Optimization and characterisation of commercial water-based volatile corrosion inhibitor

被引:2
|
作者
Cheng, N. [1 ]
Valdez-Salas, B. [2 ]
Moe, P. [1 ]
Salvador-Carlos, J. S. [2 ]
机构
[1] Magna Int Pte Ltd, 10 H Enterprise Rd, Singapore 629834, Singapore
[2] UABC, Inst Ingn, Mat Avanzados & Corros, Mexicali Calle Normal S-N,Parcela 44, Mexicali 21100, Baja California, Mexico
来源
INTERNATIONAL JOURNAL OF CORROSION AND SCALE INHIBITION | 2019年 / 8卷 / 02期
关键词
corrosion inhibitor; vapour phase protection; dip-coating;
D O I
10.17675/2305-6894-2019-8-2-16
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Volatile corrosion inhibitor (VCI) provides protection for metal surfaces. VCI coating and molecules attach themselves to metal surfaces to form both a physical film when contacted and an invisible thin film for indirect contact through Vapour (only a few molecules thick), thus inhibiting metals atmospheric corrosion. Optimization and characterisation of commercial water-based volatile corrosion inhibitor VCI (Vapour-Phase-Protection, VAPPRO 837C diluted commercial solution from CORPPRO) was prepared to determine their characteristics and effectiveness against corrosion of carbon steel. The main scope of this work is to characterise the rheological and corrosion inhibition properties of the VAPPRO 837C with varying formulations and processing parameters (coating and drying times). Different tests were performed to determine the corrosion behavior of inhibitor. The application of VCI on the metal surface was done by dip-coating process. An Electrochemical Workstation from HCH Instruments has been used to evaluate the corrosion inhibition efficiency of the VCI and to determine the corrosion rate of the uncoated and coated samples. In addition, viscosity tests were carried out in order to determine the rheological properties of the formulation, as well as Freeze-Thaw resistance of water-borne coatings and pH tests were done. A FTIR spectrometer has been used to determine the functional groups present at a specific concentration. Results reveal that the most effective VCI film was obtained from a 0.25 CORPPRO (Concentrated VCI) (vol%) formulation using a coating time of 10 min and a drying time of 24 h. Therefore, 0.25 CORPPRO would be the optimum concentration to be used because it is able to achieve the highest corrosion inhibition efficiency with the optimum coating drying time.
引用
收藏
页码:366 / +
页数:21
相关论文
共 50 条
  • [1] Corrosion inhibition performance of an environmentally friendly water-based nano-inhibitor
    Zhu, Xiaoli
    Wang, Chusheng
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 70 : 495 - 501
  • [2] Experiment and numerical simulation of distribution law of water-based corrosion inhibitor in natural gas gathering and transportation pipeline
    Liu, En -Bin
    Tang, Hao
    Zhang, Yin-Hui
    Li, Dang-Jian
    Kou, Bo
    Liu, Ning
    Azimi, Mohammadamin
    PETROLEUM SCIENCE, 2023, 20 (03) : 1857 - 1873
  • [3] AN INVESTIGATION ON THE PERFORMANCE OF AN IMIDAZOLINE BASED COMMERCIAL CORROSION INHIBITOR ON CO2 CORROSION OF MILD STEEL
    Khavasfar, A.
    Moayed, M. H.
    Jafari, A. H.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2007, 20 (01): : 35 - 44
  • [4] Effects of Corrosion Inhibitor on Corrosion of Al-based Alloys in Ethylene Glycol-Water Coolant Environment
    Choi, Gwang-Soo
    Kim, Young -Man
    Park, Chan-Jin
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2023, 22 (05): : 305 - 313
  • [5] Evaluation of Limonene-Based Compound as Volatile Inhibitor to Protect AISI 1020 Carbon Steel Against Corrosion
    Pereira, Mariana S. G.
    Leal, Debora A.
    Mor, Filipe M.
    da Silva, Bruno C.
    Marino, Claudia E. B.
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2025, 28
  • [6] Optimization of synthesis of a sulfonate hydrogen sulfide corrosion inhibitor
    Z. R. Agaeva
    K. I. Sadykhov
    F. M. Velieva
    I. G. Melikova
    Chemistry and Technology of Fuels and Oils, 2010, 46 : 363 - 366
  • [7] Estimating the gas permeability of commercial volatile corrosion inhibitors at elevated temperatures with thermo-gravimetry
    Pieterse, Niel
    Focke, Walter W.
    Vuorinen, Eino
    Racz, Ilona
    CORROSION SCIENCE, 2006, 48 (08) : 1986 - 1995
  • [8] The corrosion behaviour of galvanized steel in cooling tower water containing a biocide and a corrosion inhibitor
    Minnos, Bihter
    Ilhan-Sungur, Esra
    Cotuk, Aysin
    Gungor, Nihal Dogruoz
    Cansever, Nurhan
    BIOFOULING, 2013, 29 (03) : 223 - 235
  • [9] Optimization and understanding of corrosion inhibitors for cooling water system
    Li, Zimin
    Zhu, Zilong
    Wang, Jianqiu
    Wang, Meng
    Hou, Ting
    Li, Qinghua
    Yu, Pei
    ANTI-CORROSION METHODS AND MATERIALS, 2023, 70 (05) : 259 - 267
  • [10] Investigation of the Corrosion Characteristics and Corrosion Inhibitor Action on J55 Steel in Produced Water
    Li, Wangdong
    Jing, Jiaqiang
    Sun, Jie
    Wang, Shuai
    Zhang, Feng
    Wang, Hai