Performance of frequency-doubling technology perimetry in a population-based prevalence survey of glaucoma - The Tajimi study

被引:45
作者
Iwase, Aiko
Tomidokoro, Atsuo
Araie, Makoto
Shirato, Shiroaki
Shimizu, Hiroyuki
Kitazawa, Yoshiaki
机构
[1] Univ Tokyo, Grad Sch Med, Dept Ophthalmol, Bunkyo Ku, Tokyo 1138655, Japan
[2] Tajimi Municipal Hosp, Dept Ophthalmol, Tajimi, Japan
[3] Yotsuya Shirato Eye Clin, Tokyo, Japan
[4] Gifu Univ, Grad Sch Med, Dept Epidemiol & Prevent Med, Gifu, Japan
[5] Akasaka Kitazawa Eye Clin, Tokyo, Japan
关键词
D O I
10.1016/j.ophtha.2006.06.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the performance of frequency-doubling technology (FDT) perimetry in a population-based glaucoma prevalence survey. Design: Population-based cross-sectional study. Participants: Participants older than 40 years randomly selected from the population of Tajimi City. Methods: Each participant underwent screening ophthalmic examinations including a visual field test using FDT with the C-20-1 screening protocol. A diagnosis of glaucoma was determined by glaucoma specialists with another detailed visual field test using Humphrey Field Analyzer (HFA; Humphrey Instruments, San Leandro, CA) with the 30-2 Swedish interactive threshold algorithm standard protocol and stereoscopic disc photographs. Main Outcome Measures: The ratios of reliable FDT results and the sensitivity and specificity for detecting glaucoma in a general population. Results: Of 5784 eyes of 2892 participants (age range, 40-92 years; refractive error, -23 to 11 diopters) in whom FDT was performed in both eyes, reliable results (<= 33% fixation loss and <= 33% false-positive errors) were obtained in 5707 eyes (98.7%), including 2871 right eyes (99.3%) and 2836 left eyes (98.1%) with a significant bilateral difference (P < 0.001, chi-square test). The rate of reliable FDT results did not differ between men and women (P = 0.81) but decreased with age. In 5582 eyes with reliable FDT results, FDT showed 1 or more abnormal points in the visual field in 502 eyes (9.0%), including 388 (7.3%) of 5295 normal eyes, 19 (16.4%) of 116 eyes of glaucoma suspects, and 95 (55.6%) of 171 eyes with definite glaucoma. The sensitivity and specificity values for detecting definite glaucoma were 55.6% and 92.7%, respectively. The positive and negative predictive values were 18.9% and 98.5%, respectively. In further analyses stratified with the mean deviation (MD) of the HFA, the sensitivities were 32.1%, 48.4%, 73.7%, and 96.6% for detecting definite glaucoma with an MD of more than -2 dB, an MD of -2 dB or less and more than -5 dB, an IVID of -5 dB or less and more than -8 dB, and an MD of -8 dB or less, respectively. Conclusions: In a population-based glaucoma screening study, FDT perimetry with the C-20-1 screening protocol was reliably performed in more than 98% of participants. The sensitivity for detecting glaucomatous visual field damages, especially early damage, was not sufficiently high, whereas the specificity was high.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 21 条
[1]   Normal aging effects for frequency doubling technology perimetry [J].
Adams, CW ;
Bullimore, MA ;
Wall, M ;
Fingeret, M ;
Johnson, CA .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) :582-587
[2]   Effect of dichoptic adaptation on frequency-doubling perimetry [J].
Anderson, AJ ;
Johnson, CA .
OPTOMETRY AND VISION SCIENCE, 2002, 79 (02) :88-92
[3]  
Anderson D.R., 1999, Automated Static Perimetry, P152
[4]   Effects of blur and repeated testing on sensitivity estimates with frequency doubling perimetry [J].
Artes, PH ;
Nicolela, MT ;
McCormick, TA ;
LeBlanc, RP ;
Chauhan, BC .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (02) :646-652
[5]   Prevalence of glaucoma and intraocular pressure distribution in a defined population -: The Egna-Neumarkt study [J].
Bonomi, L ;
Marchini, G ;
Marraffa, M ;
Bernardi, P ;
De Franco, I ;
Perfetti, S ;
Varotto, A ;
Tenna, V .
OPHTHALMOLOGY, 1998, 105 (02) :209-215
[6]   Frequency doubling technology perimetry for detection of glaucomatous visual field loss [J].
Cello, KE ;
Nelson-Quigg, JM ;
Johnson, CA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :314-322
[7]  
Cioffi G A, 2000, Trans Am Ophthalmol Soc, V98, P195
[8]  
Fingeret M, 2001, PERIMETRY UPDATE 2000/2001, P271
[9]   Performance of glaucoma mass screening with only a visual field test using frequency-doubling technology perimetry [J].
Iwasaki, A ;
Sugita, M .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (04) :529-537
[10]   The prevalence of primary open-angle glaucoma in Japanese - The Tajimi study [J].
Iwase, A ;
Suzuki, Y ;
Araie, M ;
Yamamoto, T ;
Abe, H ;
Shirato, S ;
Kuwayama, Y ;
Mishima, HK ;
Shimizu, H ;
Tomita, G ;
Inoue, Y ;
Kitazawa, Y .
OPHTHALMOLOGY, 2004, 111 (09) :1641-1648