Amperometric ATP biosensor based on polymer entrapped enzymes

被引:94
作者
Kueng, A [1 ]
Kranz, C [1 ]
Mizaikoff, B [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
基金
美国国家科学基金会; 奥地利科学基金会;
关键词
ATP biosensor; hexokinase; glucose oxidase; microelectrode; amperometric sensor; polymerization;
D O I
10.1016/j.bios.2003.11.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A dual enzyme electrode for the detection of adenosine-5'-triphosphate (ATP) at physiologically relevant pH levels was developed by co-immobilization of the enzymes glucose oxidase (GOD) and hexokinase (HEX) using pH-shift induced deposition of enzyme containing polymer films. Application of a simple electrochemical procedure for the co-immobilization of the enzymes at electrode surfaces exhibits a major improvement of sensitivity, response time, reproducibility, and ease of fabrication of ATP bbiosensors. Competition between glucose oxidase and hexokinase for the substrate glucose involving ATP as a co-substrate allows the determination of ATP concentrations. Notable control on the immobilization process enables fabrication of micro biosensors with a diameter of 25 mum. The presented concept provides the technological basis for a new generation of fast responding, sensitive, and robust biosensors for the detection of ATP at physiological pH values with a detection limit of 10 nmol1(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1301 / 1307
页数:7
相关论文
共 30 条
[1]   INTRACELLULAR ANALYSIS WITH AN IMMOBILIZED-ENZYME GLUCOSE ELECTRODE HAVING A 2-MU-M DIAMETER AND SUBSECOND RESPONSE-TIMES [J].
ABE, T ;
LAU, YY ;
EWING, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (19) :7421-7423
[2]   CHARACTERIZATION OF GLUCOSE MICROSENSORS FOR INTRACELLULAR MEASUREMENTS [J].
ABE, T ;
LAU, YY ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2160-2163
[3]   NA+,K+-ATPASE-BASED BILAYER-LIPID MEMBRANE SENSOR FOR ADENOSINE 5'-TRIPHOSPHATE [J].
ADACHI, Y ;
SUGAWARA, M ;
TANIGUCHI, K ;
UMEZAWA, Y .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :577-584
[4]   Step-by-step avidin-biotin construction of bienzyme electrodes.: Kinetic analysis of the coupling between the catalytic activities of immobilized monomolecular layers of glucose oxidase and hexokinase [J].
Anicet, N ;
Bourdillon, C ;
Moiroux, J ;
Savéant, JM .
LANGMUIR, 1999, 15 (19) :6527-6533
[5]  
[Anonymous], REV MOL BIOTECHNOL, DOI DOI 10.1016/S1389-0352(01)00058-7
[6]   Glucose oxidase/hexokinase electrode for the determination of ATP [J].
Compagnone, D ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :109-113
[7]   Capillary biosensor for glutamate [J].
Cosford, RJO ;
Kuhr, WG .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2164-2169
[8]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[9]   Application of conducting polymers to biosensors [J].
Gerard, M ;
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) :345-359
[10]   A MICROSENSOR FOR ADENOSINE-5'-TRIPHOSPHATE PH-SENSITIVE FIELD-EFFECT TRANSISTORS [J].
GOTOH, M ;
TAMIYA, E ;
KARUBE, I ;
KAGAWA, Y .
ANALYTICA CHIMICA ACTA, 1986, 187 :287-291