Noise measurements and optimization of the high sensitivity capacitive transducer of AURIGA

被引:9
|
作者
Marin, A
Bignotto, M
Bonaldi, M
Cerdonio, M
Falferi, P
Mezzena, R
Prodi, GA
Soranzo, G
Taffarello, L
Vinante, A
Vitale, S
Zendri, JP
机构
[1] Univ Padua, Dipartimento Fis, I-35100 Padua, Italy
[2] Ist Nazl Fis Nucl, Sez Padova, I-35100 Padua, Italy
[3] CNR, ITC, Ctr Fis Stati Aggregati, I-38050 Trent, Povo Trento, Italy
[4] Ist Nazl Fis Nucl, Grp Coll, I-38050 Trent, Povo Trento, Italy
[5] Univ Trent, Dipartimento Fis, I-38050 Trent, Povo, Italy
关键词
D O I
10.1088/0264-9381/19/7/404
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Tests of the new AURIGA readout have recently started in the AURIGA ultracryogenic test facility. The most important modifications, with respect to the previous version of the readout, are a new, heavier, resonant capacitive transducer, the tuning of the electrical mode to the two mechanical ones and the use of a low noise two-stage SQUID amplifier. Results regarding the quality factor and the noise of the transducer mechanical and electrical modes are presented.
引用
收藏
页码:1991 / 1996
页数:6
相关论文
共 50 条
  • [41] Long range, high sensitivity, low noise capacitive sensor for tagless indoor human localization
    Iqbal, Javed
    Lazarescu, Mihai Teodor
    Bin Tariq, Osama
    Lavagno, Luciano
    2017 7TH IEEE INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES (IWASI), 2017, : 189 - 194
  • [42] An alternative capacitive transducer design for sensitivity enhancement in MEMS Lorentz force magnetometers
    Zakriya Mohammed
    Daniel S. Choi
    Ibrahim M. Elfadel
    Microsystem Technologies, 2024, 30 : 221 - 230
  • [43] Capacitive micromachined ultrasonic transducer design for high power transmission
    Bayram, B
    Oralkan, Ö
    Ergun, AS
    Hæggström, E
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (02) : 326 - 339
  • [44] A DEVICE FOR THE CAPACITIVE MEASUREMENT OF PRESSURE DISTRIBUTION WITH HIGH TRANSDUCER DENSITY
    BRUNNER, W
    KURZ, B
    DIEBSCHLAG, W
    BIOMEDIZINISCHE TECHNIK, 1983, 28 (10): : 221 - 224
  • [45] Nanoindentation and picoindentation measurements using a capacitive transducer system in atomic force microscopy
    Bhushan, B
    Kulkarni, AV
    Bonin, W
    Wyrobek, JT
    PHILOSOPHICAL MAGAZINE A-PHYSICS OF CONDENSED MATTER STRUCTURE DEFECTS AND MECHANICAL PROPERTIES, 1996, 74 (05): : 1117 - 1128
  • [46] Smart Capacitive Transducer for High-Frequency Vibration Measurement
    Augutis, Vygantas
    Balciunas, Gintautas
    Kuzas, Pranas
    Gailius, Darius
    Raudiene, Edita
    SENSORS, 2025, 25 (06)
  • [48] OPTIMIZATION OF NOISE PARAMETER MEASUREMENTS
    KUZNETSO.VP
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1972, 26 (07) : 105 - 109
  • [49] Sensitivity and noise characteristics of EROS measurements
    Maclin, E
    Gratton, G
    Fabiani, M
    JOURNAL OF COGNITIVE NEUROSCIENCE, 2002, : 38 - 38
  • [50] The temperature influence on the piezoelectric transducer noise, measurements and modeling.