Graduation of the Instrument Transducers with Integrated Pick-Ups

被引:0
|
作者
Emets, S., V [1 ]
Polischouk, I. N. [2 ]
Kudayarov, V. N. [1 ]
机构
[1] Ufa State Petr Technol Univ, Fac Ind Proc Automat, Ufa, Russia
[2] Gazprom Transgaz Ufa LLC, Ufa, Russia
来源
2020 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM) | 2020年
关键词
graduation; measuring transducer; integrated pick-up; measured quantity; influencing quantity; additional error; SENSORS;
D O I
10.1109/icieam48468.2020.9111991
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The successful operation of a modern production facility is impossible without the omnipresent use of information measuring systems. In turn, the data capacity of the latter is largely determined by the metrological characteristics of the physical quantities measuring transducers used and, in particular, by the minimal additional errors from the various influencing factors. Widely used semiconductor sensors are characterized by the integrated type pick-ups, therefore, they are sensitive to a whole range of influencing physical quantities. Some of them are natural input or measured quantities of measuring transducers, and the rest are interferences or influencing quantities in relation to the primary ones and determine additional errors. A multifactorial graduation experiment is necessary in order to obtain the measuring transducer conversion function for the measured quantities and correct the influence of additional errors. It involves the transducer influenced by various combinations of metrologically provided and time-stabilized measured and influencing quantities and the subsequent construction of the conversion function mathematical model. In practice, situations often arise when it is impossible to stabilize and accurately set or measure the influencing factor. For such case, the article includes a theoretical justification and practical possibility testing of conducting a graduation experiment without influencing factors stabilization and measurement. The proposed approach to the graduation of measuring transducers with an integrated pick-up enables to increase their resistance to the influencing factors in the entire operational range and reduce the corresponding additional errors.
引用
收藏
页数:5
相关论文
共 10 条
  • [1] Verbal feedback in therapeutic communities: pull-ups and reciprocated pull-ups as predictors of graduation
    Warren, Keith
    Hiance, Danielle
    Doogan, Nathan
    De Leon, George
    Phillips, Gary
    JOURNAL OF SUBSTANCE ABUSE TREATMENT, 2013, 44 (04) : 361 - 368
  • [2] Piezoelectric thin films: an integrated review of transducers and energy harvesting
    Khan, Asif
    Abas, Zafar
    Kim, Heung Soo
    Oh, Il-Kwon
    SMART MATERIALS AND STRUCTURES, 2016, 25 (05)
  • [3] Application of the C5.0 Algorithm for Student Graduation Integrated with Academic Information Systems
    Dharma, Abdi
    Lase, Sonia N.
    Laia, Yonata
    Turnip, Mardi
    Turnip, Mardi
    INTERNETWORKING INDONESIA, 2020, 12 (02): : 13 - 17
  • [4] Three Dimensional Modeling of Piezoelectric Micromachined Transducers Built on Top of Integrated Circuits
    Chan, Kevin
    Patel, Mihir
    Barniol, Nuria
    Bhowmick, Shomnath
    Cases, Sebastien
    Wong, Angela
    2020 IEEE ELECTRON DEVICES TECHNOLOGY AND MANUFACTURING CONFERENCE (EDTM 2020), 2020,
  • [5] WSN Integrated to a Virtual Instrument for Partial Discharges Detection and Localization
    L Vianna De Omena, R. A.
    Silva, J. J.
    da Rocha Neto, J. S.
    2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 1865 - 1870
  • [6] On-Chip Feedthrough Cancellation Methods for Microfabricated AFM Cantilevers With Integrated Piezoelectric Transducers
    Coskun, M. Bulut
    Fowler, Anthony G.
    Maroufi, Mohammad
    Moheimani, S. O. Reza
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2017, 26 (06) : 1287 - 1297
  • [7] Structural health monitoring of rotary aerospace structures based on electromechanical impedance of integrated piezoelectric transducers
    Hoshyarmanesh, Hamidreza
    Abbasi, Ali
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2018, 29 (09) : 1799 - 1817
  • [8] Electromechanical admittance based integrated health monitoring of adhesive bonded beams using surface bonded piezoelectric transducers
    Rautela, Mahindra
    Bijudas, C. R.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2019, 94 : 84 - 98
  • [9] 240-GHz Reflectometer-Based Dielectric Sensor With Integrated Transducers in a 130-nm SiGe BiCMOS Technology
    Wang, Defu
    Eissa, Mohamed Hussein
    Schmalz, Klaus
    Kaempfe, Thomas
    Kissinger, Dietmar
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (01) : 1027 - 1035
  • [10] Multi-Task Deep Transfer Learning Method for Guided Wave-Based Integrated Health Monitoring Using Piezoelectric Transducers
    Zhang, Bin
    Hong, Xiaobin
    Liu, Yuan
    IEEE SENSORS JOURNAL, 2020, 20 (23) : 14391 - 14400