CW ;
Das, IJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05) :1143-1150
[4]  
DRZYMALA RE, 1987, MED PHYS, V14, P460
[5]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122
[6]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[7]   Three-dimensional conformal versus intensity-modulated radiotherapy dose planning in stereotactic radiotherapy: application of standard quality parameters for plan evaluation [J].
Grzadziel, Aleksandra ;
Grosu, Anca-Ligia ;
Kneschaurek, Peter .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04) :S87-S94
[8]   TECHNICAL AND DOSIMETRIC CONSIDERATIONS IN MULTI-ISOCENTER INTENSITY MODULATED RADIOTHERAPY FOR NASOPHARYNGEAL CARCINOMA WITH SMALL MULTILEAF COLLIMATOR [J].
Jin Xiance ;
Wu Shixiu ;
Yu Jianyi ;
Yi Jinling .
MEDICAL DOSIMETRY, 2009, 34 (01) :9-15
[9]   Treatment of nasopharyngeal carcinoma with intensity-modulated radiotherapy: The Hong Kong experience [J].
Kam, MKM ;
Teo, PML ;
Chau, RMC ;
Cheung, KY ;
Choi, PHK ;
Kwan, WH ;
Leung, SF ;
Zee, B ;
Chan, ATC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05) :1440-1450
[10]   Intensity-modulated radiotherapy in the treatment of nasopharyngeal carcinoma: An update of the UCSF experience [J].
Lee, N ;
Xia, P ;
Quivey, JM ;
Sultanem, K ;
Poon, I ;
Akazawa, C ;
Akazawa, PM ;
Weinberg, V ;
Fu, KK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (01) :12-22