Fault ride-through capability improvement in a DFIG-based wind turbine using modified ADRC

被引:11
作者
Mosayyebi, Seyed Reza [1 ]
Shahalami, Seyed Hamid [1 ]
Mojallali, Hamed [1 ]
机构
[1] Univ Guilan, Fac Engn, Elect Engn Dept, Rasht, Iran
关键词
Doubly-fed induction generator (DFIG); Auto disturbance rejection control (ADRC); Fault ride-through (FRT); Wind turbine; Nonlinear fractional-order extended state observer (NFESO); FED INDUCTION GENERATOR; LOW-VOLTAGE RIDE; DISTURBANCE REJECTION CONTROL; POWER QUALITY CONDITIONER; CONTROL STRATEGY; PWM CONVERTERS; ENHANCEMENT; CONTROLLER; CONFIGURATION; POSITION;
D O I
10.1186/s41601-022-00272-9
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, an overview of several strategies for fault ride-through (FRT) capability improvement of a doubly-fed induction generator (DFIG)-based wind turbine is presented. Uncertainties and parameter variations have adverse effects on the performance of these strategies. It is desirable to use a control method that is robust to such disturbances. Auto disturbance rejection control (ADRC) is one of the most common methods for eliminating the effects of disturbances. To improve the performance of the conventional ADRC, a modified ADRC is introduced that is more robust to disturbances and offers better responses. The non-derivability of the fal function used in the conventional ADRC degrades its efficiency, so the modified ADRC uses alternative functions that are derivable at all points, i.e., the odd trigonometric and hyperbolic functions (arcsinh, arctan, and tanh). To improve the efficiency of the proposed ADRC, fuzzy logic and fractional-order functions are used simultaneously. In fuzzy fractional-order ADRC (FFOADRC), all disturbances are evaluated using a nonlinear fractional-order extended state observer (NFESO). The performance of the suggested structure is investigated in MATLAB/Simulink. The simulation results show that during disturbances such as network voltage sag/swell, using the modified ADRCs leads to smaller fluctuations in stator flux amplitude and DC-link voltage, lower variations in DFIG velocity, and lower total harmonic distortion (THD) of the stator current. This demonstrates the superiority over conventional ADRC and a proportional-integral (PI) controller. Also, by changing the crowbar resistance and using the modified ADRCs, the peak values of the waveforms (torque and currents) can be controlled at the moment of fault occurrence with no significant distortion.
引用
收藏
页数:37
相关论文
共 92 条
[61]  
Petrás I, 2011, NONLINEAR PHYS SCI, P55
[62]   Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG [J].
Qiao, Wei ;
Zhou, Wei ;
Aller, Jose M. ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (03) :1156-1169
[63]   Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators [J].
Qiao, Wei ;
Venayagamoorthy, Ganesh Kumar ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (01) :98-107
[64]   An Enhanced Voltage Sag Compensation Scheme for Dynamic Voltage Restorer [J].
Rauf, Abdul Mannan ;
Khadkikar, Vinod .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (05) :2683-2692
[65]   Fractional order sliding mode control of a pneumatic position servo system [J].
Ren, Hai-Peng ;
Wang, Xuan ;
Fan, Jun-Tao ;
Kaynak, Okyay .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2019, 356 (12) :6160-6174
[66]  
Riouch T, 2014, INT CONF MULTIMED, P1602, DOI 10.1109/ICMCS.2014.6911241
[67]   An optimal fuzzy PI controller to capture the maximum power for variable-speed wind turbines [J].
Sheikhan, Mansour ;
Shahnazi, Reza ;
Yousefi, Ali Nooshad .
NEURAL COMPUTING & APPLICATIONS, 2013, 23 (05) :1359-1368
[68]   Advanced Auxiliary Control of an Energy Storage Device for Transient Voltage Support of a Doubly Fed Induction Generator [J].
Shen, Yang-Wu ;
Ke, De-Ping ;
Sun, Yuan-Zhang ;
Kirschen, Daniel S. ;
Qiao, Wei ;
Deng, Xiang-Tian .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2016, 7 (01) :63-76
[69]   Model-assisted active disturbance rejection controller for maximum efficiency schemes of DFIG-based wind turbines [J].
Sobhy, Ahmed ;
Lei, Dong .
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2021, 31 (11)
[70]  
Thresher R.W., 1998, Wind Energy, V1, P70, DOI [10.1002/(SICI)1099-1824(199804)1:1+%3c70::AID-WE2%3-3.0.CO