Utilising a Lagrangian approach to compute maximum fault current in hybrid AC-DC distribution grids with MMC interface

被引:6
作者
Negari, Shahram [1 ]
Xu, David [1 ]
机构
[1] Ryerson Univ, Dept Elect & Comp Engn, 350 Victoria St, Toronto, ON M5B 2K3, Canada
关键词
power grids; AC-DC power convertors; distribution networks; wind power plants; overcurrent protection; power convertors; renewable energy sources; power distribution faults; fault currents; distributed power generation; fault diagnosis; Lagrangian approach; maximum fault current; hybrid AC-DC distribution grids; MMC interface; hybrid AC-DC networks; high-voltage transmission; medium-voltage distribution grids; distributed generation; modular multilevel converters; hybrid networks; worst-case scenario; critical design factor; reliable protection scheme; Lagrangian energy method; maximal fault magnitude; internal energy; weak AC sources; high internal impedance; salient contributing factor; destructive faults; simulated medium-voltage hybrid AC-DC; MODULAR-MULTILEVEL-CONVERTER; CONTROL STRATEGY; PROTOTYPE;
D O I
10.1049/hve.2018.5087
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Hybrid AC-DC networks are transforming high-voltage transmission and medium-voltage distribution grids by embracing the advantages of both AC and DC systems, which facilitates the inclusion of renewable energy sources and distributed generation. As modular multilevel converters (MMCs) are vastly employed in such hybrid networks, determining their maximal fault current in worst-case scenario is a critical design factor for planning and implementation of a reliable protection scheme. This study develops a novel mathematical framework that applies a Lagrangian energy method to calculate the maximal fault magnitude. This method allows to account for converter's internal energy and compute its impact on the amplitude of the fault current. It is shown when the converter is interfacing weak AC sources with high internal impedance such as wind farms or solar farms, dumping the internal energy of the converter into the fault is the salient contributing factor of the fault magnitude. Furthermore, to distinguish and classify the output overcurrent as either ignorable transients or destructive faults, a perceptron with sigmoid threshold is employed. The model is verified using a simulated medium-voltage hybrid AC-DC distribution network.
引用
收藏
页码:18 / 27
页数:10
相关论文
共 43 条
[1]  
Andrade V. D., 2010, 2010 IEEE/PES Transmission & Distribution Conference & Exposition: Latin America (T&D-LA 2010), P602, DOI 10.1109/TDC-LA.2010.5762944
[2]  
[Anonymous], 2016, IEEE INT ENER CONF, DOI DOI 10.1109/ENERGYCON.2016.7513914
[3]  
[Anonymous], 2007, POWER ELECT CONVERTE
[4]  
[Anonymous], 2011, Power Electron. Appl. (EPE 2011)
[5]  
[Anonymous], 2009, P 13 EUR C POW EL AP
[6]  
[Anonymous], P CHIN INT C EL DIST
[7]  
[Anonymous], 2016, HVDC GRIDS OFFSHORE
[8]  
Athari M. H., 2017, ARXIV170602754
[9]  
Bishop R.H., 2005, MECHATRONICS INTRO
[10]  
Bollen M. H., 2011, SYNTHESIS LECT POWER, V2, P1, DOI DOI 10.1007/978-3-031-02496-2