A case study on detection and sizing of defects in steam generator tubes using eddy current testing

被引:17
|
作者
Hur, Do Haeng [1 ]
Choi, Myung Sik [1 ]
Lee, Deok Hyun [1 ]
Kim, Seon Jin [2 ]
Han, Jung Ho [1 ]
机构
[1] Korea Atom Energy Res Inst, Taejon 305353, South Korea
[2] Hanyang Univ, Div Mat Sci & Engn, Seoul 133791, South Korea
关键词
CORROSION; FRANCE;
D O I
10.1016/j.nucengdes.2009.10.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Eddy current testing (ECT) method is widely used to detect various types of defects occurring in nuclear steam generator tubes. Therefore, the reliability of its detection and sizing accuracy for defects should be validated. For this purpose, two tubes with defect signals were pulled from an operating steam generator and destructively examined. The defect type was a circumferential crack for one tube and an intergranular attack (IGA) for the other tube. The plus point coil probe showed a better capability to detect and size both a circumferential crack and a volumetric IGA than pancake and bobbin coil probe. The destructive results are correlated with the ECT results obtained during the in-service inspection. (C) 2009 Elsevier B.V. All rights reserved.