Analysis of diluted sea-water at the ng L-1 level using an ICP-MS with an octopole reaction cell

被引:129
作者
Leonhard, P
Pepelnik, R
Prange, A [1 ]
Yamada, N
Yamada, T
机构
[1] GKSS Forschungszentrum Geesthacht GmbH, Inst Coastal Res Phys & Chem Anal, Geesthacht, Germany
[2] Agilent Technol, Tokyo, Japan
关键词
D O I
10.1039/b110180n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ICP-MS with an octopole reaction/collision cell was used for the multi-element determination of trace elements in sea-water. The use of a reaction or collision gas, respectively, reduces serious spectral interferences from matrix elements such as ArCl+ or ArNa+. On introducing He or H-2 to the cell, detection limits of 0.3 ng L-1 for U to 20 ng L-1 for Fe and As were determined in 10-fold diluted sea-water. The trace elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Mo, Cd, Pb and U were determined in diluted sea-water samples (certified reference material: NASS-5, SLEW-3) with a trueness of +/- 20% to the certified values. For most of the elements an accuracy of better than 19% was achieved with no sample pre-treatment other than simple dilution.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 45 条
[1]   Determination of trace elements in sea-water by inductively coupled plasma mass spectrometry after preconcentration by formation of water-soluble complexes and their adsorption on C18-bonded silica gel [J].
Akatsuka, K ;
Suzuki, T ;
Nobuyama, N ;
Hoshi, S ;
Haraguchi, K ;
Nakagawa, L ;
Ogata, T ;
Kato, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (04) :271-275
[2]   A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part 1. The rf-field energy contribution in thermodynamics of ion-molecule reactions [J].
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1133-1142
[3]   Determination of trace metals in seawater by inductively coupled plasma mass spectrometry after off-line dithiocarbamate solvent extraction [J].
Batterham, GJ ;
Munksgaard, NC ;
Parry, DL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1277-1280
[4]   Mass spectrometric and theoretical investigations into the formation of argon molecular ions in plasma mass spectrometry [J].
Becker, JS ;
Seifert, G ;
Saprykin, AI ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :643-648
[5]  
*DIN EV, 1994, 32645 DIN EV
[6]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408
[7]   Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cell [J].
Du, ZY ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :383-388
[8]   Selective removal of plasma matrix ions in plasma source mass spectrometry [J].
Eiden, GC ;
Barinaga, CJ ;
Koppenaal, DW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) :317-322
[9]   Application of a hexapole collision and reaction cell in ICP-MS Part II: Analytical figures of merit and first applications [J].
Feldmann, I ;
Jakubowski, N ;
Thomas, C ;
Stuewer, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :422-428
[10]   Application of a hexapole collision and reaction cell in ICP-MS Part I: Instrumental aspects and operational optimization [J].
Feldmann, I ;
Jakubowski, N ;
Stuewer, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :415-421