SQUID gradiometers for a fundamental study of underwater magnetic detection

被引:9
|
作者
Hirota, M
Nanaura, K
Teranishi, Y
Kishigami, T
机构
[1] Japan Defense Agency, Kawasaki
关键词
D O I
10.1109/77.621705
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An LTS SQUID gradiometer measuring six elements of Ist order magnetic gradient was produced for a fundamental study of magnetic detection and localization under the water. It was to be installed at the sea bottom shallower than 30m and to measure magnetic noises which might degrade its detecting performance. Noises caused by the imbalance of gradiometers' pickup coils were suppressed by using auxilialy three-axis SQUID magnetometer output. The imbalance parameters were determined by measuring geomagnetic variations surrounding the sea bottom. A test for trial detection of an iron boat was conducted with a use of this gradiometer. It resulted in obtaining a higher signal-to-noise ratio for the gradiometer than that for the magnetometer.
引用
收藏
页码:2327 / 2330
页数:4
相关论文
共 50 条
  • [1] Superconducting magnetic gradiometers for underwater target detection
    Clem, TR
    NAVAL ENGINEERS JOURNAL, 1998, 110 (01) : 139 - 149
  • [2] Superconducting magnetic gradiometers for underwater target detection
    NSWC, Coastal Systems Station , United States
    不详
    不详
    不详
    Nav Eng J, 1 (139-149):
  • [3] SQUID gradiometers for archaeometry
    Chwala, A
    Stolz, R
    IJsselsteijn, R
    Schultze, V
    Ukhansky, N
    Meyer, HG
    Schüler, T
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2001, 14 (12): : 1111 - 1114
  • [4] Detection and modeling of the cardiac magnetic field using high-Tc SQUID gradiometers
    Yang, HC
    Hung, SY
    Liao, SH
    Hsu, SJ
    Wang, SY
    Chen, JC
    Chen, MJ
    Wu, CH
    Horng, HE
    Yang, SY
    Jeng, JT
    CHINESE JOURNAL OF PHYSICS, 2004, 42 (04) : 508 - 519
  • [5] MAGNETIC HYSTERESIS IN INTEGRATED LOW-TC SQUID GRADIOMETERS
    KOCH, RH
    KETCHEN, MB
    GALLAGHER, WJ
    SANDSTROM, RL
    KLEINSASSER, AW
    GAMBREL, DR
    FIELD, TH
    MATZ, H
    APPLIED PHYSICS LETTERS, 1991, 58 (16) : 1786 - 1788
  • [6] Sensitive HTS DC-SQUID gradiometers for magnetic evaluation applications
    Faley, MI
    Poppe, U
    Urban, K
    Paulson, DN
    Starr, TN
    Fagaly, RL
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 372 : 217 - 220
  • [7] SQUID gradiometers in real environments
    Vrba, J
    SQUID SENSORS: FUNDAMENTALS, FABRICATION AND APPLICATIONS, 1996, 329 : 117 - 178
  • [8] Optimization of SQUID Magnetometers and Gradiometers for Magnetic-Field-Fluctuation Thermometers
    Kirste, A.
    Drung, D.
    Beyer, J.
    Schurig, T.
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
  • [9] Improving the detection of flaws in steel pipes using SQUID planar gradiometers
    Lima, EA
    Bruno, AC
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 1299 - 1302
  • [10] Baseline distance optimization for SQUID gradiometers
    Garachtchenko, A
    Matlashov, A
    Kraus, RH
    Cantor, R
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3676 - 3679