Low-Order Response Modeling for Wind Farm-MTDC Participating in Primary Frequency Controls

被引:23
|
作者
Ye, Hua [1 ,2 ]
Pei, Wei [1 ,2 ]
Kong, Li [1 ,2 ]
An, Ting [3 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 101408, Peoples R China
[3] Global Energy Interconnect Res Inst, Beijing 102211, Peoples R China
基金
中国国家自然科学基金;
关键词
Linear quadratic regulation (LQR); multi-terminal HVDC; system response model; transfer functions; virtual synchronousmachine (VSM); voltage source converter (VSC); wind farms; ADAPTIVE DROOP CONTROL; VSC-HVDC; SYSTEM; SUPPORT; MICROGRIDS;
D O I
10.1109/TPWRS.2018.2874042
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A low-order and system-level response model for wind farms (WFs) and voltage source converter based high-voltage direct current (VSC-HVDC) participating in primary frequency regulation using virtual synchronous machine (VSM) control is developed and validated. The VSM control with virtual power system stabilizer (PSS) function is presented being applicable to all multi-terminal HVDC (MTDC) VSCs. In this context, a general low-order response model (LRM) for presenting the WF-MTDC participating in the frequency control of main AC system is readily established. This modeling method derives transfer function based block diagram offering an illustrative insight into dynamic interaction between AC frequencies and DC voltages. Such a model can also provide a convenient way performing control system designing and parameter tuning. As a paradigm, LRM-based linear quadratic regulation optimization is applied to obtain the droop and damping gains for feasible frequency regulation. The effectiveness of the LRM method is verified through comparisons of the simulation results obtained from different models, controller designs, and parameter tuning approaches, which are all performed on a five-terminal VSC-HVDC connecting WF-side and main AC systems.
引用
收藏
页码:942 / 952
页数:11
相关论文
共 36 条
  • [1] A low-order model for wind farm control
    Annoni, Jennifer
    Seiler, Peter
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 1721 - 1727
  • [2] Low-order modeling of wind farm aerodynamics using leaky Rankine bodies
    Araya, Daniel B.
    Craig, Anna E.
    Kinzel, Matthias
    Dabiri, John O.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (06)
  • [3] A LOW-ORDER SYSTEM FREQUENCY-RESPONSE MODEL
    ANDERSON, PM
    MIRHEYDAR, M
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1990, 5 (03) : 720 - 729
  • [4] Wind farm density and harvested power in very large wind farms: A low-order model
    Cortina, G.
    Sharma, V.
    Calaf, M.
    PHYSICAL REVIEW FLUIDS, 2017, 2 (07):
  • [5] Sequence Control Method for VSC-MTDC System with Offshore Wind Farm Participating in Frequency Regulation of Power Grid
    Yu G.
    Song H.
    Ma G.
    Qu Y.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (04): : 123 - 132
  • [6] Low-order modeling of low-frequency combustion instabilities in aeroengines
    Eckstein, J
    Sattelmayer, T
    JOURNAL OF PROPULSION AND POWER, 2006, 22 (02) : 425 - 432
  • [7] Wind Farm with HVDC Delivery in Inertial and Primary Frequency Response
    Fan, Lingling
    Miao, Zhixin
    Osborn, Dale
    Green Energy and Technology, 2012, 78 : 465 - 483
  • [8] Dynamical systems modeling of low-frequency variability in low-order atmospheric models
    Broer, Henk
    Vitolo, Renato
    DISCRETE AND CONTINUOUS DYNAMICAL SYSTEMS-SERIES B, 2008, 10 (2-3): : 401 - 419
  • [9] RETRACTED: Low-order frequency response model in the application of frequency control (Retracted Article)
    Gao, Zheng
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 3820 - 3825
  • [10] Development of a Controller to Provide Primary Frequency Response Capability for a Wind Farm
    Feltes, James W.
    Fernandes, Bernardo S.
    Senthil, Jayapalan
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,