Investigation of photon and proton overlapping fields in PRESAGE® dosimeters

被引:1
作者
Carroll, M. [1 ,2 ]
Ibbott, G. [1 ]
Grant, R. [1 ]
Gillin, M. [1 ]
Adamovics, J. [3 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
[3] Heuris Pharma LLC, Skillman, NJ 08558 USA
来源
7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2013年 / 444卷
关键词
POLYMER GEL DOSIMETRY; RADIOLOGICAL PROPERTIES; IRRADIATION;
D O I
10.1088/1742-6596/444/1/012059
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To evaluate the effects of overlapping dose volumes for varying field arrangements in PRESAGE (R), several sequential beam irradiations were delivered each to formulations intended for, and irradiated with, proton beams as well as photon beams. The dosimeters were irradiated within timespans consistent of overlapping fields in clinical treatment plans. Dose profiles taken along the beam direction indicated slight over-responses in higher dose regions relative to similar irradiations given in a single fraction. These results will aid future measurements of overlapping field treatment plans delivered to PRESAGE (R) for treatment verification of proton and photon 3D dosimetry.
引用
收藏
页数:3
相关论文
共 10 条
[1]  
Adamovics J., 2006, Journal of Physics: Conference Series, V56, P176, DOI 10.1088/1742-6596/56/1/021
[2]  
Adamovics J., 2006, Journal of Physics: Conference Series, V56, P172, DOI 10.1088/1742-6596/56/1/020
[3]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[4]   Radiological properties of the PRESAGE and PAGAT polymer dosimeters [J].
Brown, S. ;
Venning, A. ;
De Deene, Y. ;
Vial, P. ;
Oliver, L. ;
Adamovics, J. ;
Baldock, C. .
APPLIED RADIATION AND ISOTOPES, 2008, 66 (12) :1970-1974
[5]   Investigation of radiological properties and water equivalency of PRESAGE® dosimeters [J].
Gorjiara, Tina ;
Hill, Robin ;
Kuncic, Zdenka ;
Adamovics, John ;
Bosi, Stephen ;
Kim, Jung-Ha ;
Baldock, Clive .
MEDICAL PHYSICS, 2011, 38 (04) :2265-2274
[6]   A study of a normoxic polymer gel dosimeter comprising methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride (MAGAT) [J].
Hurley, C ;
Venning, A ;
Baldock, C .
APPLIED RADIATION AND ISOTOPES, 2005, 63 (04) :443-456
[7]   Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation [J].
Karlsson, A. ;
Gustavsson, H. ;
Mansson, S. ;
McAuley, K. B. ;
Baeck, S. A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15) :4697-4706
[8]   An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques [J].
Oldham, Mark ;
Sakhalkar, Harshad ;
Guo, Pengyi ;
Adamovics, John .
MEDICAL PHYSICS, 2008, 35 (05) :2072-2080
[9]  
Pierquet Michael, 2010, J Phys Conf Ser, V250, P1
[10]   Temperature dependence of the dose response for a solid-state radiochromic dosimeter during irradiation and storage [J].
Skyt, Peter S. ;
Balling, Peter ;
Petersen, Jorgen B. B. ;
Yates, Esben S. ;
Muren, Ludvig P. .
MEDICAL PHYSICS, 2011, 38 (05) :2806-2811