Heat transfer and pressure drop characteristics of alternating clockwise and counter clockwise twisted tape inserts in the transitional flow regime

被引:99
作者
Abolarin, S. M. [1 ]
Everts, M. [1 ]
Meyer, J. P. [1 ]
机构
[1] Univ Pretoria, Dept Mech & Aeronaut Engn, ZA-0002 Pretoria, South Africa
基金
新加坡国家研究基金会;
关键词
Transition; Clockwise; Counter clockwise; Twisted; Tape; Insert; Enhanced; FULLY-DEVELOPED FLOW; HORIZONTAL CIRCULAR TUBES; LAMINAR-FLOW; TRANSFER ENHANCEMENT; EXCHANGER TUBE; FLUID-FLOW; PERFORMANCE ASSESSMENT; TRANSFER AUGMENTATION; THERMAL PERFORMANCES; TRANSFER COEFFICIENT;
D O I
10.1016/j.ijheatmasstransfer.2018.12.107
中图分类号
O414.1 [热力学];
学科分类号
摘要
The purpose of this study was to experimentally investigate the heat transfer and pressure drop characteristics in a smooth circular tube with alternating clockwise and counter clockwise twisted tape (CCCTT) inserts. The CCCTT inserts were fabricated from copper plate strips with a length, width and thickness of 450 mm, 18 mm and 1 mm respectively. The strips were twisted to obtain a twist ratio of 5 and 12 strips were joined longitudinally so that a clockwise direction twisted tape insert was connected to a counter clockwise direction twisted tape. The assembling was at connection angles of 0, 30 and 60, to form CCCTT inserts with an overall length of 5.27 m. The CCCTT inserts were placed in a smooth circular copper tube with an inner diameter of 19 mm. Water was used as the test fluid and experiments were conducted at constant heat fluxes of 135, 2, 3 and 4 kW/m(2) between Reynolds numbers of 300 and 11,404. This covered the laminar, transitional and turbulent flow regimes. Specific attention was given to the identification of the transitional flow regime with the CCCTT inserts and the influence of the connection angle and heat flux on the transitional flow regime. It was found that both the start and the end of the transitional flow regime were influenced by the connection angle and the heat flux. When different connection angles were compared it was found that an increase in connection angle enhanced the heat transfer in the transitional flow regime. An increase in heat flux significantly enhanced the heat transfer in the laminar flow regime and delayed transition. Heat transfer and pressure drop correlations were developed to predict the experimental data in the laminar, transitional and turbulent regimes as a function Reynolds number, modified Grashof number and connection angle. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:203 / 217
页数:15
相关论文
共 79 条
[1]   Experimental investigation of turbulent heat transfer by counter and co-swirling flow in a flat tube fitted with twin twisted tapes [J].
Abdolbaqi, M. Kh. ;
Azmi, W. H. ;
Mamat, Rizalman ;
Mohamed, N. M. Z. N. ;
Najafi, G. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 75 :295-302
[2]   The influence of peripheral u-cut twisted tapes and ring inserts on the heat transfer and pressure drop characteristics in the transitional flow regime [J].
Abolarin, S. M. ;
Everts, M. ;
Meyer, J. P. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 132 :970-984
[3]   Pressure drop and heat transfer comparison for both microfin tube and twisted-tape inserts in laminar flow [J].
Al-Fahed, S ;
Chamra, LM ;
Chakroun, W .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 18 (04) :323-333
[4]   Convective heat transfer enhancement inside tubes using inserted helical coils [J].
Ali R.K. ;
Sharafeldeen M.A. ;
Berbish N.S. ;
Moawed M.A. .
Thermal Engineering, 2016, 63 (01) :42-50
[5]  
Allen RW., 1964, Journal of Heat Transfer, V86, P301, DOI DOI 10.1115/1.3688680
[6]   THE EFFECT OF GAP WIDTH BETWEEN HORIZONTAL TUBE AND TWISTED TAPE ON THE PRESSURE-DROP IN TURBULENT WATER-FLOW [J].
AYUB, ZH ;
ALFAHED, SF .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1993, 14 (01) :64-67
[7]   INFLUENCE OF FREE-CONVECTION ON HEAT-TRANSFER DURING LAMINAR-FLOW IN TUBES WITH TWISTED TAPES [J].
BANDYOPADHYAY, PS ;
GAITONDE, UN ;
SUKHATME, SP .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1991, 4 (05) :577-586
[8]   Optimization of Parameters for Heat Transfer and Pressure Drop in a Tube with Twisted Tape Inserts by Using Taguchi Method [J].
Bas, Halit ;
Ozceyhan, Veysel .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (02) :1177-1186
[9]   Thermohydraulics of laminar flow through a circular tube having integral helical rib roughness and fitted with centre-cleared twisted-tape [J].
Bhattacharyya, Suvanjan ;
Saha, Sujoy Kumar .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 42 :154-162
[10]   Heat transfer augmentation in a circular tube with perforated double counter twisted tape inserts [J].
Bhuiya, M. M. K. ;
Azad, A. K. ;
Chowdhury, M. S. U. ;
Saha, M. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 74 :18-26