Design and characterization of ionizing radiation-tolerant CMOS APS image sensors up to 30 Mrd (Si) total dose

被引:56
|
作者
Eid, ES [1 ]
Chan, TY
Fossum, ER
Tsai, RH
Spagnuolo, R
Deily, J
Byers, WB
Peden, JC
机构
[1] Photobit Technol Corp, Pasadena, CA 91101 USA
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[3] Sci Applicat Int Corp, Mclean, VA 22102 USA
关键词
active pixel sensor; CMOS active pixel sensor; CMOS APS; dark current; image sensor; imager; ionizing radiation; ionizing radiation-induced dark current; ionizing radiation-tolerant CMOS APS; radiation hard; radiation tolerant;
D O I
10.1109/23.983133
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An ionizing radiation-tolerant CMOS active pixel sensor (APS) image sensor test chip was designed employing the physical design techniques of enclosed geometry and P-channel guard rings. The test chip was fabricated in a standard 0.35-mum CMOS process that has a gate-oxide thickness of 7.0 nm. It was irradiated by a gamma-ray source up to a total ionizing radiation dose level of approximately 30 Mrd (Si) and was still functional. The most pronounced effect was the increase of dark current, which was linear with total dose level. The rate of dark current increase was about 1 to 2 pA/cm(2)/Krd (Si), depending on the design of the pixel. The results demonstrate that CMOS APS image sensors can be designed to be ionizing radiation tolerant to total dose levels up to 30 Mrd (Si). The fabrication process is standard CMOS, yielding a significant cost advantage over specialized radiation hard processes.
引用
收藏
页码:1796 / 1806
页数:11
相关论文
共 28 条
  • [21] Design of a radiation tolerant system for total ionizing dose monitoring using floating gate and RadFET dosimeters
    Ferraro, R.
    Danzeca, S.
    Brucoli, M.
    Masi, A.
    Brugger, M.
    Dilillo, L.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [22] Total Ionizing Dose Effects on a Radiation-Hardened CMOS Image Sensor Demonstrator for ITER Remote Handling
    Goiffon, Vincent
    Rizzolo, Serena
    Corbiere, Franck
    Rolando, Sebastien
    Bounasser, Said
    Sergent, Marius
    Chabane, Aziouz
    Marcelot, Olivier
    Estribeau, Magali
    Magnan, Pierre
    Paillet, Philippe
    Girard, Sylvain
    Gaillardin, Marc
    Marcandella, Claude
    Allanche, Timothe
    Van Uffelen, Marco
    Mont Casellas, Laura
    Scott, Robin
    De Cock, Wouter
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (01) : 101 - 110
  • [23] Total ionizing dose radiation effects in foue-transistor complementary metal oxide semiconductor image sensors
    Wang Fan
    Li Yu-Dong
    Guo Qi
    Wang Bo
    Zhang Xing-Yao
    Wen Lin
    He Cheng-Fa
    ACTA PHYSICA SINICA, 2016, 65 (02)
  • [24] Radiation-Hardening-by-Design with Circuit-Level Modeling of Total Ionizing Dose Effects in Modern CMOS Technologies
    Gorbunov, M. S.
    Zebrev, G. I.
    Osipenko, P. N.
    INTERNATIONAL CONFERENCE ON MICRO- AND NANOELECTRONICS 2009, 2010, 7521
  • [25] Multi-MGy Total Ionizing Dose Induced MOSFET Variability Effects on Radiation Hardened CMOS Image Sensor Performances
    Rizzolo, Serena
    Goiffon, Vincent
    Sergent, Marius
    Corbiere, Franck
    Rolando, Sebastien
    Chabane, Aziouz
    Paillet, Philippe
    Marcandella, Claude
    Girard, Sylvain
    Magnan, Pierre
    Van Uffelen, Marco
    Casellas, Laura Mont
    Scott, Robin
    De Cock, Wouter
    2017 17TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS), 2017, : 49 - 52
  • [26] Radiation-Hardened Library Cell Template and its Total Ionizing Dose (TID) Delay Characterization in 65nm CMOS Process
    Chang, Joseph S.
    Chong, Kwen-Siong
    Shu, Wei
    Lin, Tong
    Jiang, Jize
    Lwin, Ne Kyaw Zwa
    Kang, Yang
    2014 IEEE 57TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2014, : 821 - 824
  • [27] NOISE CHARACTERIZATION OF TRANSISTORS IN A 1.2-MU-M CMOS SOI TECHNOLOGY UP TO A TOTAL-DOSE OF 12-MRAD-(SI)
    FACCIO, F
    BIANCHI, M
    FORNASARI, M
    HEIJNE, EHM
    JARRON, P
    ROSSI, G
    BOREL, G
    REDOLFI, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) : 2310 - 2316
  • [28] Total Ionizing Dose and Single Event Latch-up Characterization of a 16-bit A-to-D Converter Fabricated in 0.18μm Triple-Well CMOS Process
    Zanchi, Alfio
    Hisano, Shinichi
    Hafer, Craig
    Kerwin, David B.
    2012 IEEE RADIATION EFFECTS DATA WORKSHOP (REDW), 2012,