Ability to detect endodontic complications using three different cone beam computed tomography units with and without artefact reduction modes: an ex vivo study

被引:12
作者
Koc, C. [1 ]
Kamburoglu, K. [2 ]
Sonmez, G. [2 ]
Yilmaz, F. [3 ]
Gulen, O. [4 ]
Karahan, S. [5 ]
机构
[1] Baskent Univ, Fac Dent, Dept Endodont, Ankara, Turkey
[2] Ankara Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Ankara, Turkey
[3] Ankara Univ, Dept Endodont, Fac Dent, Ankara, Turkey
[4] DentisTomo Private Imaging Ctr, Ankara, Turkey
[5] Hacettepe Univ, Dept Biostat, Fac Med, Ankara, Turkey
关键词
artefact reduction algorithms; cone beam computed tomography; endodontic complications; FILLING MATERIALS; DIAGNOSIS; INSTRUMENTS; MANAGEMENT; ALGORITHM; FRACTURE; SYSTEM; CBCT;
D O I
10.1111/iej.13051
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To assess observer performance in detecting endodontic complications using three different cone beam computed tomography (CBCT) units with and without the application of artefact reduction modes. Methodology The study involved 40 freshly extracted human mandibular teeth (n = 10 per group) and divided randomly into four endodontic complication groups. Group 1) Instrument fracture; Group 2) Strip perforation; Group 3) Canal underfilling; and Group 4) Canal overfilling. Images of each tooth were obtained using three different CBCT units offering artefact reduction algorithms: the ProMax 3D Max, the Pax Flex 3D and the Dentri S. Four observers evaluated the images for the presence/absence of the four simulated endodontic complications. Weighted kappa coefficients and intra-class correlation coefficients (ICCs) were calculated to reveal the intra- and inter-observer agreement for each imaging mode, respectively. Receiver operating characteristic (ROC) analysis was used to evaluate the observers' performance. DeLong tests were used to compare the results for each image mode and observer using a significance level of alpha = 0.05. Results In each of the four simulated endodontic complication groups, no significant differences were observed with and without application of artefact reduction for any of the three CBCT units tested. Only two significant differences were detected, and both were between the ProMax 3D Max at low mode AR and ProMax 3D Max without AR: observer 2 in group 1 (P = 0.0001) and observer 4 in group 4 (P = 0.0256). Conclusion For each of the three CBCT units tested, application of artefact reduction for detecting endodontic complications is not recommended as a routine tool.
引用
收藏
页码:725 / 736
页数:12
相关论文
共 36 条
[1]  
AAE and AAOMR, 2016, JOINT POS STAT US CO
[2]  
Angelopoulos C, 2012, ATLAS ORAL MAXILLOFA, V20, P725
[3]   Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth [J].
Bechara, B. ;
McMahan, C. Alex ;
Moore, W. S. ;
Noujeim, M. ;
Teixeira, F. B. ;
Geha, H. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
[4]   Metal artefact reduction with cone beam CT: an in vitro study [J].
Bechara, B. B. ;
Moore, W. S. ;
McMahan, C. A. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) :248-253
[5]   Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts [J].
Bezerra, I. S. Q. ;
Neves, F. S. ;
Vasconcelos, T. V. ;
Ambrosano, G. M. B. ;
Freitas, D. Q. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (06)
[6]   Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers [J].
Brito-Junior, M. ;
Santos, L. A. N. ;
Faria-e-Silva, A. L. ;
Pereira, R. D. ;
Sousa-Neto, M. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (01) :26-31
[7]   Intramanufacturer Diameter and Taper Variability of Rotary Instruments and Their Corresponding Gutta-percha Cones [J].
Chesler, Matthew B. ;
Tordik, Patricia A. ;
Imamura, Glen M. ;
Goodell, Gary G. .
JOURNAL OF ENDODONTICS, 2013, 39 (04) :538-541
[8]   A comparative study between cone-beam computed tomography and periapical radiographs in the diagnosis of simulated endodontic complications [J].
D'Addazio, P. S. S. ;
Campos, C. N. ;
Ozcan, M. ;
Teixeira, H. G. C. ;
Passoni, R. M. ;
Carvalho, A. C. P. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (03) :218-224
[9]   Performance of an artefact reduction algorithm in the diagnosis of invitro vertical root fracture in four different root filling conditions on CBCT images [J].
de Rezende Barbosa, G. L. ;
Melo, S. L. Sousa ;
Alencar, P. N. B. ;
Nascimento, M. C. C. ;
Almeida, S. M. .
INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (05) :500-508
[10]   Effect of root canal filling materials on dimensions of cone-beam computed tomography images [J].
Decurcio, Daniel Almeida ;
Bueno, Mike Reis ;
Goncalves de Alencar, Ana Helena ;
Lyra Porto, Olavo Cesar ;
Azevedo, Bruno Correa ;
Estrela, Carlos .
JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (02) :260-267