This study compared the imaging performance of a photostimulable phosphor system with E speed film for dental radiography. The response of each imaging system was measured as a function of radiation exposure. Measurements were also made of imaging performance in terms of the limiting spatial resolution and low contrast detectability. Photostimulable phosphors had a wider dynamic range in comparison with film. The limiting spatial resolution of the photostimulable phosphor was approximately 6.5 lp/mm and independent of image magnification. For film, the limiting spatial resolution was in the range 11 to 20 lp/mm depending on image magnification. At the same radiation exposure, low contrast detectability of the photostimulable phosphor was superior to that of film. Major benefits of photostimulable phosphor systems include the elimination of chemical processing and an improved low contrast detectability performance.
引用
收藏
页码:725 / 731
页数:7
相关论文
共 25 条
  • [1] BALTER S, 1988, ACTA RADIOL, V29, P257
  • [2] Borg E, 1996, ENDOD DENT TRAUMATOL, V12, P20
  • [3] BASIC IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHIC SYSTEM WITH PHOTOSTIMULABLE PHOSPHORS
    FUJITA, H
    UEDA, K
    MORISHITA, J
    FUJIKAWA, T
    OHTSUKA, A
    SAI, T
    [J]. MEDICAL PHYSICS, 1989, 16 (01) : 52 - 59
  • [4] GIGER ME, 1994, COMPUTER AIDED DIAGN, P287
  • [5] TECHNICAL ASPECTS OF A DEDICATED QUALITY-CONTROL SYSTEM FOR DENTAL RADIOLOGY
    GOULD, RG
    GRATT, BM
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (04): : 437 - 444
  • [6] A SET OF X-RAY TEST OBJECTS FOR QUALITY-CONTROL IN TELEVISION FLUOROSCOPY
    HAY, GA
    CLARKE, OF
    COLEMAN, NJ
    COWEN, AR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (688) : 335 - 344
  • [7] IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM
    HILLEN, W
    SCHIEBEL, U
    ZAENGEL, T
    [J]. MEDICAL PHYSICS, 1987, 14 (05) : 744 - 751
  • [8] A cost-analysis of computed radiography and picture archiving and communication systems in portable radiography
    Huda, W
    Honeyman, JC
    Frost, MM
    Staab, EV
    [J]. JOURNAL OF DIGITAL IMAGING, 1996, 9 (01) : 39 - 44
  • [9] ASSESSING DENTAL PRACTICE QUALITY BY EVALUATING RADIOLOGY ITEMS
    HUNT, RJ
    FANN, SJ
    KANTOR, ML
    MORRIS, AL
    [J]. JOURNAL OF PUBLIC HEALTH DENTISTRY, 1992, 52 (05) : 264 - 268
  • [10] INTRAORAL COMPUTED RADIOGRAPHY USING THE FUJI COMPUTED RADIOGRAPHY IMAGING PLATE - CORRELATION BETWEEN IMAGE QUALITY AND READING CONDITION
    KASHIMA, I
    SAKURAI, T
    MATSUKI, T
    NAKAMURA, K
    AOKI, H
    ISHII, M
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (02): : 239 - 246