Several approaches for vitamin D determination by surface plasmon resonance and electrochemical affinity biosensors

被引:59
作者
Carlucci, Luciano [1 ]
Favero, Gabriele [1 ]
Tortolini, Cristina [1 ]
Di Fusco, Massimo [2 ]
Romagnoli, Elisabetta [3 ]
Minisola, Salvatore [3 ]
Mazzei, Franco [1 ]
机构
[1] Univ Roma La Sapienza, Dept Chem & Drug Technol, I-00185 Rome, Italy
[2] Univ Bologna, Adv Applicat Mech Engn & Mat Technol Interdept Ct, I-40100 Bologna, Italy
[3] Univ Roma La Sapienza, Dept Clin Sci, I-00161 Rome, Italy
关键词
Vitamin D; Affinity biosensors; Surface Plasmon Resonance; Electrochemical transduction; 25-hydroxyvitamin D; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; D DEFICIENCY; 25-HYDROXYVITAMIN D-2; D INSUFFICIENCY; D INADEQUACY; PREVALENCE; CONSEQUENCES; HEALTH;
D O I
10.1016/j.bios.2012.07.077
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This work has been focused on the development of novel optical (Surface Plasmon Resonance) and electrochemical based biosensors for the determination of 25-OH vitamin D (25OHD) which is an important factor involved in avoiding both skeletal damage and a variety of pathological conditions, and to evaluate their potential use in clinical practice. Different approaches to the determination of vitamin D using affinity based biosensors, are described herein; firstly, an immunosensor based on SPR transduction was realized for direct determination of vitamin D, obtaining a LOD of 2 mu g/ml which unfortunately is too far from the needs in clinical analysis. In order to enhance the sensitivity, the vitamin D was modified with gold nanoparticles (AuNPs): the binding of 25OHD with AuNPs determines the amplification of SPR signal, allowing to lower the LOD down to 1 mu g/ml, doubling the sensitivity. An alternative SPR method, based on the indirect determination of vitamin D by means of Vitamin D Binding Protein (VDBP), led to a further sensitivity increase reaching a LOD of 45 ng/ml which is really close to the fixed accomplishment. Finally, an electrochemical transduced biosensor has been realized, based on the reaction of vitamin D with 4-ferrocenylmethyl-1,2,4-triazoline-3,5-dione (FMTAD): once derivatized, the determination of 25OHD was possible in the range 20-200 ng/ml with a LOD of 10 ng/ml. The latter proposed system fits the requirement of determining vitamin D in a concentration range which is of significance for clinical applications; moreover, since a screen printed electrode has been used, this opens the possibility to miniaturize the sensor and developing a portable and easy-to-automate point-of-care testing device. The proposed devices provide an improvement with respect to traditional methods that are time and reagents consuming and require radioactive compounds, pretreatment procedures and expensive instrumentation. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 355
页数:6
相关论文
共 26 条
  • [1] Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3
    Adamec, Jiri
    Jannasch, Amber
    Huang, Jianjie
    Hohman, Emily
    Fleet, James C.
    Peacock, Munro
    Ferruzzi, Mario G.
    Martin, Berdine
    Weaver, Connie M.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 11 - 20
  • [2] Bischoff-Ferrari HA, 2006, AM J CLIN NUTR, V84, P1253
  • [3] Prevalence of vitamin D insufficiency in an adult normal population
    Chapuy, MC
    Preziosi, P
    Maamer, M
    Arnaud, S
    Galan, P
    Hercberg, S
    Meunier, PJ
    [J]. OSTEOPOROSIS INTERNATIONAL, 1997, 7 (05) : 439 - 443
  • [4] Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology
    Daniel, MC
    Astruc, D
    [J]. CHEMICAL REVIEWS, 2004, 104 (01) : 293 - 346
  • [5] Estimates of optimal vitamin D status
    Dawson-Hughes, B
    Heaney, RP
    Holick, MF
    Lips, P
    Meunier, PJ
    Vieth, R
    [J]. OSTEOPOROSIS INTERNATIONAL, 2005, 16 (07) : 713 - 716
  • [6] Vitamin D
    Dusso, AS
    Brown, AJ
    Slatopolsky, E
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2005, 289 (01) : F8 - F28
  • [7] Surface Plasmon Resonance Analysis of Antibiotics Using Imprinted Boronic Acid-Functionalized Au Nanoparticle Composites
    Frasconi, Marco
    Tel-Vered, Ran
    Riskin, Michael
    Willner, Itamar
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (06) : 2512 - 2519
  • [8] Surface plasmon resonance immunosensor for cortisol and cortisone determination
    Frasconi, Marco
    Mazzarino, Monica
    Botre, Francesco
    Mazzei, Franco
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (08) : 2151 - 2159
  • [9] Calcium absorption varies within the reference range for serum 25-hydroxyvitamin D
    Heaney, RP
    Dowell, MS
    Hale, CA
    Bendich, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2003, 22 (02) : 142 - 146
  • [10] High prevalence of vitamin D inadequacy and implications for health
    Holick, MF
    [J]. MAYO CLINIC PROCEEDINGS, 2006, 81 (03) : 353 - 373